NERC Policies

NERC Policies. Introduction. What is NERC?. Northeast U.S. blackout of 1965 Electric Power Reliability Act of 1967 Ten regional councils Organizational objectives Define and measure reliability Influence and interpret legislation regarding the power industry

vidal
Download Presentation

NERC Policies

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NERC Policies Introduction

  2. What is NERC? • Northeast U.S. blackout of 1965 • Electric Power Reliability Act of 1967 • Ten regional councils • Organizational objectives • Define and measure reliability • Influence and interpret legislation regarding the power industry • Study interregional connections

  3. NERC Regions NPCC MAPP MAAC ECAR WSCC MAIN SPP SERC ERCOT FRCC

  4. NERC Organization • Board of Trustees • Engineering Committee • Operating Committee

  5. NERC Operating Committee Mission • To promote the reliability of the electricity supply for North America, • To establish Policies, • To monitor compliance, • To provide a forum for dealing with issues.

  6. NERC Standards Development Players • Standards Committee • Operating Committee • Engineering Committee • Subgroup • Due Process Appeals Committee • Technical Appeals Committee

  7. Standards Development Process 1. Request to revise or develop standard 2. Assignment to subgroup 3. Drafting phase and Internet announcement 4. Draft standard posted for comment 5. Subgroup deliberates on comments 6. Draft standard submitted to Standards Committee 7. Standards Committee votes on recommendation to Board 8. Appeals processes 9. Board approves 10. Standard implementation or further appeals

  8. Waivers to NERC Operating Policies • Instances when an entity cannot comply with a NERC Operating Policy • Requested from the Operating Committee • Waiver request must include an alternative plan • Temporary

  9. Waivers in Effect • Scheduling Agent • Alliance RTO • Midwest ISO • Southwest Power Pool • GridSouth • Financial Inadvertent Settlement • Alliance RTO • Midwest ISO • Southwest Power Pool • Control Performance Standard 2 • ERCOT

  10. Personnel Subcommittee • Responsible for support materials • Promotes sharing of knowledge • Periodically reviews NERC Operating Policies pertaining to System Operator training and certification and recommends revisions • Establishes policies and standards for NERC System Operator Certification • Serves as the interim governance body for the NERC System Operator Certification Program

  11. Introduction to the Operating Policies NERC Doctrine • Policies -- Place responsibility for operating reliability on the Control Areas • Standards -- Requirements that are measurable and may be audited with surveys • Requirements -- Describe the obligations of a Control Area • Guides -- Operating practices to be considered

  12. Interconnections

  13. Control Area • An electrical system bounded by interconnection (tie-line) metering and telemetry • Two requirements: • Directly controls its generation to balance its actual and scheduled interchange • Helps regulate and stabilize the Interconnection’s alternating-current frequency

  14. Control Area Obligations • Interchange balance • Interconnection frequency

  15. Interchange Balance

  16. Control Area B Control Area D 100 MW 150 MW Control Area A tie line flow = 100 -150 + 100 - 50 = 0 Control Area C Control Area E 50 MW 100 MW Generation & Load Balancing

  17. Interconnection Frequency • Automatic Generation Control (AGC) • Generator governors

  18. Compliance Control Areas are obligated to adhere to all NERC Operating Requirements and Standards.

  19. Control Area Reporting • Inadvertent Interchange Accounting • Control Performance Surveys • Area Interchange Error Surveys • Frequency Response Characteristic Surveys • Frequency Bias Settings • Allowable Limit of Average Deviation Survey

  20. Security Coordinators • Established in 1996 • Established the requirements for sharing of data and information about the “health” of the Interconnection • Established the Interregional Security Network for each Interconnection • Required every Region, subregion, or interregional coordinating group to establish a Security Coordinator • Required that each Region develop a security plan • Rely on common operating terminology, criteria and standards

  21. Operating Policy Layout

  22. NERC Operating Policy Terms • Several pages of terms and definitions are located in the Operating Manual

  23. Confirmation as a Control Area To be recognized as a NERC-Certified CONTROL AREA, the entity must be reviewed by the REGIONAL COUNCIL in which the entity is a member and and confirmed that it meets the requirements of the specified Criteria.

  24. Control Area Criteria • Generation • Metering • Communications • Transmission Arrangements • System Operators • E-tag Services • Performance Surveys • Back-up Control Center • Coordination • System Restoration • Compliance with NERC Operating Policies and Standards

  25. Security Coordinator Standards of Conduct

  26. Security Coordinator Standards of Conduct • Independent of employees/persons who engage in retail or wholesale merchant functions • Abide by rules governing employee conduct • Written procedures publicly available and provided to all Security Coordinator employees

  27. Questions?