Presented by. U.S.A. Tel. 01 586-779-8260 Fax 01 586-779-7704 Email trisco@comcast.net. Formaldehyde Neutralization in the Embalming Laboratory. W.E. Burkel , D.A. Mueller, and T.R. Gest Division of Anatomical Sciences University of Michigan Medical School.

Download Presentation

Presented by

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Presented by U.S.A. Tel. 01 586-779-8260 Fax 01 586-779-7704 Email trisco@comcast.net

  2. Formaldehyde Neutralization in the Embalming Laboratory W.E. Burkel , D.A. Mueller, and T.R. Gest Division of Anatomical Sciences University of Michigan Medical School

  3. TO: William Burkel, Professor Anatomy and Cell Biology • 5713 Medical Science Building II 0616 • FROM: Ed Valentine, Industrial Hygienist • DATE: September 29, 1994 • SUBJECT: Formaldebyde Sampling, Gross Anatomy Laboratory, Medical Science Building II • On September 16, 1994, samples of airborne formaldehyde were collected during a gross anatomy laboratory session in rooms 3635, 3637, 3613, and 3605 of the Medical Science Building II. During sampling, students and instructors dissected the neck region of cadavers fixed with an embalming solution containing formaldehyde, glutaraldehyde, and ethanol. • Samples were collected on Assay Technology passive dosimeters and were analyzed at an American Industrial Hygiene Association accredited laboratory. All samples were collected in the breathing zone of instructors and students. Four samples were collected for the duration of the lab session and five samples were collected during selected fifteen minute periods throughout the lab session...

  4. Federal and state standards for formaldehyde set perrnissible exposure limits at 0.75 ppm for an eight hour time‑weighted average exposure (TWA) and 2 ppm for a fifteen minute short term exposure limit (STEL). The results given in table one indicate that employees have been exposed above these limits. TWA results ranged from 0.29 to 1.15 ppm. The STEL results ranged from 1.2 to 4.1 ppm. The eight hour TWAs were calculated with the assumption that employees were not exposed to formaldehyde outside of the saunpled period. Engineering and/or administrative controls must be put into place to reduce formaldehyde exposure in the gross anatomy classes. The attached summary of the formaldehyde standard outlines the procedures that must be put into place at various exposure levels. The ventilation system must be checked for proper operation. If the system is operating correctly, and other means of exposure reduction cannot be implemented, modification of the ventilation system should be investigated through Facilities Planning and Design....

  5. TWA Before Engineering Controls--ppm TWA=breathing zone 1.15 0.72 0.35 exposure averaged 0.94 0.07 0.53 over 8 hours 0.48 0.43 1.80 0.29 0.63 0.63 Permissible limit 0.44 0.30 0.49 0.75 ppm 0.21 0.79 Average 0.60 STDEV 0.41 Range 0.21-1.80

  6. TWA - AFTER Engineering Controls - ppm TWA=breathing zone 0.37 0.49 0.32 exposure averaged 0.37 0.68 0.19 over 8 hours 0.29 0.35 0.14 0.32 0.40 0.11 Permissible limit 0.45 0.30 0.54 0.75 ppm 0.23 0.38 Average 0.35 STDEV 0.14 Range 0.11-0.68

  7. STEL Before Engineering Controls • STEL= Short term (15 min.) 2.70 1.60 1.50 • Exposure in breathing zone 1.90 1.30 1.60 • 4.10 1.801.30 Permissible STEL = 2.0 ppm 1.20 1.30 6.50 • 3.10 3.00 2.10 • 1.60 1.30 3.00 • Average 2.07 • STDEV 1.08 • Range 1.2-6.5

  8. STEL AFTER Engineering Controls • STEL= Short term (15 min.) 2.30 0.97 0.90 • Exposure in breathing zone 0.45 2.60 0.60 • 1.08 2.100.50 Permissible STEL = 2.0 ppm 3.00 1.20 3.40 • 1.30 0.40 • Average 1.63 • STDEV 1.02 • Range 0.45-3.4

  9. TIME WEIGHTED ANALYSIS TWA BEFORE AFTER AFTER AFTER ENGINEERING ENGINEERING INFUTRACE MEA CONTROLS CONTROLS

  10. SHORT TERM EXPOSTURE LIMIT BEFORE AFTER AFTER AFTER ENGINEERING ENGINEERING INFUTRACE MEA CONTROLS CONTROLS

  11. Date: Thu, 11 Dec 97 11:38:52 EST From: Janet Follo <follo@umich.edu> To: wburkel@umich.edu Subject: Formaldehyde Test Results Dr. Burkel Great News! I finally received the last of the formaldehyde results for the monitoring we did back in November with monoethanolamine. All results came back with non-detectable levels of formaldehyde. ....

  12. TO: William Burkel, Ph.D., Professor of Anatomy Horace Bomar, Director of Medical Facilities FROM: Janet Follo, OSEH Representative DATE: September 15, 1999 SUBJECT: Formaldehyde Exposure, Gross Anatomy Lab MS II On August 23, 1999 OSEH conducted air sampling for formaldehyde during a gross anatomy laboratory session in rooms 3605, 3613, 3635, and 3637 of the Medical Science Building II Sampling Results The results of this sampling survey indicated that TWA ranged from 0.09 ppm to 0.22 ppm, all below the PEL. The STEL results ranged from 0.30 ppm to 0.81 ppm, all below the STEL. Conclusions and Follow up The measured formaldehyde exposures for this survey are considered safe, in comparison to current criteria. The University has met the safety criteria of the Formaldehyde Standard and is currently exempt from major parts of the regulation. This includes air monitoring and medical surveillance requirements. Additional monitoring and or medical surveillance may be warranted if changes in the preparation of cadavers occur.

  13. Embalming: • Place Cadaver on embalming blocks to allow drainage • Disinfect body, shave hair • Identify cadaver in more than one location

  14. Place Cadaver on embalming blocks to allow drainage

  15. Disinfect Cadaver with Tris Spray

  16. Identify cadaver in Two or more Spots

  17. Identify Cadaver in more than one Location

  18. Embalming • Simple Instruments - • Aneurism Hooks, Large Bent Forceps, Scissors, Injection canula

  19. Embalming (continued): • Raise right common carotid and place injection canula • Raise right jugular vein and place long bent forceps into right atrium • Mix embalming chemical

  20. Raise Right Common Carotid and place injection canula • Raise Right Jugular Vein and place long bent forceps into right atrium and right ventricle

  21. Stock Embalming Chemical Formaldehyde (37%) 2.50 % Ethanol 13.53 % Non-Ionic Detergent 0.12 % EDTA 0.4 % Ethylene Glycol 3.38 % Gluteraldehyde 1.08 % Methanol 0.47 %

  22. Embalming Solution: Embalming Chemical - 23% Deionized Water - 77%

  23. First Injection • Inject Embalming Chemical at 20 pounds of pressure • Inject a 3.5 gallon solution • Wait 24 hours

  24. Second Injection • Same solution as first injection • Wait 24 hours

  25. Third Injection • Same solution as second injection except • Wait 48 hours

  26. Neutralization Injection • 10 quarts deionized water • Add 16 oz. of Trisco Formaldehyde Neutralizer • Inject chemical at 20 pounds pressure • Wait 24 hours • Remove instruments • Mist Cadaver with Tris Spray • Place in 5 mil plastic bag and seal shut

  27. Cost of Neutralization Trisco Formaldehyde Neutralizer - $2.25 per cadaver Infutrace - approximately $12.00 per cadaver

  28. Benefits of • Trisco Formaldehyde Neutralizer • No Formaldehyde exposure • No downdraft tables and equipment needed • No crystals • Low cost • Simple solution to formaldehyde problems • OSEH will love you

  29. Actual specimens embalmed and neutralized using the procedures described in this program

  30. Actual specimens embalmed and neutralized using the procedures described in this program

  31. Actual specimens embalmed and neutralized using the procedures described in this program

  32. Presented by U.S.A. Tel. 01 586-779-8260 Fax 01 586-779-7704 Email trisco@comcast.net