DPA UPScale TM RACK Mountable & Modular Continuous Power Protection Availability

DPA UPScale TM RACK Mountable & Modular Continuous Power Protection Availability. The multimaster technology – DPA UPScale. Decentralized Parallel Architecture DPA. Decentralized Parallel Architecture (DPA) TM from NEWAVE.

rowena
Download Presentation

DPA UPScale TM RACK Mountable & Modular Continuous Power Protection Availability

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DPA UPScaleTM RACK Mountable & ModularContinuous Power Protection Availability The multimaster technology – DPA UPScale

  2. Decentralized Parallel Architecture DPA Decentralized Parallel Architecture (DPA)TM from NEWAVE Decentralized Parallel Architecture (DPA)TM was designed to distribute virtually the entire UPS Hardware and Software into modules in order to reduce the Single Points of Failures (SPOF). DPA includes distributed MAINS 2 MAINS 1 • Control Panel on Module DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH • CPU • Power Unit DPA BATTERY PACKS • Static bypass switch DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH and • Separate Batteries DPA BATTERY PACKS DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA BATTERY PACKS CRITICAL LOAD DPA UPScale

  3. Decentralized Parallel Architecture DPA DPA UPScaleTM HIGHLIGHTS and Benefits • High level of decentralization • Multi Master and Slave Technology through a simplified BUS Communication • Full redundancy on inverter • Full redundency on Static Bypass Switch (SBS) DPA UPScale

  4. Safe-Swap modules The DPA UPScaleTM Modules are fully independent and are composed of all major hardware and firmware building blocks: • CPU (Central Processing Unit) • All power circuits (rectifier, inverter, battery charger) • Static switch and static switch control • Power Management Control Panel In-built Display Static Switch Control unitDisplay Inverter Rectifier Booster Battery DPA UPScale

  5. Enhanced Serviceability • Safe-Swap Modular design, minimize service and maintenance costs • One person can easaly exchange the low weight modules • MTTR reduction maximize your power protection availability • No need of skilled personnel on site • Non need of spares, only modules for an easy fault recovery DPA UPScale

  6. 10kW / 10kVA 20kW / 20kVA DPA UPScaleTM RI 10-80 kW Rack-Independent Models UPScale RI 11 UPScale RI 12 UPScale RI 10 19” UPScale Modules : UPScale M10 UPScale M20 HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 488x665x732(15HU) WxHxD 488x487x732 (11Hu) WxHxD 488x487x732 (11Hu) 1 x 40 x 7.2/9AhTotal 40 blocks No internal Batteries 2x40 x 7.2/9AhTotal 80 blocks DPA UPScale

  7. 10kW / 10kVA 20kW / 20kVA DPA UPScaleTM RI 10-80 kW Rack-Independent Models UPScale RI 40 UPScale RI 20 UPScale RI 24 UPScale RI 22 19” UPScale Modules : UPScale M10 UPScale M20 HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 488x665x732(15HU) WxHxD 488x798x732(18HU) WxHxD 488x1153x732(26HU) WxHxD 488x798x732(18HU) 2x40 x 7.2/9AhTotal 80 blocks 4x40 x 7.2/9AhTotal 160 blocks No internal Battery No internal Battery DPA UPScale

  8. Features: DPA UPScale RI 10-80 kW • Integratable in any 19” rack • DPA with Safe-Swap Modules (SSM) • Exceptionally low Module weight • Safe Swap extendable from 10-80 kW (4 Modules) • Flexible battery management blocks • Ripple free through battery charger • Distributed control and power • LCD display integrated on Module • Huge Flexibility / Scalability • Easy to install and service • Excellent Input PFC: >0.99 @ 100% load • Low input THDI: < 3% @ 100% load • High conversion efficiency: up to 95.5% DPA UPScale

  9. DPA UPScaleTMBusiness Value of Power Protection With the modular, safe swap UPS systems, you can build your own IT-Facility to meet simultaneously and most accurately: • Higher Availability • Unmatched flexibility to changes • Reduced footprint • Lowest TCO • Product standardization  AND ALL THIS AT BEST POSSIBLE COST DPA UPScale TM DPA UPScale

  10. Thank you for your attention DPA UPScale