Goodson tools and supplies for engine builders
Download
1 / 17

goodson tools and supplies for engine builders - PowerPoint PPT Presentation


  • 280 Views
  • Updated On :

GOODSON Tools and Supplies for Engine Builders. Calibrating and Maintaining Your Precision Machinists Level. Replacing the Vial. Step One Remove the 3/8” top nut Be sure to leave the bottom nut in place . Replacing the Vial. Step Two Remove the slotted screw on the opposite end completely.

Related searches for goodson tools and supplies for engine builders

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'goodson tools and supplies for engine builders' - Faraday


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Goodson tools and supplies for engine builders l.jpg

GOODSONTools and Supplies for Engine Builders

Calibrating and Maintaining Your Precision Machinists Level


Replacing the vial l.jpg
Replacing the Vial

Step One

  • Remove the 3/8” top nut

  • Be sure to leave the bottom nut in place

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Replacing the vial3 l.jpg
Replacing the Vial

Step Two

  • Remove the slotted screw on the opposite end completely

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Replacing the vial4 l.jpg
Replacing the Vial

  • Spherical chamfered end mounts with screw and spherical washer

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Replacing the vial5 l.jpg
Replacing the Vial

  • The straight, non-chamfered hole mounts on the stud.

  • Be sure the bottom nut is in place before placing the replacement vial.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Replacing the vial6 l.jpg
Replacing the Vial

Step Three

  • Tighten the screw to only 1 to 2 inch pounds, maximum

    NOTE: If you get the screw too tight at this time, you risk breaking the vial as you adjust the leveling nuts (step eight)

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Replacing the vial7 l.jpg
Replacing the Vial

Step Four

  • Install the adjuster nut finger-tight at this time.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Replacing the vial8 l.jpg
Replacing the Vial

Step Five

  • Uncover the vial and prepare to calibrate the level

    NOTE: Always store the level with the vial covered.

    While replacing the level vial assembly, be careful and keep the vial cover closed.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level l.jpg
Calibrating the Level

With your new level vial installed, you are now ready to calibrate the level

Select a flat smooth surface. Ideally a machined surface such as the table of a guide and seat machine or head resurfacer.

Clean the surface and remove any nicks.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level10 l.jpg
Calibrating the Level

Step Six

  • Use a pencil or Sharpie to draw a line around the level base

  • Use this outline to place the level in the same place each time you rotate the level end to end while calibrating.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level11 l.jpg
Calibrating the Level

Step Seven

  • Rotate the level 180˚ (end for end) and observe where the bubble aligns each time. You will be splitting the difference as you adjust the leveling nuts.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level12 l.jpg
Calibrating the Level

Step Eight

  • Adjust the nuts to raise or lower the vial bubble.

    NOTE: Always raise and lower the nuts simultaneously. Maintain a slight locking pressure on the level mounting ear.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level13 l.jpg
Calibrating the Level

Raise this end 1/2 of the difference (see step seven)

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level14 l.jpg
Calibrating the Level

This is the result of the adjustment made using the readings observed in step seven.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrating the level15 l.jpg
Calibrating the Level

Success!

  • When you can rotate the level 180˚ (end to end) and the reading repeats, your level is calibrated.

    NOTE: You do NOT need to have the bubble at the center of the level for it to be calibrated. You must only repeat the reading when rotating end for end.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Calibrate the level l.jpg
Calibrate the Level

Step Nine

  • Snug down the fasteners. DO NOT over tighten!

  • Check your readings to be sure nothing has moved. If it has, repeat adjustment procedures.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


Level your work l.jpg
Level Your Work

You are now ready to level your work.

When leveling, always back level. Rotate your level 180˚ to be sure it repeats.It’s quick insurance that your level is remaining true.

Toll Free: 1-800-533-8010 Phone: 507-452-1830: Web site: www.goodson.com


ad