CHAPTER 5 THE X-RAY IMAGING SYSTEM

CHAPTER 5 THE X-RAY IMAGING SYSTEM SPECIFIC OBJECTIVES NOTED IN THIS POWER POINT BEGIN ON PAGE 90-101. Four timers. 1) Synchronous-min time is 1/60. Increase in equal multiples 2) Electronic-most accurate/controlled by microprocessor Where are 1 and 2 located in the circuit?

Download Presentation

CHAPTER 5 THE X-RAY IMAGING SYSTEM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CHAPTER 5 THE X-RAY IMAGING SYSTEM SPECIFIC OBJECTIVES NOTED IN THIS POWER POINT BEGIN ON PAGE 90-101.

  2. Four timers • 1) Synchronous-min time is 1/60. Increase in equal multiples • 2) Electronic-most accurate/controlled by microprocessor • Where are 1 and 2 located in the circuit? • mAs time and falling load generator-let’s discuss this! (Page 90)

  3. AEC pg 92 Bushong, Chapter 8, Fauber • WHAT IS THE PURPOSE OF AN AEC? • HOW DO YOU USE THEM WHEN POSITIONING? • CHAMBERS VS. PHOTOMULTIPLIERS • Can they produce the same density of radiograph for any size patient?

  4. Ion chamber vs photomultiplier or photodiode • Collects a charge via light • Sequence • X-ray • Patient • Special cassette • photodiode • Waits for a charge • Sequence • X-ray • Patient • Ion chamber • IR

  5. Anatomically Programmed Radiography • APR • Page 211 Fauber

  6. High Voltage Transformer • What do you remember?

  7. RECTIFICATION, Bushong 93 • Unrectified • Half wave rectified • Fully rectified

  8. Phases Voltage Ripplepage 26 Fauber figure 2-13, Bushong, pg 97,99 • 100% • 13 or 14% • 3 or 4% • Less than 1% • Single • Three phase • Three phase/6 pulse • Three phase/12 pulse • High Frequency • How do these phases impact technique??

  9. POWER RATING • UNIT OF MEASUREMENT OF POWER IS WATTS • AMPS MEASURES THE QUANTITY OR QUALITY? • Volts measures the ________________________ • Amps=current • Volts = potential • Try this problem: If your kitchen is on a 25 amp circuit breaker and 110 volts is the available voltage what is the maximum watts this circuit can handle? • ON TO CHAPTER SIX!!

  10. CHAPTER SIX, Bushong • REVIEW THE PROTECTIVE HOUSING • Let’s dissect the cathode • What happens at the cathode? • Focusing cup • Imbedded in cathode • Two (page 13 in fauber, figure 2-1) • Confines the electron beam • Grid controlled tubes • Allows for tube to be turned off and on quickly • Space charge and space charge effect • High mAs and low kVp can be space charge limited..why?

  11. The Anode • Three functions of the anode -What do you know already about the anode • The target • What does the rotor do? • Note: please skip induction motors at this time

  12. Focal spot, line focus principle and anode heel effect, Bushong, 107-115,Fauber 23-32 • Focal spot and target angle (Fauber pg 31 figure 2-2) • The smaller focal spot • More concentration of heat • Better detail • Usually located in the smaller angle • Large focal spot • Less concentration of heat • Less detail • Larger angle • Page 32 Fauber, figure 2-18

  13. Line Focus Principle • Effective focal spot size is always smaller than the actual focal spot size • Fauber-pg 31 figure 2-16, figure 2-17

  14. Anode Heel effect • Bushong pg 130, pg 7-20 • The heel effect is more or less with a greater angle? • Which side has greatest intensity? • Off Focus radiation

  15. How is heat dissipated in the tube? • Tube rating charts • Heat units • Anode cooling charts