1 / 13

Kalman Fit For PHENIX Central Arms

Kalman Fit For PHENIX Central Arms. Evolution of Fit Formalism What is the Kalman Fit? New formalism for non-linear measurement matrix Results for Run-3 dAu Mass 2 resolution for p/pbar Simulation results for Run-4 configuration Improved momentum resolution at high p T Application to SVX

perry-sloan
Download Presentation

Kalman Fit For PHENIX Central Arms

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Kalman Fit For PHENIX Central Arms • Evolution of Fit Formalism • What is the Kalman Fit? • New formalism for non-linear measurement matrix • Results for Run-3 dAu • Mass2 resolution for p/pbar • Simulation results for Run-4 configuration • Improved momentum resolution at high pT • Application to SVX • Measurement of displaced vertices J. Lajoie - Kalman Fit for PHENIX

  2. The Kalman Filter • General Introduction • …goes here J. Lajoie - Kalman Fit for PHENIX

  3. What can we hope for? Very old MC study – assumed 150um TEC resolution and observed poor momentum for standard reconstruction. Not much Improvement below 5 GeV/c, ~x3 improvement at 20GeV/c. Just adding PC’s gives modest improvement (west arm). J. Lajoie - Kalman Fit for PHENIX

  4. Application to Run-3 dAu • Run 69502 • dAu chosen as a start to avoid hit association issues • On everybody’s “good run” list • Good TEC efficiency in sectors 2,3 (TOF) • Reconstructed and fit 190 file segments • Kalman uses DC X, UV hits, PC1, and TEC • UV hits fit only in z, filtered at 2.5 sigma • Magnetic field scaled up by 1.7% • Examine fit systematics… J. Lajoie - Kalman Fit for PHENIX

  5. Time to Run Kalman Filter J. Lajoie - Kalman Fit for PHENIX

  6. Chi-Square Distributions Not a true chi-square per d.o.f – just the total chi-square divided by the of contributing detector hits. J. Lajoie - Kalman Fit for PHENIX

  7. TEC “residuals” Look at TEC residuals for sectors 2,3 (TOF coverage) for “in” point (TEC “out” point is similar) Red: before Kalman Fit Blue: after Kalman Fit Number of tracks Number of tracks Dj (radians) Dj (radians) The track is “pulled” to the TEC hits by the fit. J. Lajoie - Kalman Fit for PHENIX

  8. Run 3 dAu – p/pbar mass2 Good DC tracks, with associated TOF, PC3 hits and TEC track. pT>2.0 GeV/c Kalman Fit (DC+PC1+TEC) Standard PHENIX Number of tracks Very small effect (if any), but at “low” pT. J. Lajoie - Kalman Fit for PHENIX

  9. Momentum Distribution Momentum distribution for all tracks with associated TEC track: Red: before Kalman Fit Blue: after Kalman Fit Number of tracks pT (GeV/c) Softer slope for distribution after Kalman fit, consistent with improved resolution. J. Lajoie - Kalman Fit for PHENIX

  10. Run-4 Simulation Results • Larger magnetic field (++ configuration) • More bend, better resolution • Kalman won’t help as much until higher pT • Single pion events in pisa • No decays, hadronic interactions • Examine ptot=2,5,10 and 20 GeV/c • East Arm: • Fit DC+PC1+TEC • West Arm • Fit DC+PC1+PC2+PC3 • Can Kalman help in Run-4? J. Lajoie - Kalman Fit for PHENIX

  11. Example: 20 GeV/c p+ (East Arm) Kalman CGL Almost a factor of two improvement in resolution! Number of tracks p (GeV/c) p (GeV/c) J. Lajoie - Kalman Fit for PHENIX

  12. Example: 20 GeV/c p+ (West Arm) Kalman CGL If anything the resolution got a little worse! Number of tracks p (GeV/c) p (GeV/c) J. Lajoie - Kalman Fit for PHENIX

  13. What’s going on in the West? • No resolution improvement with DC+PC1/2/3 • Resolution worsens a little (!) • Probably due to Kalman errors not tuned to MC • Assuming errors too small builds in fluctuations • Consistent with PC phi error being larger than “projection” error • Little information added from additional hits • No help for Run-4! J. Lajoie - Kalman Fit for PHENIX

More Related