STAND TEST 3MeV. POWER CONVERTERS AB-PO-PH ( Pulsed and High voltage converters) WHERE ARE WE ?. AB-PO-PH mars 2007. Jean-Pierre ROYER. STAND TEST 3MeV. Power converters summary. SOURCE H- 1 High Voltage Converter (40kV, 15 mA, dc) 1 High Voltage Converter (65kV, 4 mA, dc)

Download Presentation

STAND TEST 3MeV

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Stand test 3mev

STAND TEST 3MeV

POWER CONVERTERS

AB-PO-PH ( Pulsed and High voltage converters)

WHERE ARE WE ?

AB-PO-PH mars 2007

Jean-Pierre ROYER


Stand test 3mev

STAND TEST 3MeV

Power converters summary

SOURCE H-

  • 1 High Voltage Converter (40kV, 15 mA, dc)

  • 1 High Voltage Converter (65kV, 4 mA, dc)

  • PLCs for converters 40 and 65 kV

  • 1 Screen bias Converter 2 kV, 1A, dc

  • 1 Grid bias Converter 500V, 500mA dc

  • 1 Anode bias Converter (5 kV to 20 kV, 20A pulsed 2msec, I dc 20 mA)

    LEBT (SOURCE H-)

  • 2 pulsed solenoids converters (1200A, 800 microsec. , 2 Hz)

  • 4 « LPSS » for steerer (70V, 10A bipolar, dc)

  • 1 « LPS2 » for bending (50A, 35V, dc)

    CHOPPER LINE

  • 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)

  • 2  « LPSS » for steerer (35V, 20A, dc)

    KLYSTRON MODULATEUR

  • Prototype AB-PO (100kV, 20A, 800 microsec, 2Hz)

  • Indian collaboration (100kV, 20A, 800 microsec, 2Hz)

AB-PO-PH – mars 2007

J.P. Royer AB-PO-PH


Stand test 3mev

STAND TEST 3MeV

  • SOURCE H-

  • 1 High Voltage Converter (40kV, 10 mA, dc)

  • 1 High Voltage Converter (65kV, 2 mA, dc)

  • Technical Specification For DC High Voltage Power Converters Rated - 40 kV, 10 mA- 65 kV, 2 mA

  • AB-POEDMS No.: 799586

  • DO FUG, HEINZINGER, TECHNIX

  •  order: TECHNIX 22 kFS ( 40kV 15mA + 65 kV 4 mA)

  • delivery time ~ April 2007

  • PLC’s for converters 40 and 65 kV

  • AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • SOURCE H-

  • 1 Screen bias Converter 2 kV, 1A, dc

  •  order FUG 6384 Euros (similar LEIR) may 2007

  • 1 Grid bias Converter 500V, 200mA dc

  •  order FUG 3258 Euros (similar LEIR) may 2007

  • 1 Anode bias Converter (5 kV to 20 kV, 20A pulsed 2msec, I dc 20 mA)

  •  order capacitor 46 microf. 26 kV: delivery 11-6-2007

  •  specification for “capacitors charging power converter” doneand sent for DO (demand offer)

  • FUG, Heinzinger, Technix: answer foreseen end of march,

  • then order and manufacturing, cabling the cabinet at CERN with the different elements.

  • AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • LEBT (SOURCE H-)

  • 2 pulsed solenoid converters (1200A, 800 microsec. , 2 Hz)

  • 2 power converters modified (ex septa EPA-PS) :

    -No matching transformer

    -Third harmonic to be modified and adjusted

    -Active filter must work for 800 microseconds

    -Modifications and adjustments on regulation loops and electronics.

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • CHOPPER LINE

  • 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)

  • Market survey and call for tender for consolidation Linac 2 and Stand Test 3 MeV :

     Contract placed at OCEM. Delivery of 11 units foreseen for end May 2007

     12 kFS / power converter (power and electronics)

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • CHOPPER LINE

  • 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)

  • AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    Example of current and voltage waveforms delivered by a maxidiscap on a LEIR magnet

    voltage

    The flat top will be increase until 800 microsec.

    current

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

     Maxidiscap E1 to E4 

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • LEBT (SOURCE H-)

  • 4 « LPSS » for steerer (10A bipolar, dc)

  • 1 « LPS2 » for bending (50A, 35V, dc)

    • CHOPPER LINE

  • 2  « LPSS » for steerer (20A, dc)

  •  Power part: Delta power converters ordered and at CERN

  • Electronic crates and different electronics cards are in progress for manufacturing.

  • AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

     LPSS LPS2 E5 to E6 

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • KLYSTRON MODULATOR

  • 1-Indian collaboration (100kV, 20A, 800 microsec, 2Hz)

  • 2-Prototype AB-PO (100kV, 20A, 800 microsec, 2Hz)

  • It was foreseen to start the stand test 3MeV with the Indian modulator but now, due to the delay, the PO prototype will be installed for operation.

  • AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • MODULATOR PROTOTYPE

  • The most important parts have been ordered ( ex: capacitors, high voltage pulse transformer, power converters for charging capacitors and for filament heater, H.V. switch, etc…).

  • Mechanical assembling has begun.

  • Preliminary tests of components in lab are in progress.

  • Planning: first tests with klystron foreseen 15-9-2007

  • AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Pulsed power converter for klystron

    STAND TEST 3MeV

    Pulsed power converter for Klystron

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    Power converters AB-PO

    AB-PO-PH mars 2007

    J.P. Royer AB-PO-PH


    Stand test 3mev

    STAND TEST 3MeV

    • CONCLUSION for the different power converters:

    • Team PO/PH responsibility for 27 power converters ( High Voltage, pulsed or DC)

    • The planning is well followed to respect the general planning STAND TEST 3MeV.

    • Effort will be necessary to integrate, to test and to commissioning equipments

    • Permanent effort (mechanical design, manufacturing) for the high voltage pulsed power converter for klystron modulator.

    • Sometimes conflicts with other business: work for shut down, hardware test for start–up accelerators etc…