1 / 6

Electrical Asset Monitoring T401 - Rugged Monitoring

T401 gives state-of-the-art condition monitoring solution for industries with huge electrical infrastructure. It can analyze the data and obtain the predictive diagnostics to detect any serious faults before a breakdown occurs. T401 is precisely designed to monitor wide range of electrical asset types and to provide a greater visibility into the assets.

rugged2
Download Presentation

Electrical Asset Monitoring T401 - Rugged Monitoring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. T401 TRANSFORMERMONITOR ROBUST |RELIABLE |RESPONSIVE

  2. T401MONITORINGFUNCTIONS TransformerHealthAssessment RealTimeMonitoringandAdvanceControl RUGGEDSOFTWARE • RemoteMonitoringandControl • InsulationLifeEstimation • OverloadCapacity • Bubbling Temperature • MoistureinInsulation • RealtimeAlarmandNotifications • EasyIntegration • TransformerMonitoring • OilTemperature • WindingTemperature • LoadCurrent • OLTCTapPosition • LiquidLevel • TankPressure FUNCTIONALITY • BushingMonitoringIntegration • TanDelta(PowerFactor) • Capacitance DryTypeTRMonitoring PDMonitoringIntegration TransformerMonitoring • PDAmplitude • PDDischargeRate DissolvedGasanalyzerIntegration • SinglegasDGA • Multi-gas DGA • Moisture CoolingControl • Fan/PumpStatus • FanBankMotorCurrent • CoolingEfficiency • FanbankExercise VaultMonitoring • OLTCMonitoring • OilTemperature • OilLevel • OLTCTapPosition • OLTCMotorCurrent • ContactWear 02 03

  3. T401SYSTEM ARCHITECTURE KEYBENEFITS Hardwired(Analog/Digitals) ARCHITECTURE SerialRS-485(Modbus/DNP3.0/IEC60870-104) Hardwired(Analog/Digitals) FOavailablewithT501 1 2 3 4 5 6 7 Sensors on Transformer FiberOptic Temperature Transformer ControlCubicle Sensoron OLTC/RTCC Dissolved GasAnalyzers Bushing& PDMonitor Partial Discharge Monitor CoolingControl Certifications • ATEX • Lloyds • CE/RoHs 1.OTI,WTI,RTD,PRD,Breather, Buchholz Relay,LLG/OLI,Pressure Sensor etc. 1 TransformerControlCubicle OLTCandRTCCPanel CoolingSystem and Control Cabinet DissolvedGasAnalyzer BushingMonitoring PartialDischargeMonitor 6 1 2 7 1 Variants • Offshore/Marine • EthernetRedundancy:PRP • EnterpriseMonitoringSoftware 4 1 3 5 4 04 05

  4. T401FEATURES ComprehensiveFeaturestoMeetMarketDemand • DesktopandWebClient • RemoteConfiguration • AdvancedVisualization • DataLogging,Reporting • SupportsIndustryStandardProtocols • Customizationavailableonrequest • Secureaccesstodata&Configuration • MultipleLanguageSupport RUGGEDSOFTWARE • RELAYOUTPUTS • 08xFormCRelaycontacts • NO-C-NC • Coolingcontrol • Alerts/Alarms POWERINPUT -24/48Vdc FEATURES - Power Supply Unit / Adaptor provided as Accessories (OPTIONAL) • LOCALDISPLAY • IndustrialGradeLED • CurrentValuesofallParameters • LEDINDICATORS • PowerON/OFF • SystemFault • Alarm&Log ANALOGOUTPUTS • USBPORT • Configuration& Troubleshooting • DataExport • MicroSDCard • 04xUserProgrammable • CurrentOutput(4-20mA) • VoltageOutput(0-5V/0-10V) • ANALOG/DIGITALINPUTS • 08xConfigurableInputs • RTD(PT-100),Potentiometer • ACCurrent(Clamp-OnCT),DCcurrent(4-20mA) • Digital(DryContacts) • AC/DCVoltage • SERIALPORT(RS-485) • DataInput/ • outputIntegration • ModbusProtocol • DNP3.0Protocol • IEC60870-104Protocol • ETHERNETPORTS • 02xconfigurablePorts(RJ-45/SFP) • FullRedundancy • PRPProtocol • -Modbus,DNP3.0,IEC60870-104andIEC61850 06 07

  5. TECHNICALSPECIFICATIONS PRODUCTDRAWINGS 237.00mm [9.33in] 175.10mm DRAWINGS 4XM8X1.0- [6.89in] 96.10mm [3.78in] 187.54mm [7.38in] 187.54mm [7.38in] SPECIFICATIONS 267.54mm [10.53in] 65.00mm [2.56in] 65.00mm [2.56in] Weight:2Kilograms ORDERINGCODE ModelNumber BasedonInput ChannelConfiguration NumberofAnalogOutputs 0=NoAnalogOutputs 4=4AnalogOutputs - MemorySize 4=4GB 8 = 8GB T 4 01 E A R M EthernetProtocols 0=NoEthernet DS0026R05_T401TnD_EN_A4 NumberofRelayOutputs 0=NoRelayOutputs 8=8RelayOutputs 1=EthernetBoardRJ45 2=EthernetBoardRJ45&SFP 08 09

  6. RUGGEDMONITORING RUGGEDMONITORING Certification ISO9001 ISO14000 ISO45001(OHSAS18000) ISO17025 Certification NISTCertification ATEXCertification RuggedMonitoring Services RuggedMonitoringprovides customizationofsensors,monitors &software.Inadditionweoffer on-sitecommissioningservices, maintenancecontractsandtechnical supporttoallcustomersworldwide. Website www.ruggedmonitoring.com Visitustoseemore Solutions https://www.ruggedmonitoring.com/fibre-optic-temperature-solutions Blogs https://www.ruggedmonitoring.com/blogs/1 Video https://www.ruggedmonitoring.com/fiber-optic-videos ApplicationNotes https://www.ruggedmonitoring.com/downloads/application-notes/1 Software https://www.ruggedmonitoring.com/downloads/dcsoftware TechnicalDrawings https://www.ruggedmonitoring.com/downloads/dctechnicaldrawings ProductManuals https://www.ruggedmonitoring.com/downloads/dcproductmanual Ebook https://www.ruggedmonitoring.com/fiber-optic-technical-ebooks AboutRuggedMonitoring Industryleadingteamoffiberoptic expertswith100+yearsofcombined experiencecommittedtodelivering customizablesolutionsforchallenging applications.Weofferarangeofreliable, highperformance,customizablesensors andmonitoringsolutionsthatare immunetoexternalinfluence. SocialMedia https://www.linkedin.com/company/ruggedmon/ ContactUs Address 1415Frank-Carrel,Suite230, Quebec,QC-G1N4N7, CANADA ContactDetails Phone:+1-418-767-0111 Email:info@ruggedmonitoring.com https://www.facebook.com/ruggedmon https://www.instagram.com/ruggedmon/ https://www.youtube.com/c/ruggedmonitoring https://twitter.com/ruggedmon https://in.pinterest.com/ruggedmonitoring/ https://www.xing.com/companies/ruggedmonitoring 2018 Rugged MonitoringCompany.All rightsreserved.Information subjectto changewithoutnotice. Alltrademarks are propertiesoftheirrespectivecompanies,asnotedherein. 10

More Related