An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ESS CDS-EL and CDS-LTS2Project risks J. Polinski ESS CDS-EL and CDS-LTS2 TRR1 Meeting, 28 June 2017, Kriosystem, Wroclaw, Poland

  2. Control valves vs. Pressure Transducers • Due to first Control Valves tender failure, the Control Valves for the first VBoxes can be expected by the end of the Sept. 2017 • This generate the delay in the CDS-EL production and installation • In order to reduce the delay it is consider to order the Control Valves for first 2 Valve Boxes at Kriosystem • This can reduce the delay by 3-4 weeks

  3. Control valves vs. Pressure Transducers • WUST can place the additional order to Kriosystems up to 10% of the contract value or up to 209 kEuro gross without any additional procurement procedure. • The offer value for 2 sets of the Control Valves is 138 kEuro brutto

  4. Control valves vs. Pressure Transducers • There is also issue of the Pressure Transducers (PT) procurement: • The Honeywell PT, as a „standard” product, has no radiation resistance certification • If the radiation resistance requirement will be in the WUST tender specification, probably only very expensive, Emerson PT will be offered • If there is no the radiation resistance requirement will be in tender specification, many „standard” product can be offered. • Then „the cheapest” product must be selected

  5. Control valves vs. Pressure Transducers • The idea is to procure the Honeywell PTs via the Kriosystem. • The cost of PTs is of 100 kEuro gross • If we would like to procure the Control Valves for 2 VBoxes and PTs via Kriosystem it is necessary to increase the contract value by 240 kEuro gross against 209kEuro available