1 / 13

Transformer Gas Tester

Transformer Gas Tester. Agenda . Application Historical Solutions RKI ’ s Solution Features & Benefits Marketing. What is a Transformer?. Why Gas Testing?. Transformer head space is inerted (made oxygen-free) using nitrogen

jmartone
Download Presentation

Transformer Gas Tester

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transformer Gas Tester www.rkiinstruments.com

  2. Agenda • Application • Historical Solutions • RKI’s Solution • Features & Benefits • Marketing

  3. What is a Transformer?

  4. Why Gas Testing? • Transformer head space is inerted (made oxygen-free) using nitrogen • Internal failures cause electrical arcing between coils which causes the transformer oil to break down and produce flammable gases into the headspace (H2 typical) • The Eagle can be used to detect these gases as an early indication of problems

  5. Features and Benefits • Detects Hydrogen in % LEL / % Vol / ppm • Built-in dual pump dilution sampling system • Durable long life catalytic bead sensor • Sample positive or negative pressure transformers • No need for sample bags or external dilution fitting • Calibration automatically compensates for dilution of sample • Accurately detects flammable gases in inert atmosphere

  6. Features and Benefits • Audible and visual alarms • Powerful pump can draw from transformers with negative internal pressure • Able to operate from standard D size alkaline or Ni-Cad batteries • 30 hours operation on alkaline batteries • 18 hours operation on Ni-Cads

  7. Eagle Unique Features • The dual pump design is a reliable trouble-free method to provide the necessary dilution of the sample with ambient air • This method (as opposed to traditional dilution fitting) is not sensitive to hose length, filter condition, or transformer internal pressures • Dilution is automatically compensated for in calibration, no need to multiply or calculate readings

  8. Instrument Overview

  9. Eagle Transformer Flow Path

  10. Marketing • Web site: www.transformergastester.com • PDF deliverable summary • You Tube Video (product use & description) • Trade shows

  11. Marketing – Web Site

  12. Marketing – Deliverables Application Brief Data Sheet

  13. Questions?