HERC HAVEQUICK. Chief Warrant Officer Jim May III VMGR-452 Avionics Officer COM 845-563-2946 DSN 336-2946 Email - MayJH@mfr.usmc.mil 20 January 2003. HAVEQUICK. Anti-Jam Communication System Algorithm controlled Freq Hopping UHF only AM Line-of-Site (LOS) Jam-Resistant (Not Secure)

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'HERC HAVEQUICK' - bernad


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
herc havequick

HERC HAVEQUICK

Chief Warrant Officer Jim May III

VMGR-452 Avionics Officer

COM 845-563-2946 DSN 336-2946

Email - MayJH@mfr.usmc.mil

20 January 2003

havequick
HAVEQUICK
  • Anti-Jam Communication System
  • Algorithm controlled Freq Hopping
  • UHF only
  • AM Line-of-Site (LOS)
  • Jam-Resistant (Not Secure)
  • Plain or Secure Voice (with KY-58)
  • Developed by USAF
acronyms
ACRONYMS
  • HQ - HAVEQUICK (Active)
  • TOD - Time-of-Day (Mickey)
  • WOD - Word-of-Day
  • MWOD - Multiple WOD (Up to 6)
  • FMT - Frequency Managed Training
  • NET# - Network ID Number (Jump)
  • Op Day - Operational Day (Segment 7)
equipment
ARC-164 (RT-1505)

UHF Only

HAVEQUICK I/II form-fit replacement for KC-130 #2 ARC-159 (requires an adapter cable).

Built-in control panel.

2 Types of Control Panels:

Old - Manual display, Non-NVIS (Face plate can be changed out).

New - LCD display, NVIS compatible, Programmable with DTD.

Can be used with KY-58.

EQUIPMENT
equipment5
ARC-210 (RT-1556)

UHF/VHF.

HAVEQUICK I/II.

SINCGARS.

CDNU/RCU Control panels.

Programmable with DTD/AFP.

Can be used with KY-58.

Future RT-1794(C) and RT-1824(C) will have embedded COMSEC (Built-in KY-58).

EQUIPMENT

R/T

CDNU RCU

equipment6
DTD (CYZ-10)

AFP Software (PC to DTD).

CSEP (DTD Application)

Loads Regular Presets, AJ Presets (HQ/SINCGARS) and WODs (KAL-9200 Crypto) into ARC radio systems.

EQUIPMENT
terminology
TERMINOLOGY
  • TOD consists of two parts:
    • Precise Zulu Time: Hours, Minutes, Seconds, Sub-Micro-Seconds; synchronized time allows radios to frequency hop together.
    • Op-Day: Equal to the current calendar day (01-31), selects the active WOD when the radios has multiple WODs loaded (MWOD mode).
terminology8
TERMINOLOGY
  • TOD Types:
    • Preferred: (GPS-TOD) A precise TOD is passed from the internal aircraft GPS system once the system has a valid time.
    • Alternate: (Auto-TOD) A TOD passed from a such as a GPS Time Transmitter (Auto-Dog). Usually transmitted over a plain channel ship/station beacon every 15 seconds.
    • Other: A TOD passed from another user, only as accurate as the other user.
    • Self-Start/Emergency: Self-Starts radio clock to 00:00:00.000000. Must then manually enter the Op-Day and transmit this TOD to all other users or later receive a TOD update from another source.
terminology9

300.050

376.000

359.100

314.300

297.600

287.400

First Segment

TERMINOLOGY
  • WOD: Consists of 6 segments (36 digits) that “look like” UHF frequencies. It defines the frequency hopping dwell times and hopping rates (Net characteristics/pattern).

WOD Example

    • Segment 1: selects Combat or Training mode (300.0XX selects Training Mode), all others are Combat WODs.
    • Last 2 digits of the 1st Segment: Selects the Hop Rate.
    • Last 2 digits of the 2nd segment: Selects whether Conferencing Mode is enabled/disabled (00/50=Enabled, 25/75=Disabled, Training Mode is always in Conference Mode). Conference Mode: allows two net members to transmit simultaneously and be received by the remaining net members.
terminology10

300.050

376.000

359.100

314.300

297.600

287.400

05

Date Tag

TERMINOLOGY
  • MWOD: Simply a WOD with a Date Tag. A Date Tag is a two digit calendar day (01-31).

MWOD Example

    • Up to 6 MWODs can be preloaded into a radio, this allows seamless operation through rollover times (2400-0001Z).
    • The MWOD used by the radio is the MWOD whose Date Tag matches the Op-Day in the TOD.
    • An Op-Day is the actual mission/calendar day (01-31).
terminology11

HAVEQUICK WORD OF DAY (TRAINING ONLY) CONF US/ALLIED SEG 03

CH14/34 CH15/35 CH16/36 CH17/37 CH18/38 CH19/39 CH20/40 KAL ED REGNO

305.000 287.400 297.600 314.300 359.100 376.000 300.050 9200 C 225

Date Tag Seg 6 Seg 5 Seg 4 Seg 3 Seg 2 Seg 1 Key Info Key Data

TERMINOLOGY
  • Combat HQ Crypto: (KAL-9200 “Key-Tape”)
    • Segment 1: Decides the mode (Training/Combat).
    • Date Tag: Seg 7-300.000 = Date (305.000-300.000= Day 05).
    • All Segments: Control frequency hopping dwell times and hopping rates.
    • Combat WODs: Only authorized for wartime use. Classified Confidential Non-COMSEC CMS material.

SAMPLE KAL-9200 KEY-TAPE

terminology12
TERMINOLOGY
  • FMT: Frequency Managed Training Table, the actual frequencies (Hop Set) that make up the Training Net (T-Net).
    • HQ I Training mode: Contains 5 FMT Table (Last 5 Seg of WOD).
    • HQ II Training mode: Contains 16 FMT Table (Below).
    • HQ II Combat Mode: Contains nearly unlimited combinations of Hop Sets, only authorized for actual wartime.
    • CONUS approved FMT Table: normally already defaulted in the radio:

HQII (16 FMT - CONUS)

HQI (5 FMT) F1 – 235.050 F9 – 314.450

F1 – XXX.XXX F2 – 225.150 F10 – 308.750

F2 – XXX.XXX F3 – 252.925 F11 – 303.275

F3 – XXX.XXX F4 – 239.950 F12 – 298.650

F4 – XXX.XXX F5 – 271.950 F13 – 293.550

F5 – XXX.XXX F6 – 267-850 F14 – 289.050

F7 – 262.450 F15 – 284.150

F8 – 257.250 F16 – 279.750

terminology13
TERMINOLOGY
  • NET: A group of frequencies that is used for synchronized frequency hopping during HAVEQUICK operations.
    • Combat Mode: 1000 possible Nets (000-999)
    • Training Mode: 5 possible Nets in HQI (000-004)

16 possible Nets in HQII (000-015)

terminology14
TERMINOLOGY
  • NET#: Determines the order in which the radio will hop among the frequencies, has the following form:

AXX.XYY

    • In Combat Mode: XX.X = 00.0 - 99.9 (1000 Nets), frequency tables used are:
      • AXX.X00 HQ I
      • AXX.X25 HQ II NATO (Europe)
      • AXX.X50 HQ II Non-NATO (Non-Europe/War Reserve)
      • AXX.X75 Reserved for HQ IIa (Saturn)
    • In Training Mode (T-Net):
      • AXX.X00 HQ I, XX.X = 00.0 - 00.4 (5 T-Nets), 5 FMT specified by the training WOD.
      • AXX.X25 HQ II, XX.X = 00.0 - 01.5 (16 T-Nets), 16 FMT Table used.
terminology15
NET# Formats: (Example is NATO Net 452)

AXX.XYY (A45.225)

A: Operational

XX.X: Net# (23.9 = Net 452)

YY: NATO (Europe)

XXX.0YY (452.025)

XXX: Net# (239 = Net 452)

0: Not Used

YY: NATO (Europe)

3XX.XYY (345.225)

3: Operational/Active

XX.X: Net# (23.9 = Net 452)

YY: NATO (Europe)

TERMINOLOGY

A45.225

  • AFP, KC-130
  • F/A-18
  • EA-6, F-14, S-3

452.025

345.225

hq basics

Continuously Changing Variable

FREQ TABLES

TOD

FREQ TABLES

Op-Day Selects MWOD

TIME

20:30

OP-DAY

07

FREQ TABLES

MWOD

212.025

322.050

262.000

312.025

342.025

212.000

04

MWOD

312.025

245.025

322.000

232.025

282.025

392.000

05

MWOD

378.050

354.050

232.050

312.025

342.025

298.000

06

MWOD

212.025

322.050

262.000

312.025

342.025

212.025

07

MWOD

342.025

322.050

262.000

312.025

292.025

262.000

08

MWOD

242.025

322.050

372.050

312.025

342.025

362.050

09

20:23 345.250 234.252

20:24 321.215 328.235

20:25 374.250 200.845

20:26 301.250 336.125

20:27 374.250 200.845

20:28 321.215 328.235

20:29 324.250 210.845

20:30 301.250 336.125

20:31 321.215 328.235

20:32 374.250 200.845

20:33 301.250 336.125

20:34 374.250 200.845

20:35 301.250 336.125

20:36 374.250

Date Tag

NET#

A01.225

Transmits/Receives

on Freq 301.250

for specified time

HQ BASICS

MWOD’s allow the radio to automatically switch to the next WOD when rollover occurs at 2400Z, this eliminates “Mid-Night Madness” and allows seamless operation throughout a mission.

comm requirements

RADIO 1

    • TOD
    • WOD
    • FMT Table
    • NET#
  • RADIO 2
    • TOD
    • WOD
    • FMT Table
    • NET#
COMM REQUIREMENTS

COMMUNICATION

  • TOD, WOD, Net# and FMT Table (Hop Set) MUST ALL be identical for communication to take place between radios.
arc 164 setup
Command Codes:

Six-digit programming codes that allow the user to program and setup the ARC-164 radio system.

Activated by entering the specific code in Preset Channel 20.

When activated, they act as additional switches.

COMMAND MODE

FUNCTION

220.000

Verify/Operate

220.025

MWOD Load

220.050

MWOD Erase

220.075

FMT-Net Load

ARC-164 SETUP
arc 164 setup19
Initialize (Verify/Operate):

Set Function Selector to MAIN or BOTH.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

2

5

0

3

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup20
Initialize (Verify/Operate):

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

2

5

0

3

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup21
Initialize (Verify/Operate):

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

5

0

3

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup22
Initialize (Verify/Operate):

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup23
Initialize (Verify/Operate):

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Lift access cover and press Red PRESET button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup24
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

2

5

0

3

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup25
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

2

5

0

3

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup26
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

5

0

3

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup27
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

25

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup28
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

25

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup29
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

25

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup30
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

3

0

0

0

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup31
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

3

0

0

0

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup32
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

19

PRESET

3

0

0

0

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup33
Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

Set Frequency switches to 2nd Segment (376.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

19

PRESET

3

6

0

7

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup34
Press TONE button (single beep).

Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

Set Frequency switches to 2nd Segment (376.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

19

PRESET

3

6

0

7

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup35
Press TONE button (single beep).

Set CHAN to 18.

Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

Set Frequency switches to 2nd Segment (376.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

18

PRESET

3

6

0

7

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup36
Press TONE button (single beep).

Set CHAN to 18.

Set Frequency switches to 3rd Segment (359.100).

Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

Set Frequency switches to 2nd Segment (376.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

18

PRESET

3

9

1

5

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup37
Press TONE button (single beep).

Set CHAN to 18.

Set Frequency switches to 3rd Segment (359.100).

Press TONE button (single beep).

Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

Set Frequency switches to 2nd Segment (376.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

18

PRESET

3

9

1

5

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup38
Press TONE button (single beep).

Set CHAN to 18.

Set Frequency switches to 3rd Segment (359.100).

Press TONE button (single beep).

Set CHAN to 17.

Load WOD/MWOD:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.025 (MWOD Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to 1st Segment (300.050).

Press TONE button (single beep).

Set CHAN to 19.

Set Frequency switches to 2nd Segment (376.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

17

PRESET

3

9

1

5

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup39
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

17

PRESET

3

1

00

4

3

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup40
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

17

PRESET

3

1

00

4

3

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup41
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

16

PRESET

3

1

00

4

3

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup42
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

16

PRESET

2

9

00

7

6

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup43
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

16

PRESET

2

9

00

7

6

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup44
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

15

PRESET

2

9

00

7

6

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup45
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

15

PRESET

2

8

00

7

4

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup46
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

15

PRESET

2

8

00

7

4

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup47
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

Press TONE button (single beep).

Set CHAN to 14.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

2

8

00

7

4

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup48
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

Press TONE button (single beep).

Set CHAN to 14.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup49
Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

Press TONE button (single beep).

Set CHAN to 14.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

Press TONE button (double beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup50
To Load additional MWODs, return to Channel 20 and repeat loading procedure.

Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

Press TONE button (single beep).

Set CHAN to 14.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

Press TONE button (double beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup51
To Load additional MWODs, return to Channel 20 and repeat loading procedure.

Radio will retain the 6 most recent WODs loaded in non-volatile memory and are retained when the radio is turned off.

Load WOD/MWOD (Cont):

Set Frequency switches to 4thSegment (314.300).

Press TONE button (single beep).

Set CHAN to 16.

Set Frequency switches to 4th Segment (297.600).

Press TONE button (single beep).

Set CHAN to 15.

Set Frequency switches to 5th Segment (287.400).

Press TONE button (single beep).

Set CHAN to 14.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

Press TONE button (double beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup52
Verify WOD Storage:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

3

OFF ON

SQUELCH

5

TONE

4

CHAN

20

PRESET

1

2

2

0

0

00

2

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup53
Verify WOD Storage:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup54
Verify WOD Storage:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000), set CHAN switch Momentarily to 19 and return to 20, a single beep indicates WOD for that day is loaded (No beep, No WOD stored), repeat this step for each day to be verified.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP

19

arc 164 setup55
ARC-164 SETUP
  • TOD Info:
    • Ensure you are in Operate Mode when performing TOD functions.
    • The ARC-164 will automatically accept the first valid TOD signal it receives and reject subsequent TODs unless an update action is initiated.
    • A TOD update may be necessary when incoming transmissions from several different radios sound garbled.
    • It is possible to receive a TOD in both normal and active modes.
    • The purpose of passing a TOD in active mode is to easily allow a minor update due to radio drifting out of synchronization.
    • If your TOD has drifted too much, a TOD update in active mode may not be possible.
arc 164 setup56
TOD Receive:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

3

OFF ON

SQUELCH

5

TONE

4

CHAN

20

PRESET

1

2

2

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup57
TOD Receive:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Set Frequency switches to TOD broadcast frequency (Auto-Dog frequency or another users frequency).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

3

8

0

5

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup58
TOD Receive:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Set Frequency switches to TOD broadcast frequency (Auto-Dog frequency or another users frequency).

Turn the A-3-2-T knob to “T” momentarily and return to prior selection (You have now opened a 60 window to receive a TOD, if no TOD is received the window closes and “T” will need to be reselected).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

T

8

0

5

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup59
TOD Receive:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Set Frequency switches to TOD broadcast frequency (Auto-Dog frequency or another users frequency).

Turn the A-3-2-T knob to “T” momentarily and return to prior selection (You have now opened a 60 window to receive a TOD, if no TOD is received the window closes and “T” will need to be reselected).

On set frequency, wait for Auto-Dog (10-15 seconds) or request a “Mickey” from other user, a short beep will indicate a TOD was received.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

3

5

00

8

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup60
ARC-164 SETUP
  • TOD Check (Confirm):
    • To confirm that a TOD has been received:
      • Re-tune the radio to another frequency (to preclude transmitting a non-common TOD to another user).
      • Press and hold TONE button.
      • Listen for TOD and Tone signal
      • If you hear a only a standard tone, the radio has not received a TOD.
      • If you hear a TOD signal followed by a standard tone, the radio has received a TOD.
    • The TOD check will assume that some time is loaded, but the only way to determine if it is the correct time is to go active and try a talk test.
arc 164 setup61
TOD Send:

Establish radio contact/receive request.

Press the TONE button to transmit TOD with in 60 seconds of receiver’s request.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

3

8

0

5

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup62
ARC-164 SETUP
  • TOD (Self-Start/Emergency):
    • NOT RECOMMENDED, Only use as a last resort.
    • Will not be able to transmit/receive in Active Mode to users on a “Real-Time” synchronized system until TOD is updated from a “Real-Time” source (Auto-Dog/User with true GPS/Zulu Time).
    • Self-Starts require the Op-Day to be entered, since a Self-Start only restarts the radios clock to 00:00:00.000000 (no Date Tag).
    • Op-Day is not required to be entered with a normal TOD, since the Date Tag is included in a TOD.
arc 164 setup63
TOD (Self-Start/Emergency):

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

3

OFF ON

SQUELCH

5

TONE

4

CHAN

20

PRESET

1

2

2

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup64
TOD (Self-Start/Emergency):

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Turn the A-3-2-T knob to “T” and hold.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

T

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup65
TOD (Self-Start/Emergency):

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Turn the A-3-2-T knob to “T” and hold.

Press TONE button while holding A-3-2-T at “T” position (no tone signal will be heard), release knob and button.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

T

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup66
TOD (Self-Start/Emergency):

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

Turn the A-3-2-T knob to “T” and hold.

Press TONE button while holding A-3-2-T at “T” position (no tone signal will be heard), release knob and button.

To confirm radio has TOD, press and hold TONE button (listen for TOD signal followed by a short tone).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

00

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup67
Entering Op-Day is only required for Self-Starts.

Only use this function to manually select an MWOD.

Select Current Op-Day:

After all WODs and their Date Tags have been entered, the current Op-Day must be loaded.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup68
Entering Op-Day is only required for Self-Starts.

Only use this function to manually select an MWOD.

Select Current Op-Day:

After all WODs and their Date Tags have been entered, the current Op-Day must be loaded.

This date is loaded into volatile memory and will be lost when the radio is turned off.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

14

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup69
Entering Op-Day is only required for Self-Starts.

Only use this function to manually select an MWOD.

Select Current Op-Day:

After all WODs and their Date Tags have been entered, the current Op-Day must be loaded.

This date is loaded into volatile memory and will be lost when the radio is turned off.

While in still in MWOD Load Mode, Set CHAN to 01.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup70
Entering Op-Day is only required for Self-Starts.

Only use this function to manually select an MWOD.

Select Current Op-Day:

After all WODs and their Date Tags have been entered, the current Op-Day must be loaded.

This date is loaded into volatile memory and will be lost when the radio is turned off.

While in still in MWOD Load Mode, Set CHAN to 01.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup71
Entering Op-Day is only required for Self-Starts.

Only use this function to manually select an MWOD.

Select Current Op-Day:

After all WODs and their Date Tags have been entered, the current Op-Day must be loaded.

This date is loaded into volatile memory and will be lost when the radio is turned off.

While in still in MWOD Load Mode, Set CHAN to 01.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup72
Entering Op-Day is only required for Self-Starts.

Only use this function to manually select an MWOD.

Select Current Op-Day:

After all WODs and their Date Tags have been entered, the current Op-Day must be loaded.

This date is loaded into volatile memory and will be lost when the radio is turned off.

While in still in MWOD Load Mode, Set CHAN to 01.

Set Frequency switches to DATE TAG in format 3XX.000 (January 5 = 305.000).

Press TONE button (single beep).

After completing MWOD’s and/or Op-Day Loading, ensure you place the radio back into Operate Mode using the prior listed Initialization procedure (Verify/Operate 220.000).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

01

PRESET

3

0

00

5

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup73
ARC-164 SETUP
  • Active Mode Info:
    • WOD and TOD may be entered in any order once the radio is turned on.
    • When entering Active mode, a STEADY Tone is heard in the headset if TOD has not been initially received, Op-Day not entered for Self-Start/Emergency Mode or a WOD has not been entered.
    • When entering Active mode, an INTERRUPTED tone is heard in the headset when an incorrect Net# is selected.
    • You can select/store a Net# the same as a regular Preset and Manual frequency.
arc 164 setup74
Selecting Net#:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

WOD/MWOD Entered.

TOD Received (Set Op-Day if Self-Start/Emergency).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

3

OFF ON

SQUELCH

5

TONE

4

CHAN

20

PRESET

1

2

2

0

0

00

2

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup75
Selecting Net#:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

WOD/MWOD Entered.

TOD Received (Set Op-Day if Self-Start/Emergency).

Set Manual-Preset-Guard Selector to MANUAL.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

2

00

0

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup76
Selecting Net#:

Ensure you are in Verify/Operate Mode:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.000 (Verify/Operate).

Press Red PRESET button (single beep).

WOD/MWOD Entered.

TOD Received (Set Op-Day if Self-Start/Emergency).

Set Manual-Preset-Guard Selector to MANUAL.

Turn the A-3-2-T knob to “A”, set frequency switches to required Net# and transmit as usual.

Example shown is NATO Net# 014

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

A

0

25

1

4

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup77
Erase MWODs from Memory:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

3

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

1

2

2

50

5

0

3

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup78
Erase MWODs from Memory:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.050 (MWOD Erase).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup79
Erase MWODs from Memory:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.050 (MWOD Erase).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

1

TONE

CHAN

20

PRESET

3

2

2

2

50

0

0

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup80
Erase MWODs from Memory:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.050 (MWOD Erase).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Press TONE button (single beep).

All MWODs are erased, Active Mode is disabled until MWODs are reloaded, return to Verify/Operate mode to operate radio in regular mode.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

2

0

0

2

50

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup81
Load FMT-Net Frequencies:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

3

OFF ON

SQUELCH

TONE

CHAN

20

PRESET

1

2

2

50

5

0

3

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup82
Load FMT-Net Frequencies:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.075 (FMT-Net Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

2

TONE

1

CHAN

20

PRESET

3

2

75

0

0

2

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup83
Load FMT-Net Frequencies:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.075 (FMT-Net Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Ensure CHAN is still set to 20.

Set Frequency switches to 1st FMT training frequency (235.050).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

1

OFF ON

SQUELCH

TONE

2

CHAN

20

PRESET

3

2

50

5

0

3

A

3

2

T

.

EMB

ARC-164 SETUP
arc 164 setup84
Continue decreasing CHAN by 1, entering frequencies and pressing TONE button until all 16 are loaded (like MWOD entry).

Return to Verify/Operate Mode.

Load FMT-Net Frequencies:

Set Function Selector to MAIN or BOTH.

Set Manual-Preset-Guard Selector to PRESET.

Set CHAN to 20.

Set Frequency switches to 220.075 (FMT-Net Load).

Press Red PRESET button (single beep).

Set Manual-Preset-Guard Selector to MANUAL.

Ensure CHAN is still set to 20.

Set Frequency switches to 1st FMT training frequency (235.050).

Press TONE button (single beep).

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

1

OFF ON

SQUELCH

TONE

2

CHAN

19

PRESET

3

2

2

50

5

1

A

3

2

T

.

EMB

ARC-164 SETUP
herc havequick85
HERC HAVEQUICK

QUESTIONS?

backups

CHAN FREQ/NET/TIME

8 8

SHQIIa

FAULT

888 : 888

V/U

H

F

LOAD

OFST

TIME AM H SND LE

GPSFM L RCVOFFST

TR+G

TEST TR

OFF ADF

ZRO CHNG

(PULL) PRST

PRST

MAR MAN

AJ 243

AJ/M 121

(PULL) (PULL)

CHAN/FREQ

CRSR

PUSH

MAIN

VOL

PRESET

OFF BOTH

MANUAL GUARD

UHF

ADF

OFF ON

SQUELCH

TONE

VOL

CHAN

01

PRESET

2

50

0

5

3

A

3

2

T

.

EMB

BACKUPS