A primer course of experimental particle and nuclear physics . Advanced experiment Tran Thien Thanh Tran Duy Tap. OSAKA UNIVERSITY - 2009. OUTLINE. 1. Background. 2. Experiment. 3. Discussion. 1.Background. Purpose. A life time of the first excited state of 57 Fe

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Advanced experiment Tran Thien Thanh Tran Duy Tap' - vega


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1
A primer course of experimental particle

and nuclear physics



Advanced experiment

Tran Thien Thanh

Tran Duy Tap

OSAKA UNIVERSITY - 2009

slide2
OUTLINE

1. Background

2. Experiment

3. Discussion

slide3
1.Background

Purpose

  • A life time of the first excited state of 57Fe
  • Calibration of time and channel relation
  • Measurement of the first excited state of 57Fe
slide5
2. Experiment

Procedures

Stage 1: Energy calibration

Stage 2:Calibration of time – channel relation

Stage 3:Measurement of a life time of first excited state of 57Fe

slide6
Amplifier

NaI(Tl) and PMT

HV power supply

MCA

2. Experiment

  • Stage 1: Energy calibration

57Co

slide7
14,4KeV

122KeV

2. Experiment

slide8
HV

Amplifier

Delay Amp

Start

TAC

Stop

MCA

NaI(Tl)

57Co

PMT

SCA

2. Experiment

  • Stage 2: Calibration of time and channel relation

Diagram of the time – channel relation

slide9
2. Experiment
  • Stage 2: Calibration of time and channel relation
slide10
2. Experiment
  • Stage 2: Calibration of time and channel relation

A= -0,06667  0,22874

B = 0,26388  0,00074

slide11
HV - A

AMP

SCA

Discrimator

57Co

Start

TAC

Stop

MCA

AMP

SCA

Discrimator

HV - B

2. Experiment

Stage 3:Measurement of a life time of first excited state of 57Fe

slide12
2. Experiment
  • Stage 3: Measurement of a life time of first excited state of 57Fe
slide13
2. Experiment
  • Stage 3: Measurement of a life time of first excited state of 57Fe

A= 2,19815  0,02432

B = -0,02734  0,00020

slide14
3. Discussion

Reference T1/2r = 98ns