Evolution range Line-Interactive UPS 650 to 3000VA

Evolution range Line-Interactive UPS 650 to 3000VA. Evolution at a glance. Best-in-class Line interactive UPS range from 650 VA to 3kVA fully featured (Switched outlets, density-optimized rack versions, 0.9 PF & EXB on S versions) multiple form factors innovative connectivity

xenia
Download Presentation

Evolution range Line-Interactive UPS 650 to 3000VA

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Evolution range Line-Interactive UPS650 to 3000VA

  2. Evolution at a glance • Best-in-class Line interactive UPS range from 650 VA to 3kVA • fully featured (Switched outlets, density-optimized rack versions, 0.9 PF & EXB on S versions) • multiple form factors • innovative connectivity • Replacement for Pulsar Evolution • Designed to match requirementsof most channels • Distribution • Large roll outs • OEM / Key Accounts

  3. Evolution AFT positioning Customer Expectations MGE Product Features • (Manual) Maintenance ByPass optional • From 2 to 4 PowerShare outlets • Superior power management • Hot-swappability • Receptacles remote mamagement • Reduce MTTR, management Availability • Fits in my physical environment • Simple cabling/install • Simple to manage • Fits with my SW choices • Choice of rack formats or tower • Rack accessories: PDU ’s/local outlets… • High perf. LAN (SNMP/HTTP/SSL..) • Wide OS, NMS range support Flexibility • Easy maintenance • No hidden costs • Keep installation in « top shape » • Transverse maintenance by-pass • Free rack rails (rack & RT models) • Complete range of services… TCO In red: MGE differenciators

  4. New Evolution Line Interactive range Evolution 650VA420W 850VA600W 1150VA770W 1550VA1100W 2000VA1600W Tower use Rack use RT2U short depth Evolution S 1250VA1150W 1750VA1600W 2500VA 2250W 3000VA2700W RT versatile Tower- optimized S Range features:- 0.9 PF- EXB compatible- RT format RT3U Short RT versatile rack- optimized RT2U short depth RT2U Long depth RT2U short depth RT2U Long

  5. Availability : Line-interactive topology • Best price/perfomance ratio for the protection of Win/Linux servers, network devices, storage systems. • Extended input voltage tolerance • Evolution input voltage window : 160 V to 294 V** (can be adjusted to 150 V- 294V)

  6. HotSwap MBP 4FR Availability : Hot-Swappability • UPS Hot-Swappability • HotSwap MBP (HotSwap Maintenance By-Pass) allows for easy UPS replacement without interruption for the load • Battery Hot-Swappability • Hot-Swappable batteries allow replacement without interruption for the load (from front panel, no need to remove UPS from rack) • Benefits : • Service continuity in all situations • during battery replacement • while replacing a faulty unit • while upgrading for a new UPS

  7. Availability : HotSwap MBP architecture • The best architecture for easy Hot Swappability today and tomorrow • external MBP using standard IEC connector for power I/O connection to the UPS => can be used with any UPS available from stock • no need for dedicated electronic or UPS module • Benefits : • True compatibility with any UPS models • within MGE current range • from one generation to another • even also with UPS from competition (but transfer without break not guaranteed) • Better MTTR • Swap can be made with any standard UPS

  8. Powershare 1 and 2 Availability : Powershare = Individual outlet control • Extend backup time Shutdown non-critical equipment when on battery to provide maximum runtime on critical equipment • Save time & money through remote reboot Restart locked equipment by remotely switching off & on UPS outlets • Ensure safe restart of the computer systems start up IT equipment sequentially (firewall first, ….) avoid overload due to simultaneaous start-up of many devices

  9. Runtime at 70% of rated power in VA UPS + 1 EXB + 2 EXB + 3 EXB + 4 EXB 1250 14 min 60 min 100 min 140 min 200 min 9 min 36 min 60 min 90 min 120 min 1750 2500 11 min 55 min 90 min 200 min 140 min 3000 10 min 42 min 75 min 100 min 135 min Availability : Evolution Sextended runtime with up to 4 EXB Evolution S EXB : • 2U short depth for Evolution S 1250/1750 • 3U short deph for Evolution S 2500/3000

  10. Rack 1U Tower RT Flexibility : form factors • 3 form factors available for easy integration • Tower: cost-optimized for traditional use up to 1550 VA • Rack 1U: Density-optimized for rackmounting (1550VA in 1U) • RT: Rack/Tower versatile (all accessories supplied) • Density optimized (2U Long) • Tower and Short-depth racks (3U and 2U Short) • Benefits : • optimized coverage of market needs • all kinds of rack-mounted applications • classical office environment

  11. FlexPDU (8 DIN model) HotSwap MBP (6 IEC model) Flexibility : I/O connections • FlexPDUs and HotSwap MBPs • 2 ranges of accessories for easy connections of the protected equipment • PDUs with local or IEC outlets • External By-pass with outlets or terminal blocks • Benefits : • allow easy connectivity of all kinds of equipment • whatever the input type (local plugs, IEC or terminal blocks) • whatever the criticity (choose HotSwap MBP for service continuity) • whatever the space constraints (see mounting possibilities)

  12. Flexibility :integration on all MGE «RT» UPSs • On rear panel of 3Umodels • both in tower mode orrack mode • On top • Left or righton 2U and 3U models • minimise total depth

  13. Flexibility : communications • USB + RS232 Serial + Slot for Management Card or USB Serial/Contacts • Benefits : • compatibility with the installed base of today and tomorrow • USB for Windows/MacOS/Linux • Serial still used with NT/ old Linux / Unix and by integrators • wide choice of remote management solutions, whetherSNMP/Web-based (Networks) or contact-based (Telco, BMS, buzzer,…..) or ModBus/Jbus (Industry) Slot for : - NMC Minislot 2006 Edition(1) (1) = included in Evolution S Netpack versions - Management Card Contacts/Serial (for a 2ndcontacts port) - NMC ModBus/Jbus (2) (2) available end of 2006

  14. RPO + ROO connectors Flexibility : communications • Built-in Remote control RPO = Remote Power Off : for use with emergency stop button (RPO reset is required for restart) • Note : doesn’t open battery breaker • ROO = Remote ON/OFF : for use to duplicate remotely the ON/OFF button (UPS in a non-accessible trolley/closet/shelter, …..) • Benefits : • meets OEM/ specific project requirements with standard product

  15. Network integration Local monitoring HP OpenView IBM Netview CA Unicenter HP Insight Manager USB or Serial Personal Solution-Pac Network Management Card 2006 Edition Remote display UPS control Web-based monitoring from any Internet browser TCO : easily manageable

  16. Evolution vs APC Comments Evolution Smart-UPS Evolution vs Smart-UPS 0.65-0.85-1.15-1.55-2 kVA 0.75-1-1.5-2.2-3-5 kVA Format 650-1550 VA: Tower or Rack Tower or Rack 2000 VA: Convertible U height 650-1550 VA: 1U 750-1000 VA: 1U 2000 VA: 2U 1500-2200 VA: 2U  Compatible with 600 mm depth cabinet From 750 to 1500 VA Maintenance bypass 0 U, HotSwap MBP From 2.2 kVA Hot-swappable Battery: In standard In standard100% hot-swappable Electronic: HotSwap MBP From 2.2 kVA Optional local outlets FlexPDU: FR, DIN, BS, IEC PDU: IECHotSwap MBP: FR, DIN, BS, IEC, HW Maintenance Bypass: IEC  Switched outlets No Optimal use of EXB  Emergency Power OFF (RPO) From 2.2 kVA RackRemote ON/OFF (RPOO) No   Rack kit included Option: 100 € Communication USB, RS232, contacts USB, RS232 Number of references 9 10 U input range 100% load: 160-294 V 100% load: 160-286 V Interface LED LED PF (VA/W) 650-1550 VA: 0.7 750-1500 VA: 0.7 2000 VA: 0.8 2200 VA: 0.9 Standard outlets Tower and RackTowerRack 650-850 VA: 4 IEC10A 750 VA: 6 IEC10A 4 IEC10A 1.15-1.55 kVA: 4 IEC10A 1-1.5 kVA: 8 IEC10A 4 IEC10A 2 kVA: 8 IEC10A 2.2 kVA: 9 IEC10A 9 IEC10A Runtime 1150 VA @ 670 W: 5 min 1000 VA @ 670 W: 6.1 min1550 VA @ 980 W: 6 min 1500 VA @ 980 W: 6.7 min 2000 VA @ 1600 W: 5 min 2200 VA @ 1600 W: 8 min

  17. Evolution S vs APC long runtime Comments Evolution S Smart-UPS XL & XL Modular Evolution S vs Smart XL 1.25-1.75-2.5-3 kVA 0.75-1-1.4-1.5-2.2-3-5 kVA Number of references UPS: 5 13 Less references for aPacks EXB: 2 9 similar offer Format Convertible 1-3 kVA: Tower 1.4-3 kVA: Rack 1.5-3 kVA: Convertible  Compatible with 600 mm depth cabinet From 1.4 to 2.2 kVA Maintenance bypass 0 U, HotSwap MBP From 2.2 kVA Hot-swappable Battery: In standard In standard100% hot-swappable Electronic: HotSwap MBP From 2.2 kVA Optional local outlets FlexPDU: FR, DIN, BS, IEC PDU: IECHotSwap MBP: FR, DIN, BS, IEC, HW Maintenance Bypass: IEC  Switched outlets With XL Modular Optimal use of EXB1.5 and 3 kVA  Emergency Power OFF (RPO) OptionRemote ON/OFF (RPOO) No  U height 1.25-3 kVA: 2U 1.5-3 kVA: 2U 3 kVA: 3U 1.4-3 kVA: 3U 2.2: 5U U input range 100% load: 160-294 V 100% load: 160-286 V PF (VA/W) 0.9 0.73 to 0.95 Standard outlets 1.25 kVA: 8 IEC10A 1-1.4 kVA: 8 IEC10A 1.75 kVA: 8 IEC10A 1.5 kVA: 9 IEC10A 2.5-3 kVA: 8 IEC10A + 1 IEC16A 2.2-3 kVA: 8 IEC10A + 1 IEC16A   Rack kit included Interface LED LED EXB packs 4 1 kVA: 4 1.4-3 kVA: 10 Communication USB, RS232, contacts XL model: USB, RS232 XL Modular model: USB, RS232, SNMP

  18. Commercial catalogue • Evolution & Accessories:

  19. Switching examples New Evolution 650 tower Pulsar Evolution 500 Rack1U Tower • From 500 to 650 VA : • 2 kVA • 3 kVA Evolution 650 Rack 1U 400mm compatible Rack Tower or Short depth rack Evolution 2000 RT2U (2000VA/1600W) Evolution S 2500 RT2UNetpack (2500VA/2250W) Rack, Long Runtime Pulsar Evolution 2200 (2200VA/1540W) Evolution S 3000 RT3U (3000VA/2700W) Tower or Short depth rack Evolution S 3000 RT2UNetpack (3000VA/2700W) Rack-optimized Pulsar Evolution 3000 (3000VA/2000W)

  20. Key differences vs today • Evolution • New 650 Tower Model • New 2000 RT2U model (Pf= 0.8, RT format) • 50 VA added for Each Model • RPO-ROO feature • Contacts info as standard • No data line protection • Evolution S • more Watts (Pf=0.9) • EXB starting at 1250 VA (compared with 2200 for Pulsar Evolution) • compatible with HotSwap MBP and FlexPDU • 2 form factors available for the Evolution S 3000 (2U dense & 3U short) • RPO-ROO feature • Contacts info as standard • Netpack versions with NMC card provided • 3000 XL version no longer exists • No data line protection

  21. Support Mgt. Repair Service offering for Evolution Evolution Legal warranty 2 years with product standard exchange Commissioning No commissioning needed/standard nor offered Warranty extension Warranty + : 66812-66813-66814-66818 Contract Maintenance contracts for large installed base, U, P, S type standard exchange delivered by MGE Teleservice (to be confirmed with NMTC card) Managed by International Customer Care Center for countries included in the project scope Product standard exchange level UPS 01 “type” UPS 02 “type”