1 / 42

FROM ONE CHROMATOGRAPH ...

FROM ONE CHROMATOGRAPH . … TO INDUSTRIAL LABORATORY. The UniChrom-97™ Data System is a complex of hardware and software components intended to UPGRADE existing or CREATE A NEW analytical devices park no matter at RESEARCH or INDUSTRIAL laboratory. .

Leo
Download Presentation

FROM ONE CHROMATOGRAPH ...

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FROM ONE CHROMATOGRAPH ... … TO INDUSTRIAL LABORATORY

  2. The UniChrom-97™ Data Systemis a complex of hardware and software components intended to UPGRADE existing or CREATE A NEWanalytical devices park no matter at RESEARCH or INDUSTRIAL laboratory.

  3. The UniChrom Data System supports connection up to 16 chromatographs simultaneously to ONE computer. And so on ...

  4. Our product is intended to automate chromatographic analysis, analytical methods development and to carry out routine and research analysis of any kind of complexity.

  5. UniChrom™ can work on computers from 386DX40 under 32-bit Microsoft® operating systems Windows 95™ Windows 98™ Windows NT 4.0™ Windows 2000™ Yes! and requires about 4 Megabytes  on hard disk.Your storage - for Your Data !

  6. Main Highlights: ADC LNet - Connection directly to chromatograph detector. There is no need in low current amplifiers - that is all in one - Lnet = ADC + Amplifier. STATE METROLOGY CERTIFICATE

  7. Unique connection possibility to any type of chromatograph. Achieved due to built-in low voltage and low-current amplifier into ADC Lnet. Typical noise levels2·10-14 A and 0.3 mkV respectively. No analogues!

  8. Unique connection possibility to any type of chromatograph. Automated gain switching under microprocessor control allows registration of compounds concentration in range from 0.00001% to 100%without manual intervention. No analogues!

  9. Unique drivers collection. Installation simplicity. JUST DRAG’N’DROP DRIVER YOU NEED WITH A MoUSE 

  10. Supports dozen of analytical instruments for GAS and LIQUID chromatography

  11. HP-5890andHP-4890 Our support for popular gas chromatographs from Agilent / Hewlett Packard® Corp.HP-5890 (A, Series II) and HP-4890D. Signal registration from both channels over digital path, total temperature programme and zones state control.

  12. HP-6890 andHP-6850instruments of 21 century Our full support for new chromatographs fromAgilent / Hewlett Packard® Corp.HP-6890, 6890 Plus, 6890N and HP-6850. Signal registration from both (6890) channels over digital path, total temperature programme and zone states control.

  13. Crystall-2000MRussian gas chromatographof 21 century Our full support of Russian gas chromatograph made by SDB «Chromatec» Crystall-2000M Signal registration from 4 channels using digital interface, total temperature programme and zone states control

  14. Crystall-5000Russian gas chromatographof 21 century Our full support of NEW Russian gas chromatograph made by SDB «Chromatec» Crystall-5000M Signal registration from 4 channels using digital interface, total temperature programme and zone states control

  15. LC / HPLC system«STAYER» with CONDUCTOMETER DETECTION SYSTEM Our full support of NEW LC instrument made by Russian company «Aquilon» http://main.icp.rssi.ru/aquilon/ “STAYER”Signal acquistion from conductometer.Full control from 1 to 4 pumps either in isocratic and gradient mode.

  16. “Tswett-800“ last development fromJS “Tswett” - Russia. Our full support for new gas chromatograph made by JS “Tswett” -“Tswett-800”. Signal registration from both channels over digital path, total temperature programme and zones state control.

  17. Chromatographs of“Tswett-500“ series JS “Tswett” - Russia. Connection using ADC Lnet.Up to 16 devices simultaneously. Signal registration directly from detector (FID, NPD, ECD).No need in stock amplifiers.Special built-in amplifier for TCD.Both channels signal registration.

  18. Software developed using modern programming technologies. UniChrom works under 32-bit OS Windows 9x™ and Windows NT™ using multitasking and multithreading advantages. Small memory consumption, high processing speed, task paralleling,high reliability.

  19. Multidocument windowed interface with modern look and feel • Simplicity and convenience at work • Viewing and processing chromatograms during acquisitions

  20. Easiest way working with GC instruments.All chromatographs for YOU in common style.

  21. LC / HPLC Only principal differences have sense!

  22. Мultilayered chromatograms allow visual comparison so You can quickly adjust chromatographic method parameters. Chromatogram layers can be copied from one window to another.

  23. Full peak information • Add peak to calibration sequence with single mouse click! • Calculation of volume, mass and molar concentrations

  24. Calibration curves made automatically when You point a peak as “calibration point”. Concentration dependencies built either for peak area and peak height. At graph shown RMS in concentration units.Calibration curves can be transferred to Microsoft Word™ or Excel™ as Graphs or as Tables.

  25. Built into UniChrom LIBRARIES and support for external tables from Microsoft Excel and Microsoft Access allows You identify components in chromatograms no matter what complexity.

  26. Full chromatographic peak information. Especially for article authors and analytical methods developers. Pharmaceutical parameters you can get here!

  27. Simple and Effective spectrum processing methods. If You wish - the processing and calculation sequence is recorded and later can be played automatically when chromatogram registration completes.

  28. Report creation in Microsoft Office™. Reports made upon Microsoft Word™ and Excel™ templates using DDE or OLE Automation. Inside of templates You can modify calculation algorithms and presentation of Your data.

  29. Report Templates being created in Microsoft Excel Chromatographic Peak Data gets=directly to cellsof MS Excel Sheet.

  30. Form and Content of Report Pagesalways conforms Your Requirements!

  31. Standard concentration calculation methods. It is possible to use UniChrom extensions (Plug-Ins) to createcustom data processing methods, and also as midware to connect to industrial information system.

  32. Report example created by UniChrom extension - “Detailed Hydrocarbon Analysis” into Microsoft Excel™ Distillation curve of automotive petrol. Curve built using individual component analysis data (DHA)

  33. Dynamic Signal range of ADC LNet 107 Impurity 1- 0.00001% BENZENE - 99.90352%

  34. 100% BENZENE - 99.90352% Impurity 1- 0.00001%

  35. 10-1 % BENZENE - 99.90352% Impurity 1- 0.00001%

  36. 10-2 % BENZENE - 99.90352% Impurity 1- 0.00001%

  37. 10-3 % BENZENE - 99.90352% Impurity 1- 0.00001%

  38. 10-4 % BENZENE - 99.90352% Impurity 1- 0.00001%

  39. 10-5 % BENZENE - 99.90352% Impurity 1- 0.00001% Impurities at background of BENZENE peak Division “Cyclohexanone-1” of “Azot” plant - City of Grodno, Belarus BENZENE made by “NAFTAN” plant - City of Novopolotsk, Belarus

  40. Using UniChrom 97 the following analytical methods were deployed : Determination of basic petrol parameters (MVI No MN 998-99) using only one chromatographic analysis: quantitative components analysis (conforms ASTM 5134), quantitative PIANO analysis (paraffins, iso-paraffins, aromatics, naphtenes, olefins) (conforms to GOST 6994, 8997, 2070 and ASTM 5134, 5580), quantitative oxygenates analysis (esters and alcohols) (conforms ASTM D 4815), research octane number (conforms GOST 8226 and ASTM 2699), motor octane number (conforms GOST 511 and ASTM 2700) fractions content (conforms GOST 2177, D86 and ASTM 3710), saturated vapour pressure (conforms GOST 1756, EN12 and ASTM 2889), density (conforms GOST 3900 and ASTM 4052).

  41. Using UniChrom 97 the following analytical methods were deployed : Determination of basic petrol parameters (MVI No MN 998-99) using only one chromatographic analysis: Deployment at Central Lab of JS «Mazyrsky NPZ» Oil Refinery Mrs. Nadezhda N. Gremyako +375-(023)-51-532-73, At Central Lab of JS ”LUKOIL-Odessa NPZ” Oil Refinery Mrs. Lydia M. Maksimenko - Ukraine, Odessa, 34-09-16 At laboratory of State Expert Criminalystic Center of Belarus Home Office Mrs. Yana L. Luchinina +375-17-229-76-70, At of automotive petrol testing laboratory of Belarus State University Mr. Arkadi L. Mazanik +375-17-226-25-17.

  42. Is shipped in four languages: • (ENG) English Great Britain • (DEU) German Standard • (RUS) Russian • (BEL) Belarusian

More Related