50 likes | 131 Views
Enhance the implementation and performance of DHQDS by reducing nominal voltage for RQX R1 with specific hardware and software modifications, including capacitor bank adjustments and transformer voltage changes. Acknowledging hardware consultants for their contributions.
E N D
Implementation and performance of the DHQDS with reduced nominal voltage for RQX.R1 R. Denz Acknowledgements: K. Dahlerup-Petersen, J. Mourao
Hardware and software modifications Capacitor bank: 6 x 6 mF instead of 6 x 4.7 mF 850 V charging voltage Mains transformer: Secondary voltage rating changed QPS supervision: QPS_OK setting changed for signal U_HDS_2_Q2 to 0.95 * 800 V = 760 V
Quench heater discharge MQXA modified MQXB U_HDS_2_Q2 = 850 V 820 V across heater strip (Rcable = 0.7 Ω , Rheater = 19.0 Ω) Uearth = |410 V| during nominal discharge Uearth_max = |820 V| during discharge and capacitor bank fuse blown
Quench heater discharge MQXA modified MQXB 11.5 Ω MQXA 19.7 Ω