An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. External Tank Moisture Control Area(s) of Significant Benefit Safety Performance Sustainability Operations Infrastructure • Description • Develop a heating process to control moisture trapped within and behind the External Tank (ET) insulation. • Test the effectiveness of using heat to control moisture buildup at the insulation • Develop necessary Ground Support Equipment (GSE) to implement the selected procedure • Work with the ET manufacturer and designers to qualify this procedure. • Technologies and Capabilities • Heating is a common technique to prevent moisture buildup within cavities • The temperatures associated with this technique are a few degrees above the dew point and do not create a safety concern • Some concepts have no weight penalties Benefits and Impacts Obsolescence Reduction Risk Reduction Safety Improvement Cost Reduction Process Improvement Other (Ultra-High Operations Improvement Reliability) Performance Enhancement • POC, Cost, Schedule and Maturity • TRL 5 ET Moisture Control: 004 • Heating is a mature process for removing moisture • POC: W. G. Harris (321) 861-8942 • Minimizes the ET insulation/moisture concerns without scrapping expensive flight hardware • May have minimal weight penalty • Reduction in Criticality 1 Failure Rate of .01%

  2. External Tank Moisture Control • Total Project Costs: $ 3.4 M • Obsolescence & Feasibility: $ 0.5 M • Formulation: $ 0.9 M • Implementation: $ 2.0 M • Project Submitted By: W. G. Harris, (321) 861-8942 • Note: Supplemental Information attached in MS Word document