Ssd seu candidates investigation
This presentation is the property of its rightful owner.
Sponsored Links
1 / 26

SSD SEU Candidates Investigation PowerPoint PPT Presentation


  • 34 Views
  • Uploaded on
  • Presentation posted in: General

SSD SEU Candidates Investigation. All Candidates 2010 - 2013. Measured and Integrated Dose. RAMSES Sensors , but dose given in Sv and not in Rad

Download Presentation

SSD SEU Candidates Investigation

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Ssd seu candidates investigation

SSD SEU CandidatesInvestigation


All candidates 2010 2013

AllCandidates 2010 - 2013


Measured and integrated dose

Measured and Integrated Dose

  • RAMSES Sensors, but dose given in Sv and not in Rad

  • No sensorsexatlynearourracks (seenext slide map). The twonearest (on A side) are one on the miniframe (PMIL2513) and one at the edgeof the ALICE Cavern (PMIL2511). Ourracks are in between. Notsureifthere are sensors on I side

  • Twovaluesofmeasured and integrated dose, one per sensor


Measured dose 2010 2013 sv h pmil2513

Measured Dose 2010-2013 (Sv/h) – PMIL2513


Measured dose 2010 2013 sv h pmil2511

Measured Dose 2010-2013 (Sv/h) – PMIL2511


Measured dose 2010 2013 sv h pmil2513 zoom

Measured Dose 2010-2013 (Sv/h) – PMIL2513(Zoom)


Measured dose 2010 2013 sv h pmil2511 zoom

Measured Dose 2010-2013 (Sv/h) – PMIL2511(Zoom)


Integrated dose 2010 2013 sv pmil2513

Integrated Dose 2010-2013 (Sv) – PMIL2513


Integrated dose 2010 2013 sv pmil2511

Integrated Dose 2010-2013 (Sv) – PMIL2511


Ddl 513 event 1

DDL 513 – Event 1


Ddl 513 event 2

DDL 513 – Event 2


Ddl 513 event 3

DDL 513 – Event 3


Ddl 514 event 1

DDL 514 – Event 1


Ddl 514 event 2

DDL 514 – Event 2


Ddl 514 event 3

DDL 514 – Event 3


Ddl 516 event 1

DDL 516 – Event 1


Ddl 519 event 1

DDL 519 – Event 1


Ddl 521 event 1

DDL 521 – Event 1

The Log entry waswritten at 2.52 am (12/07/2010), butaccordingto the logbook the problemsstarted at leastaround 1 am.


Ddl 523 event 1

DDL 523 – Event 1


Dose absorbed when the seu happened pmil2513 pm2511

Dose absorbedwhen the SEU happened(PMIL2513 – PM2511)

  • DDL 521: 0.0076 Sv – 0.00055 Sv (this DDL is on I side butthisvalueismeasured on the A side. Notsureifthereis a RAMSES on I side)

  • DDL 514:

    • 1 event: 0.474 Sv – 0.0079 Sv (Probablysolved just with a powercycle)

    • 2 event: 0.606 Sv – 0.0082 Sv (ie 0.132 Sv – 0.0003 Sv wrtevent 1)

    • 3 event: 1.998 Sv – 0.0115 Sv (ie 1.396 Sv – 0.0033 Sv wrtevent 2)

  • DDL 513:

    • 1 event: 1.357 Sv – 0.0108 Sv

    • 2 event: 2.356 Sv – 0.0117 Sv (ie 1.000 Sv – 0.0009 Sv wrtevent 1)

    • 3 event: 3.004 Sv – 0.0124 Sv (ie 0.648 Sv – 0.0007 Sv wrtevent 2)

  • DDL 516: 2,797 Sv – 0.0123 Sv

  • DDL 519: 2.855 Sv – 0.0123 Sv

  • DDL 523: 2.982 Sv – 0.0124 Sv (this DDL is on I side butthisvalueismeasured on the A side. Notsureifthereis a RAMSES on I side)


Total instantaneous luminosity

Total InstantaneousLuminosity


Total instantaneous luminosity zoom

Total InstantaneousLuminosity (Zoom)


Total integrated luminosity

Total IntegratedLuminosity


Integrated dose integrated luminosity

Integrated Dose / IntegratedLuminosity


Conclusions

Conclusions

  • Some casesclearlyassociatedto a peak in the radiationmeasuredappeared just before the event:

    • DDL 513 event 1, DDL 514 events 2 and 3

  • Almostall the othershappenedduring STABLE BEAMS but no evidentpeak in the measured dose wrtimmediatelybefore or after.

  • Whichactionhastobetaken?


  • Login