1 / 87

PV-wirefree: Bringing PV systems back to their essentials

wirefree. PV. PV-wirefree: Bringing PV systems back to their essentials. Henk Oldenkamp OKE-Services, The Netherlands 12 May 2003 Web: www.pv-wirefree.com. 3 rd World Conference on Photovoltaic Energy Conversion, Osaka, Japan. Overview presentation . Why PV-wirefree? What is PV-wirefree?

Download Presentation

PV-wirefree: Bringing PV systems back to their essentials

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. wirefree PV PV-wirefree:Bringing PV systemsback to their essentials Henk OldenkampOKE-Services, The Netherlands12 May 2003Web: www.pv-wirefree.com 3rd World Conference on Photovoltaic Energy Conversion, Osaka, Japan

  2. Overview presentation • Why PV-wirefree? • What is PV-wirefree? • Design • Comparison of PV-wirefree and string systems • Status and developments • Conclusions

  3. PV-wirefree objectives • To minimize BOS-costs of PV-systems • PV-wirefree will reduce the PV BOS costs with 50% • To minimize costs electricity generated by PV-systems • PV-wirefree will decrease the kWh costs of PV with 25% • To minimize energy pay-back time and optimize LCA of PV-systems

  4. What is PV-wirefee? How to reach these objectives? Currently many components are used in grid-connected PV-systems. At the DC-side we find the following components:

  5. What is PV-wirefee? How to reach these objectives? In this presentation we will show that all these components can be omitted and/or replaced by the only four essential ones:

  6. What is PV-wirefee? – How to reach these objectives? Back to basics approach What are the essential components of a PV-system? • PV-laminates consisting of PV-cells to generate electricity • Conductor to carry the DC-current from the PV-laminate to an inverter • Inverter to convert DC- to AC-power

  7. What is PV-wirefee? – How to reach these objectives? Ultimate integration of functions

  8. What is PV-wirefee? – How to reach these objectives? The basics of PV-wirefree • Large numbers of PV-laminates connected in parallel using a current carrying mounting frame (= mounting bus) • Each group of PV-laminates connected to one set of mounting busses has its own inverter, and is called a subsystem

  9. Design Design method • To abolish so many components  clear design choices  affects and limits design freedom of the other components. • Leading design choice: optimizing the most expensive component = PV-laminate • Step 1: Optimize PV-laminate dimensions • Step 2: Design mounting bus • Step 3: Design module connector • Step 4: Design inverter

  10. Design Touch safety • In PV-wirefree systems bare conductors are used • International safety standards require: • In dry conditions: voltage < 60 V • In wet conditions: voltage < 30 V • PV-wirefree open circuit voltage will be 21 V

  11. Design Energy hazard • Power of PV-wirefree systems > 240 VA • International safety standards require following measures: • Sufficient separation of bare conductors • European requirements: test finger of about 8 cm shall not be able to make a short circuit • American requirements: tool shall not be able to make a short circuit • PV-wirefree uses spacing between mounting busses > 0.50 m

  12. PV-wirefree laminate Mounting bus Module connector Inverter Step 1 Design – Method – Overview Design step 1: laminate

  13. Design – Method – PV-wirefree laminate Basic assumptions PV-wirefree should be suitable for “nearly all” PV market sectors.  The PV-laminate should be designed for: • Flat and sloped roofs, facades and desert plants (VLS-PV) • Both multi and polycrystalline silicone cells • Cells of the following dimensions: 12,5 x 12,5; 15 x 15 and 20 x 20 cm.

  14. Design – Method – PV-wirefree laminate To meet our goals • Minimize material use and costs  replace frame by 4 points mechanical connection ( no pollution like moss-grow) • Minimize material use and costs  limit wiring to cell-to-cell wiring, omit junction box • Minimize labour costs  easy installation  click and fit system • Minimize costs  use standard 4 mm PV-glass (heat strengthened)

  15. Design – Method – PV-wirefree laminate To meet general standards For heat strengthened glass a.o. the following figures apply: • According to IEC 61215 laminates should resist a test wind load of 2400 Pa • Additional safety factors vary per country. Maximum calculated stress must be in the range of 50-80 N/mm² at the actual design wind load. • At most locations in Europe the maximum wind load is well below 1500 Pa • Actual breaking will occur at 200 – 300 N/mm² • Working conditions allow a maximum weight per PV module of about 10 kg

  16. Design – Method – PV-wirefree laminate Design choices The PV-wirefree laminate should: • Withstand a test wind load of 2400 Pa, while the stress of the glass should not exceed 80 N/mm². This implies 50 N/mm² at a wind load of 1500 Pa. • Use standard 4 mm heat strengthened glass (common for PV). For calculations 3,8 mm must be used to cope with tolerances of glass thickness • Have an area of maximal 1 m² (not to exceed weight of about 10 kg per PV-module)

  17. Design – Method – PV-wirefree laminate In search of the right dimensions • Currently: 4 x 9 cells

  18. Design – Method – PV-wirefree laminate Stress analysis: 4 x 9 cells laminate (1) Laminate: • 4 x 9 cells 150 mm • 0.649 m x 1.414 m = 0.981 m² Fixing: • Stiff in the corners Result: • Maximum stress in laminate: approximately 800 N/mm² (at a test wind load of 2400 Pa)

  19. Design – Method – PV-wirefree laminate Stress analysis: 4 x 9 cells laminate (2) Laminate: • 4 x 9 cells 150 mm • 0.649 m x 1.414 m = 0.981 m² Fixing: • Stiff at optimum position: distance between fixings 0.774 m Result: • Maximum stress in laminate: approximately 200 N/mm² (at a test wind load of 2400 Pa)

  20. Design – Method – PV-wirefree laminate Stress analysis: 4 x 9 cells laminate (3) Laminate: • 4 x 9 cells 150 mm • 0.649 m x 1.414 m = 0.981 m² Fixing: • Flexible at optimum position: distance between fixings 0.774 m Result: • Maximum stress in laminate: approximately 130 N/mm² (at at test wind load of 2400 Pa)

  21. Design – Method – PV-wirefree laminate Stress analysisConclusions 4 x 9 cells laminate • 4 points connection not feasible for standard 4 x 9 cells laminates (150 mm cells) since even for an optimized design maximum stress in glass is 130 N/mm² at a test wind load of 2400 Pa

  22. Design – Method – PV-wirefree laminate In search of the right dimensions • Let’s study a 5 x 7 cells module instead of a 4 x 9 cells module

  23. Design – Method – PV-wirefree laminate Stress analysis: 5 x 7 cells laminate (1) PV-wirefree laminate: • 5 x 7 cells 150 mm • 0.802 m x 1.108 m = 0.889 m² Fixing: • Fixed at optimum position: distance between fixings 0.648 m Result: • Maximum stress in laminate: approximately 160 N/mm² (at a test wind load of 2400 Pa)

  24. Design – Method – PV-wirefree laminate Stress analysis: 5 x 7 cells laminate (2) PV-wirefree laminate: • 5 x 7 cells 150 mm • 0.802 m x 1.108 m = 0.889 m² Fixing: • Flexible at optimum position: distance between fixings 0.648 m Result: • Maximum stress in laminate: approximately 100 N/mm² (at a test wind load of 2400 Pa)

  25. Design – Method – PV-wirefree laminate Stress analysis: 5 x 7 cells laminate (3) PV-wirefree laminate: • 5 x 7 cells 150 mm • 0.802 m x 1.108 m = 0.889 m² Fixing: • Flexible at optimum position: distance between fixings 0.648 m • Optimized connector Result: • Maximum stress in laminate: approximately 80 N/mm² (at a test wind load 2400 Pa)

  26. Design – Method – PV-wirefree laminate Stress analysisConclusions 5 x 7 cells laminate • 4 points connection feasible for PV-wirefree laminate of 5 x 7 cells (150 mm cells). • The maximum stress in glass is 80 N/mm² at a test wind load of 2400 Pa • Provided a properly engineered connector located at optimal bus distance

  27. Design – Method – PV-wirefree laminate In search of the right dimensions • Other possible dimensions: 5 x 7 cells (125 mm) and 4 x 5 cells (200 mm)

  28. Design – Method – PV-wirefree laminate Stress analysis: 4 x 5 cells laminate PV-wirefree laminate: • 4 x 5 cells 200 mm • 0.849 m x 1.052 m = 0.893 m² Fixing: • Flexible at optimum position: distance between fixings 0.612 m • Optimized connector Result: • Maximum stress in laminate: approximately 80 N/mm² (at a test wind load of 2400 Pa)

  29. Design – Method – PV-wirefree laminate Stress analysis: 5 x 7 cells laminate PV-wirefree laminate: • 5 x 7 cells 125 mm • 0.677 m x 0.933 m = 0.632 m² Fixing: • Flexible at optimum position: distance between fixings 0.533 m • Optimized connector Result: • Maximum stress in laminate: approximately 52 N/mm² (at a test wind load of 2400 Pa)

  30. Design – Method – PV-wirefree laminate - Dimensions Stress analysisoverall conclusions • 4 points connection feasible for PV-wirefree laminates of • 5 x 7 cells laminates (150 mm cells)  80 N/mm² • 4 x 5 cells laminates (200 mm cells)  80 N/mm² • 5 x 7 cells laminates (125 mm cells)  52 N/mm² at a test wind load of 2400 Pa Note: Provided a properly engineered connector located at optimal bus distance

  31. Design – Method – PV-wirefree laminate Cell interconnection= Additional advantage • 4 x 9 cells  5 x 7 cells • Wiring limited to cell to cell wiring • Increased safety

  32. Design – Method – PV-wirefree laminate Cell interconnection= Additional advantage • PV-wirefree laminate of 5 x 4 cells. • But wiring should be done properly

  33. Design – Method – PV-wirefree laminate Top 3 PV-wirefree laminates

  34. PV-wirefree laminate Mounting bus Module connector Inverter 5 x 7 cells (12,5 x 12,5 and 15 x 15 cm) and 4 x 5 cells (20 x 20 cm) 4 mm re-enforced glass 4 points connection (no frame) Optimum distance between mounting busses Step 2 Design – Method – Overview Design step 2: mounting bus

  35. Design – Method – PV-wirefree mounting bus Design choices The mounting bus should: • be strong enough to carry the weight of the PV-laminates and the wind load on the PV-laminates • have a cross area sufficient to carry the current of the subsystem of parallel connected PV-laminates • be made of material suitable to provide a reliable electrical contact • be able to be fixed easily to the roof • be rugged • be low cost

  36. Design – Method – PV-wirefree mounting bus Material selection

  37. Design – Method – PV-wirefree mounting bus Material selection Comparison design of a wire with a resistance of 0.001 Ohm/m

  38. Design – Method – PV-wirefree mounting bus Material selection: conclusions • Energy content per amount of conduction of aluminum is lower than steel and comparable with copper. • The costs per amount of conduction of aluminum is lower than steel and copper. • Since aluminum is used as common building material and can easily be extruded in virtually any shape  material choice = aluminum

  39. Design – Method – PV-wirefree mounting bus Dimensions • In order to withstand mechanical loads from the PV-modules – caused by the wind load on the PV-modules (2400 Pa) – and to be rugged enough A strength optimized profile of approx 150 mm² is required. • Based on this profile the maximum PV-wirefree subsystem size is approximately 3-4 kW for the 5 x 7 cells laminates and 1 kW for the 4 x 5 cells laminates • Aluminum used: 0.67 kg per module, resulting in a energy pay back time of 2 months (5 x 7 cells, 150 mm)

  40. PV-wirefree laminate Mounting bus Module connector Inverter 5 x 7 cells (12,5 x 12,5 and 15 x 15 cm) and 4 x 5 cells (20 x 20 cm) 4 mm re-enforced glass 4 points connection (no frame) Optimum distance between mounting busses Cross section of > 150 mm² Material aluminum Step 3 Design – Method – Overview Design step 3: module connector

  41. Design – Method – PV-wirefree module connector Design choices The PV-wirefree module connector should: • Provide mechanical support by a 4-points connection • Strong enough to withstand the wind loads at the PV-laminate • Electrically connect the PV-laminate to the mounting bus • Have a life time > 20 jaar • Provide a visually checking possibility for correct mating • Provide suitable means for unmating

  42. Design – Method – PV-wirefree module connector Material selection • Aluminum selected for the mounting bus • Avoid corrosion caused by the difference in electrochemical potential of different metals.  Aluminum-Aluminum contact: all electrically connected outdoor metals should be aluminum • Including contacts • Including terminals coming laminate • This also avoids costs of finishing.

  43. Design – Method – PV-wirefree module connector Al-Al contact principle A reliable outdoor contact between Al-Al requires: • Stabilized normal contact force of about 100 N to crush the thin aluminium-oxide layer, guaranteeing a reliable connection for > 20 years • After mating the contact surfaces shall not move

  44. Design – Method – PV-wirefree module connector Impressions module connector

  45. PV-wirefree laminate Mounting bus Module connector Inverter 5 x 7 cells (12,5 x 12,5 and 15 x 15 cm) and 4 x 5 cells (20 x 20 cm) 4 mm re-enforced glass 4 points connection (no frame) Optimum distance between mounting busses Cross section of > 150 mm² Material aluminum Aluminum – aluminum connection Stabilized normal force should be > 100 N Step 4 Design – Method – Overview Design step 4: inverter

  46. Design – Method – PV-wirefree inverter Design choices The PV-wirefree inverter should: • Have a working input voltage matching the PV-wirefree laminates of approx 15 V (35 cells laminate) or 8 V (20 cells laminate) • Not load the PV-modules below Vmpp for longer periods • Never short the PV-laminates even in single fault conditions, both inside and outside the inverter for longer periods • Have an efficiency comparable with existing inverters • Have redundant and rugged connections to the mounting bus • Have a price per watt comparable with existing inverters

  47. Design – Method – PV-wirefree inverter No short-circuit • To avoid an external short-circuit between the inputs of the inverter, these terminals should be properly separated. • Therefore only the enclosure is grounded and PV-modules are floating, so a short circuit is not possible at single fault conditions

  48. Design – Method – PV-wirefree inverter Latest results • Topology developed meeting these requirements. Even under multiple fault conditions – like mosfet, diode or driver failure – the inputs will not be short-circuited • Testing 350 W model has started • The topology has acceptable efficiency • Well scalable to the size required for PV-wirefree • First model will be approx 700 Wac.

  49. PV-wirefree laminate Mounting bus Module connector Inverter 5 x 7 cells (12,5 x 12,5 and 15 x 15 cm) and 4 x 5 cells (20 x 20 cm) 4 mm re-enforced glass 4 points connection (no frame) Optimum distance between mounting busses Cross section of > 150 mm² Material aluminum Aluminum – aluminum connection Stabilized normal force should be > 100 N Operating input voltage of 15 V (8 V) Efficiency > 92% (overall) Protecting from short circuits in system Ground fault detection Redundant connection to mounting bus Price: < 0.5 €/watt (large numbers) Design – Method – Overview Overview PV-wirefree components and their properties

  50. Intermezzo:Why we can omit so many components?