1 / 19

Magnetic Shielding Studies of the LHCb RICH Photon Detectors

Magnetic Shielding Studies of the LHCb RICH Photon Detectors. Mitesh Patel, Marcello Losasso, Thierry Gys (CERN ). LHCb Experimental Goals. Large Samples of b decays at LHC N bb = 10 12 / year with Luminosity 2 × 10 32 cm -2 s -1 for p × 10 7 s

mcglynn
Download Presentation

Magnetic Shielding Studies of the LHCb RICH Photon Detectors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Magnetic Shielding Studies of the LHCb RICH Photon Detectors Mitesh Patel, Marcello Losasso, Thierry Gys (CERN)

  2. LHCb Experimental Goals • Large Samples of b decays at LHC • Nbb = 1012 / year with Luminosity 2×1032 cm-2s-1 for p×107s • b production predominately at small polar angle • Precision Measurements of CP Violation in b decays LHCb optimized as single forward arm spectrometer • Many pure hadronic final states Particle identification (/K) essential • Employ two RICH detectors • Use high efficiency photon detectors, sensitive to magnet fields • This talk calculation of the residual field seen by photon detectors Example Decays

  3. LHCb Experiment • Two RICH detectors either side of dipole magnet • Detectors experience stray field from the magnet • Stray field largest in upstream RICH detector (RICH1) – talk will focus on this upstream detector Muon System Z ~ 15.0-20.0 m RICH2 Z ~ 9.5-11.9 m CF4 RICH1 Z ~ 1.0-2.2 m • Aerogel and C4F10 Calorimeters Z ~ 12.5-15.0 m Dipole Magnet 4 Tm

  4. |B|/ G 1600 B.dl > 100 kGcm z/cm 0 0 250 Magnetic Requirements Must satisfy two conflicting requirements : • Deliver field between Vertex Locator and Trigger Tracker (charged particle momentum determination for efficient triggering) • Shield the RICH photon detectors from the field such that they operate efficiently LHCb Magnet The LHCb Magnet Hybrid PhotonDetector Magnetic shield developed that meets these requirements

  5. Primary Magnetic Shield Readout electronics Secondary shields/Photon detectors Beam pipe Spherical mirrors Flat mirrors Magnetic Shielding in RICH 1 • Primary Magnetic shield used to channel flux around the photon detector array • Shield made from high permeability iron : armco • Lab tests bare hybrid photon detectors (HPDs) operate efficiently up to ~15G • Simulations indicate residual field inside primary shield ~25G • Use set of secondary shields (one for each photon detector) to reduce this to acceptable level • Shields made from high permeability material, baseline solution: Mu-metal • Alternative possibility : supranhyster-36

  6. Magnetic Model • Now have a complicated magnetic environment : • Armco primary magnetic shield • Array of 14×7 individual secondary shields within this primary shield • Would like to check that, in this environment : • Magnetic flux does not short circuit through the detector array • Residual field inside shields acceptable (<10G) • Field in secondary shields not close to saturation (7kG) Finite element calculation

  7. 11m 4m 2.5m • Opera-3d software made by Vector Fields • First measurements (RICH2) show good agreement simulation/data • Model of Magnet and primary RICH1 shield uses up all elements software can cope with • Large volume – elements must extend into air far enough outside to encompass majority of field • Complicated conductor and shims • Wish to introduce into this model elements to form ~1mm thick secondary shields • ~1mm thick shields ~1m magnet

  8. Sub-modelling complete model • Take complete model with (relatively) coarse meshing in region of interest • Extract potential at nodes in region of interest • Apply this potential to nodes of a part(ial) model (boundary such that don’t expect potential to change with introduction of secondary shields) • The new part model is then solved separately (potential allowed to evolve except at boundary where fixed) • Part model then a much smaller volume • More elements available to model secondary shields primary shield magnet part model nodes

  9. Magnetic Potential : (complete model – part model) Magnetic Potential : complete model • Potential at boundary fixed perturbation from adding secondary shields inside the primary shield must not spread to edges • Even with sub-modelling still limited by no. of elements rectangular rather than circular cross-section secondary shields Without Mu-metal With Mu-metal

  10. 0.866P rather than 0.866P P P • Build array of 14×7 shields, 0.9 mm thick with staggered geometry • cf circular shields have 10% more material • If shields close to saturation, fact have : may become relevant • Put this array inside part model of primary shield : • Solve part model twice : • With secondary shield elements made from mu-metal • With the same elements but made from air

  11. Effect on Field at Detector Plane With mu-metal shields Without mu-metal shields 20G 0G X=0cm X=35cm X=0cm X=35cm • Field inside HPD volume falls from ~20G to <10G • Field even lower in set of shields closest to internal shelf…

  12. 20G With mu-metal shields Without mu-metal shields (White regions: field greater than 20G maximum) |B| / G 0G • Side view shows same difference in |B| in tubes closest to internal shelf Position / cm

  13. 20G With mu-metal shields Without mu-metal shields (White regions: field greater than 20G maximum) 0G • Field has transverse component in the tube closest to shelf – very well shielded • In all other tubes – field mostly longitudinal

  14. Field highest inside shields at the centre of the array • Peak field ~8G |B| / G Position / cm

  15. Field in the Mu-metal |B| / G Position / cm • Fields ≤2kG – well away from saturation (7kG) • Field highest at bottom of array, closest to internal shelf and the side walls of the shield • Peak field ~3.9kG |B| / G Position / cm

  16. Extending the Shield Protrusion 1cm - Field at HPD plane 20G With mu-metal shields With extended mu-metal shields |B| / G |B| / G 0G 0G Position / cm Position / cm Peak field at HPD plane : 8G Peak field at HPD plane : 6G • Essentially no change in flux channelled through Mu-metal

  17. Changing Shield Material from Mu-metal to Supranhyster-36 • Supranhyster-36 lower permeability material but expect similar shielding performance • Supranhyster-36 has higher saturation value : 11kG (cf mu-metal, saturation at 7kG) gives more margin • Model indicates that mu-metal is far from saturation so not critical • No discernable change in field seen at HPD photocathode plane • See similar peak field to that seen in the mu-metal With supranhyster-36 shields Position / cm

  18. Conclusions • Using an array of individual secondary shields around the photon detectors inside the primary RICH1 magnetic shield : • Field at photon detector photocathode plane falls from ~20G to <8G • B mostly longitudinal- apart from in set of shields closest to internal shelf • Field channelled through Mu-metal shields ≤2kG, peak field 3.9kG – half way from saturating • Extending mu-metal shields by 1cm 6G peak field instead of 8G • Changing the material of the secondary shields to supranhyster-36 • similar shielding efficiency/peak field in shields but saturation then at 11kG The magnetic environment in the (more sensitive) upstream RICH detector of LHCb is such that the photon detectors will operate efficiently A method of mapping the field in-situ and compensating for the effect of the residual field is being developed (see the talk of A. Van Lysebetten)

  19. Photon Detector : The LHCb Pixel HPD • Require : • Cover total area ~ 2.8 m2 • Single photon sensitivity • Granularity ~ 2.5mm x 2.5mm • Visible and near-UV sensitivity • 25ns time resolution Solution :The LHCb Pixel Hybrid Photon Detector Electron optics: Cross-focussed, demagnification ~ 5 Anode: 16×16mm2 Si pixel detector, bump-bonded to 40MHz binary readout chip Pixel cell: 62.5mm x 500mm: 256 x 32 matrix Effective pixel size at photocathode: 2.5mm x 2.5mm: 1024 channels