1 / 11

FIT Iseg

FIT Iseg. DCS Training Session 2.2. Overview. Hardware Iseg EHQ F6 xxx – F modules Software Tools isegCANHVControl iseg HV OPC configuration FIT iseg Integration Control Watchdog. iseg EHQ F6 xxx – F modules. Not HV, because we are below 1kV  Data sheet 16 channel Vmax: 700 V

warner
Download Presentation

FIT Iseg

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FIT Iseg DCS Training Session 2.2

  2. Overview • Hardware • Iseg EHQ F6 xxx – F modules • Software • Tools • isegCANHVControl • iseg HV OPC configuration • FIT iseg • Integration • Control • Watchdog Joachim Schultes

  3. iseg EHQ F6 xxx – F modules • Not HV, because we are below 1kV  • Data sheet • 16 channel • Vmax: 700 V • Imax: 4 mA • INHIBIT per channel Joachim Schultes

  4. Iseg tools: isegCANHVControl • Displays all scanned devices (only for configured CAN) • Colour coded • Green: no alarm • Yellow: alarm, not selected • Red: alarm and selected • Two modes of operation • EHQ • EHS • Actual it is necessary to operate the modules in EHQ mode • Per iseg modules two nodes are visible (each 8 channels) • Low level operation (debugging) possible Joachim Schultes

  5. Iseg tools: iseg HV OPC configuration • Manage configuration file for OPC server • Load old file first • Delete not existing nodes • Search for nodes on CAN • Add missing ones • Save file • Two modes of operation • EHQ (displayed with xxxx 07) • EHS (displayed with xxxx 25) • Actual it is necessary to operate the modules in EHQ mode Joachim Schultes

  6. OPC server • Communication via CAN(Peak CAN interface) • CAN lines have to be defined inside “isegHVOPCServer.ini” • Configuration managed by “EHQ3216Srv.opc” files created by iseg HV OPC configuration • CAN line • Node Id • Operation type • ... Joachim Schultes

  7. FIT iseg: User Interface and Integration • User Interface • Shortcut on desktop (preferred) • Additional manager inside the PVSS console • Integration • Crate name has to be unique • Node Id as scanned with “iseg HV OPC configuration“ tool, includes can line Joachim Schultes

  8. FIT iseg: control • Displays main information of the 8 channels of one CAN node (half iseg module) • Status of channel can be • “OFF” • “ON” • “INTERLOCK” • “ON-Itrip/Ilimit” • Ramp speed in % of NominalV [7 V/sec] • IV curve possible with selected channel (be aware of modularity) Joachim Schultes

  9. FIT iseg: control settings • Read/write • GeneralFineAdjust • GeneralKill [0 ISet, 1 ITrip]!!! • GeneralSafetyLoop [0 opened, 1 closed] • StatHardwareILimit [bit pattern] • StatHardvareVLimit [bit pattern] • StatINHIBIT [bit pattern] • StatITrip [bit pattern] • ErrThreshold • Read only • GeneralStable [all channel stable] • GeneralStat • GeneralSumError • GeneralSupplyTemp • ADCFilterFrequency • Alarm • Alive • AllocChn • BitRate • ChnNotOk Joachim Schultes

  10. FIT iseg watchdog: all OK • Separate process monitoring • Wiener Control Manager (self monitoring) • Wiener OPC DA Client, sends and receives data from and to the OPC server and communicates them to PVSS. • Wiener OPCS, which is the OPC server communicating with the crates. • Wiener crates themselves • Monitoring of devices can be disabled Joachim Schultes

  11. FIT iseg watchdog: pending alert • OPC client not running(OPC server status unknown) start OPC client (-num 3) • OPC server not running (OPC client running) check config file, start OPC server • Device not responding (status unknown) check connections and power use isegCANHVControl check configuration Joachim Schultes