First Page

First Page. Design, Manufacture, Transport and Integration on-site in Chile of ALMA Antennas UPS Uninterruptible Power Supply PM#05 20-21 Jun 2006. Power Requirements. Antenna UPS Power Requirements 15 KVA , 400 VAC, 50 Hz, 10 minutes

balin
Download Presentation

First Page

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. First Page • Design, Manufacture, Transport and Integration on-site in Chile of ALMA Antennas • UPS • Uninterruptible Power Supply • PM#05 20-21 Jun 2006

  2. Power Requirements • Antenna UPS Power Requirements • 15 KVA , 400 VAC, 50 Hz, 10 minutes • UPS Dimensioning due to the critical environmental conditions and altitude requirements. • 30 KVA , 400 VAC, 50 Hz, 10 minutes

  3. Location Details • Location Details UPS Main Unit (U1) UPS Batteries Unit (U2)

  4. U1 Dimensions • UPS Main Unit (U1) Dimensions 800 mm 900 mm 1200 mm

  5. U2 Dimensions • UPS Batteries Unit (U2) Dimensions 968 mm 800 mm 1900 mm

  6. UPS Choise 1 UPS Baseline Proposal World Wide Group Brand

  7. UPS Choise 2 UPS Choice Brand : Liebert Model :NX (30KVA,24KW)

  8. UPS characteristics UPS characteristics • Liebert NX has: • True on line with double conversion: It delivers 100% protection, full separation between Input and Output, Power regeneration. • DSP Control : Digital Signal Processor supply full stability control in the years. • Rectifier with sinusoidal absorption with PFC Vector Control (power factor correction). • THD < 3%. • Power Factor >= 0,99. • Full tolerance to the grid floatation : from 305 to 477 V and from 40 to 70 Hz. • Ripple < 5%.

  9. UPS Batteries1 UPS Batteries - Baseline Proposal NorthStar NSB 40 High cycle life capability +500 C/3 @ 80% DOD 10 Years float life at 25°C. 15 years at 20°C Flame retardant 3 step terminal seal

  10. UPS Batteries2 UPS Batteries NorthStar NSB 40 20 Hour capacity: 41Ah to 1.80 VPC 15 minut power: 194 W/cell to 1.67 VPC Float recharge 2.29 @20°c Cyclic recharge 2.45 VPC @ 25°, no current limit