An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Biofeedback Chapter 7

  2. Biofeedback • Electronic or electromechanical instruments that accurately measures, processes, and provides feedback via auditory or visual signals • Used to help patient develop greater voluntary control of either • Neuromuscular relaxation, or • Muscle re-education following injury

  3. Role of Biofeedback • Intrinsic feedback = movement • Kinesthetic, visual, cutaneous, vestibular, and auditory signals • Extrinsic feedback = knowledge • Results presented verbally, mechanically, or electronically to indicate the outcome of some movement performance

  4. Role of Biofeedback • Feedback is ongoing • Occurs before, during, and after any motor or movement task • Feedback from some measuring instrument which provides moment-to-moment information about a biologic function is referred to as biofeedback

  5. Role of Biofeedback • Patient able to make appropriate, small changes in performance which are immediately noted and rewarded • Eventually larger changes, or improvements, in performance can be accomplished • Goal = train patient to perceive changes without the use of a biofeedback unit

  6. Biofeedback Instruments • Measure electromyographic activity (EMG)indicating amount of electrical activity during muscle contraction • Most common type of biofeedback used in athletic training

  7. EMG Biofeedback • Nerve fiber conducts an impulse to the neuromuscular junction where acetylcholine binds to receptor sites on the sarcolemma inducing a depolarization of the muscle fiber • Changes in electrochemical potential difference associated with depolarization can be detected by an electrode placed in close proximity

  8. Measuring Electrical Activity • EMG does not measure muscle contraction directly • Measures electrical activity associated with muscle contraction • Units of measure are microvolts • 1 volt = 1,000,000 µV • EMG readings may be compared only when the same equipment is used for all readings

  9. Measuring Electrical Activity • EMG biofeedback unit receives small amounts of electrical energy generated during muscle contraction (via the electrodes) • Separates or filters electrical energy from other extraneous electrical activity on skin • Amplifies the EMG electrical energy and converts it to some type of information which has meaning to the patient • Meter, auditory signal, light display

  10. Anatomy of EMG Biofeedback

  11. EMG Electrodes • Skin surface electrodes • Some electrodes permanently attach to cable wires while others may snap onto the wire • Some units include a set of three electrodes pre-placed on a velcro band which attaches to the skin

  12. EMG Electrodes • Size of electrodes varies • 4 mm diameter for small muscle activity • 12.5 mm diameter for larger muscles • Increasing the size of the electrode will not cause an increase in the amplitude of the signal • Electrodes may be disposable or non-disposable • Require some type of conducting gel

  13. EMG Electrode Placement • Prepare skin by scrubbing with an alcohol-soaked prep pad • Electrodes should be placed as near to the muscle being monitored as possible • Electrodes should be parallel to the direction of the muscle fibers • Spacing of the electrodes is critical to reduce extraneous electrical activity (noise)

  14. Separation and Amplification of EMG Activity • 2 active electrodes • 1 reference electrode • Active electrodes pick up electrical activity from motor units firing in the muscles beneath the electrodes

  15. Converting EMG Activity to Meaningful Information • Biofeedback units generally provide either visual or auditory feedback relative to the quantity of electrical activity • Visual feedback uses lights, bars, or analogue or digital meters • Auditory feedback uses increasing or decreasing tones, buzzing, beeping or clicking

  16. Setting Sensitivity • Sensitivity may be set at… • 1 µV, 10 µV, or 100 µV • A high sensitivity means the biofeedback unit is sensitive enough to detect the smallest amounts of electrical activity • Higher sensitivity levels should be used during relaxation training • Lower sensitivity levels should be used during muscle re-education training

  17. Clinical Applications • Muscle re-education • Isometric contractions sustained for 6-10 sec • Maximize feedback • Tx time = 5-10 min • Relaxation of muscle guarding/Pain control • Concentrate on muscle relaxation • Minimize feedback • Change positions

  18. Indications: • Muscle re-education • Regaining neuromuscular control • Increasing isometric/isotonic strength • Relaxation of muscle spasm/guarding • Pain reduction • Psychological relaxation Contraindications: • Any musculoskeletal condition in which a muscle contraction may exacerbate the condition