MFW Pump Discharge Check Valve OE Follow Up. Dominion North Anna Power Station. Gary W. Liffick FW System Engineer FSRUG, Feb 21-24, 2011. Outline. North Anna Power Station: MFW Pump Discharge Check Valve. Application Overview Background of OE31369 (update of OE29594)

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' MFW Pump Discharge Check Valve OE Follow Up' - akio


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
mfw pump discharge check valve oe follow up

MFW Pump Discharge Check ValveOE Follow Up

Dominion

North Anna Power Station

Gary W. Liffick

FW System Engineer

FSRUG,

Feb 21-24, 2011

outline
Outline

North Anna Power Station: MFW Pump Discharge Check Valve

  • Application Overview
  • Background of OE31369 (update of OE29594)
  • Corrective Action
  • Current Status
application overview
Application Overview

North Anna Power Station: MFW Pump Discharge Check Valve

  • PWR, 963 MWe, Westinghouse NSSS Operational Since:
    • June 1978 Unit 1
    • Dec 1980 Unit 2
  • Application is Main Feedwater Pump Discharge
    • 3 Pump Circuit, 2 Active, 1 Standby
  • NozzleCheck Replaced the Tilting Disk Check
    • October 2007 at 1-FW-19
  • Feedwater Normal Conditions:
    • 390 F, 1,180 psi, 15,000 GPM per Feedwater Pump
  • Enertech Supplied:
    • type DRV-B,18”-900#, RF Flanges, Commercial Grade
application overview1
Application Overview

North Anna Power Station: MFW Pump Discharge Check Valve

Enertech Supplied Type DRV-B:

  • 18”-900#
  • RF Flanges
  • Commercial Grade
  • WC6 body
  • ASTM A351 CF8M Diffuser and Disk
  • Inconel X-750 Spring
oe31369 mfw pump discharge check valve failed to fully close original oe29594
OE31369, MFW Pump Discharge check valve failed to fully close. Original OE29594.

North Anna Power Station: MFW Pump Discharge Check Valve

  • During March 2009 Outage, backflow detected through check valve.
  • Disassembly showed 1 broken spring and 2 with visible wear of spring coils due to friction.
  • Remaining Components indicate normal wear.
  • Factory installed new springs, radial guide assembly, performed seat leak test.
  • Returned to site as spare
corrective action
Corrective Action

North Anna Power Station: MFW Pump Discharge Check Valve

  • Increased clearance of spring holder and spring cavity.
  • Eliminate possible solid height of spring
  • No change to spring design
  • Improve check valve reliability without changing Vmin or disk closure force with zero flow
nozzlecheck valve type drv b 18 900 rf
NozzleCheck Valve, Type DRV-B 18”-900# RF

North Anna Power Station: MFW Pump Discharge Check Valve

drv b cutaway
DRV-B Cutaway

North Anna Power Station: MFW Pump Discharge Check Valve

nozzlecheck valve animation type drv b 18 900 rf
NozzleCheck Valve, Animation, Type DRV-B 18”-900# RF

North Anna Power Station: MFW Pump Discharge Check Valve

spring holder and spring
Spring Holder and Spring

North Anna Power Station: MFW Pump Discharge Check Valve

spring holder and spring1
Spring Holder and Spring

North Anna Power Station: MFW Pump Discharge Check Valve

Spring coil wear

Spring holder wear

spring holder and spring2
Spring Holder and Spring

North Anna Power Station: MFW Pump Discharge Check Valve

Spring coil wear

current status
Current Status

North Anna Power Station: MFW Pump Discharge Check Valve

  • Valves incorporating design changes were installed in all six check valve locations (3 per unit) during 2010
  • Two valves removed for modification & refurbishment Sept. 2010
  • Factory evaluation shows spring wear after 12 months and 18 months of service
  • Valves with the modification are operating per design
status as of jan 2011
Status as of Jan 2011

North Anna Power Station: MFW Pump Discharge Check Valve

Conclusion

  • Final conclusion is pending the removal of the check valves from service to confirm spring wear has been eliminated
  • Current PM frequency is 4.5 years
  • Next valve scheduled for removal/PM is during Spring 2012
questions
Questions?

North Anna Power Station: MFW Pump Discharge Check Valve

Gary W. Liffick, FW System Engineer