An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WLM - SYSTEM Network survey and leak zone detection … Reducing water loss sustainable … Detecting leaks immediately ... MWM – Martinek Water Management GmbH Mozartstraße 23 A – 6845 Hohenems Austria Tel.: +43 5576 75510 Fax : +43 5576 78170 E – Mail : office@martinek.org Internet : www.martinek.org

  2. Cost effective chamber installation • Installation without any interruption • Manufactured by • HAWLE Armaturen GmbH • Easy installation and dismantling • No chamber necessary; just a street cap

  3. Installation of a pipe saddle • Installation like a house connection • Use a 38mm driller

  4. Installation of the covering pipe • This part is available in length from 1 to 2,5 m (extra sizes possible) • Length can be cut on site • adapt to the local situation

  5. Installation of WLM-Sensor • Cable will be put through the extension of the sensor and plugged to it. (all connections are IP68 up to 10m) • The extension can also be cut on site to the needed length

  6. Top of the extension • Everything will be covered to avoid water entrance • A clamp ring will be fixed on the extension for the right depth of the sensor in the pipe

  7. Install the sensor under pressure • A special tool will be used to install the sensor under pressure • Safety has first priority! • Installation is finished

  8. Only a small street cap • Only a small street cap will be on the top • Highly vandalism protected!

  9. Aerial at the top of a street light Installation in a street cap:12 V charger, modem battery. Up to ca. 15 m WLM-System Connection to a street light