1 / 4

metaldyne corporation korea 귀중

metaldyne corporation korea 귀중. Tau- ENG FIELD NOISE 발생품 이음 재현시험 결과. Tau -ENG . WATER PUMP NOISE 발생품의 이음 재현 시험시의 녹취음에 대하여 주파수 분석을 실시하였으므로 그 결과를 보고 드립니다. 2010 年 12 月 29 日 NEK 주식회사 품질보증 부. 작성. 조사. 승인. 1.Tau-ENG NOISE 발생 WATER PUMP 재현시험 결과. (1) 현품 이력. (2) 이음재현시험조건.

Download Presentation

metaldyne corporation korea 귀중

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. metaldyne corporation korea 귀중 Tau-ENGFIELD NOISE 발생품 이음 재현시험 결과 Tau-ENG.WATER PUMP NOISE 발생품의 이음 재현 시험시의 녹취음에 대하여 주파수 분석을 실시하였으므로 그 결과를 보고 드립니다 2010年12月29日 NEK주식회사 품질보증부 작성 조사 승인

  2. 1.Tau-ENG NOISE 발생 WATER PUMP 재현시험 결과 (1) 현품 이력 (2) 이음재현시험조건 ・ 시험기: metaldyne korea WP내구 시험기 ・ 회전수(rpm) : 500,1000,1500,2000 ・시험액 : HMC순정 LLC 50% 수용액 (3) 시험결과 주파수 분석결과 6000Hz 영역에서 이음으로 판단되는 주파수 PEAK 가 확인 되었습니다만 , 정상품과 고품의 주파수 PEAK 가 동일한 것으로부터 이음특징으로 확인된 6000Hz영역의 주파수 PEAK는 WP 내구시험기의 이음특징(PEAK)인 것으로 판단됩니다.

  3. 1.Tau-ENG NOISE 발생 WATER PUMP 재현시험 결과 (4) 주파수 분석결과 1000Hz 1000Hz 18000Hz 6000Hz 12000Hz 18000Hz 6013Hz 12000Hz 8994Hz 9019Hz 15013Hz 15006Hz 1000Hz 5988Hz 1000Hz 6006Hz 11988Hz 17994Hz 12025Hz 17994Hz 8975Hz 15019Hz 8975Hz 15019Hz

  4. 1.Tau-ENG NOISE 발생 WATER PUMP 재현시험 결과 (4) 주파수 분석결과 994Hz 1000Hz 5975Hz 11981Hz 5975Hz 17981Hz 12040Hz 17981Hz 8937Hz 15025Hz 8963Hz 15025Hz 1000Hz 11969Hz 1000Hz 5969Hz 17975Hz 11969Hz 5969Hz 8950Hz 17981Hz 15025Hz 8950Hz 14994Hz

More Related