1 / 29

Energy Systems with Dupline

Energy Systems with Dupline. Dupline-Online. Dupline-Online A new c oncept for automatic data aquisition from local or remote facilities by the use of GSM technology, the Internet and LAN’s Access to real-time and historical data via Central Server running on Internet/LAN

zanna
Download Presentation

Energy Systems with Dupline

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Energy Systems with Dupline Jens Neigaard

  2. Dupline-Online • Dupline-Online • A new concept for automatic data aquisition from local or remote facilities by the use of GSM • technology, the Internet and LAN’s • Access to real-time and historical data via Central Server running on Internet/LAN • Export of data to administrative IT systems • Alarms via SMS messages and E-mails • Complete solution with hardware and software Jens Neigaard

  3. Apartment owners Service Provider Acquisition of consumption data from Buildings Jens Neigaard

  4. Acquisition of consumption data from Buildings • Dupline-Online Services • Automatic aquisition of consumption data from a large number of apartments via GSM or the Internet • Monitoring of Energy, Water, Gas and Heating consumption • Consumption data are saved in central database enabling • export to billing software performing automatic print-out of • monthly bills per apartment • Each lodger can follow his own consumption of Energy, Water etc. in Euro/$ Histograms on a daily basis • Dupline-Online can also provide monitoring of alarms in the Building, automatic lighting control, remote control of heating, and temperature and humidity measurement Jens Neigaard

  5. Dupline-Online Basic Elements • Dupline Fieldbus • - collects the data from the field • Dupline Data Logger • - Make event and time based loggings as programmed • - Sends the Log Records to the Dupline-Online • Database via GSM or via Internet/LAN • Central Dupline-Online WebServer • - Provides data access via Internet/LAN for • individual users through user name and password • Users existing PC’s • - Several users can access data via std. browser from • any PC connected to the Internet/LAN Jens Neigaard

  6. Dupline Product Overview Jens Neigaard

  7. Dupline - 15+ years of experience - 100.000+ installations WW Jens Neigaard

  8. Basic Components : • Communication media • Input modules • Light switch, temp sensor • Output modules • Relay, dimmer, aktuator • The Controller Unit Jens Neigaard

  9. Dupline ASIC chip : • The ASIC chip combines the latest technology with the bus experience gained by Carlo Gavazzi • The Dupline ASIC do not need a costly transceiver circuit - only a few passive components to interface to the bus • The small physical size makes it possible to design very compact modules with a very low power consumption Jens Neigaard

  10. Dupline Addressing Scheme Channels: 1 ... 8 I/OAddresses: A1, A2, A3 .. A8, B1, B2 .. P7, P8 Groups: A ... P Jens Neigaard

  11. Dupline Features • Easy handling • Plug-and-play coding and testing • Easy wiring • No PC required • Steep learning curve • Electricians can install and maintain systems Jens Neigaard

  12. Dupline Features • Highly flexible • Easy to enhance or change a system • An address can be activated from multiple points • in the system • An address can be read from multiple points in • the system • Key-feature in Building Automation Jens Neigaard

  13. Line Configuration Star Configuration Ring Configuration Combined Configuration Dupline Features • Free Topology • Makes planning and installation easier • Makes future enhancements easier • Key-feature in Building Automation Jens Neigaard

  14. Dupline Features • Transmission over long distances • Up to 10 km without Repeater • Un-limited distance when Repeaters are cascaded • Key-feature in Water Distribution, Sewage Systems, Irrigation Systems, Railway Systems Jens Neigaard

  15. Dupline Features • Noise-immune and robust system • Low carrier frequency allows powerful filtering • High Common Mode Rejection Ratio • No need for special cable, shield not required • Runs in parallel with power cables • Existing cables can be used • No terminations needed for distances < 1.5 km Jens Neigaard

  16. Dupline Features • Bus-powered products • Cost-effective installation • Enables transmission of signals from points • where no power is available • Key-feature in Alarm Systems and • Building Automation Jens Neigaard

  17. Dupline advantages vs. RS485 • Long distance • Free topology • High Noise Immunity • Easy handling • Easy to configure • No need for special cable • No shield and cable terminations required • Counters can be combined with wide Dupline product range, e.g. for machine monitoring and load control • Easy to expand an installation in steps as need appear Jens Neigaard

  18. Profibus-DP LonWorks Ethernet Modbus Electricity Gas Water CARLO GAVAZZI 1.1 1.1 1.1 1.1 1.1 1.5 1.5 1.5 1.5 1.5 2.1 2.1 2.1 2.1 2.1 2.5 2.5 2.5 2.5 2.5 1.2 1.2 1.2 1.2 1.2 1.6 1.6 1.6 1.6 1.6 2.2 2.2 2.2 2.2 2.2 2.6 2.6 2.6 2.6 2.6 R Dupline Gateway CARLO GAVAZZI ON LINE BUSY FAULT G 4420 7401 230 G 4420 7401 230 G 4420 7401 230 G 4420 7401 230 G 4420 7401 230 1.3 1.3 1.3 1.3 1.3 1.7 1.7 1.7 1.7 1.7 2.3 2.3 2.3 2.3 2.3 2.7 2.7 2.7 2.7 2.7 Dupline Bus 1.4 1.4 1.4 1.4 1.4 1.8 1.8 1.8 1.8 1.8 2.4 2.4 2.4 2.4 2.4 2.8 2.8 2.8 2.8 2.8 Dupline advantages vs. RS485 Data can be transferred to other bus systems from one point Pulse Output Pulse Output Jens Neigaard

  19. Dupline-EM4 Plug-in Module • Features • Fits into slot B of EM4 Energy Meters and • WM22 Power Analyzers • Dupline transmission of actual internal • energy value (active/reactive) • 2 x S0 count inputs for water/gas etc. • Counter values are saved in non-volatile • memory • Each Energy and Counter value can be • enabled/disabled for transmission • Address selection and configuration via • DIP-switches • Energy and Counter values can be read • from Master Generator via ModBus • (or via Fieldbus Gateways) Jens Neigaard

  20. Dupline Counter Module • 4 x S0 count inputs • 128 count values on one Dupline network • Uses groups B-C-D-E-F, thereby leaving • 88 channels available for other signals • Counter values can be read from • Master Generator via ModBus (or via • Fieldbus Gateways) • Counter values are saved in non- • volatile memory • Reset possibility for individual counters • Possibility for Machine ”ON-time” • summarizing • DIN-rail Mounting • 115 VAC / 230 VAC / 24 VDC Power Supply Jens Neigaard

  21. Dupline-EM4 Plug-in Module • Advantages vs. Pulse Counter • Reading of actual energy value ensures • that the values on the bus and in the • display are the same • No loss of energy count pulses • No possibility to tamper with count inputs • in billing systems • Cost-effective and space saving solution • for energy consumption and water/gas • counting Jens Neigaard

  22. The Data Logger • Data Logger funktions • Programmable logging functions • Event- and Time-based logging • Logging of digital, analog and counter values • Transmission of logged data via GSM Modem (SMS) or the Internet • Built-in programmable functions (logic functions, timers, real-time clock control, master functions, set-points, alarm system and more) • Option for radio controlled clock • Unique ID code G3800X036 Jens Neigaard

  23. The Data Logger • The simple steps required to set up the system • Select transmission method • (Internet/LAN and/or GSM) • Select which signals shall be logged • Select the interval between time-based logs • Download configuration to Data Logger • Generate export-file • Register the Data Logger on the central server Jens Neigaard

  24. Option #1 • Use of Carlo Gavazzi’s Central Server • A Central Server installed by Carlo Gavazzi runs www.dupline-online.com • Simple solution for the end-user without need to invest in new IT equipment • Each registered user of Dupline-Online pays a yearly fee according to the number of Data Loggers he has registered • 2 weeks free trial period Jens Neigaard

  25. Option #2 • User installs own Central Server • The users buys the Dupline-Online Software for installation on own Server • One-time fee based on the no. of Data Loggers the Software can handle (option for buying increased capacity) • Optional customized version based on offer Jens Neigaard

  26. CARLO GAVAZZI CARLO GAVAZZI CARLO GAVAZZI CARLO GAVAZZI CARLO GAVAZZI CARLO GAVAZZI R R R R R R MODE MODE L L L L DOWN DOWN Dupline Dupline ENTER ENTER WM2-DIN WM2-DIN WM2-DIN WM2-DIN POWER ANALYZER POWER ANALYZER POWER ANALYZER POWER ANALYZER UP UP Mastergenerator Mastergenerator ON LINE BUSY FAULT ON LINE BUSY FAULT Dupline-Online running on a Factory LAN I/O-module User data access via std. browser EM4/ WM22 I/O-module Master Generator Ethernet adaptor EM4/ WM22 Factory LAN Ethernet adaptor Central Server running Dupline-Online User data access via std. browser Jens Neigaard

  27. Dupline-Online running on a Factory LAN • Features • Data are gathered using the existing Factory LAN • No limit to the number of Dupline networks that can • be connected to the LAN • The gathered data are directly available for the • administrative IT-system at any point in the factory via EXCEL-files or SQL-queries • Alarm recording and messaging (SMS/E-mail) • Extremely flexible for future enhancements Jens Neigaard

  28. Dupline-Online running on a Factory LAN • Register energy consumption on individual machines, processes or sections of production • - Allocate energy cost to production batches • - Allocate energy cost to departments • Overview of energy consumption can be used as • input for energy saving strategy • - Energy savings are documented • Switch loads like lights, ventilation, heating etc • Keep total energy consumption below allowed • levels • - Save energy • - Sequenced start-up of machines Jens Neigaard

  29. Dupline-Online running on a Factory LAN • Register Machine Run Times • - Improved planning of preventive maintenance • - Enables analyses of reasons for machine down-time to be used for improvement of machine efficiency • - Overview of Machine Efficiency can be used in production planning • Immediate central/local reporting of machine alarms • - Reduced machine downtime • Register Machine Alarms • - Enables analyses of machine and operator performance Jens Neigaard

More Related