1 / 10

T-980 Meeting Dec 3, 2008

T-980 Meeting Dec 3, 2008. Dean Still. Dec 3, 2008 Meeting Agenda. New News (Nikolai) Overview of IHEP goniometer - (Rob) Simulation for best location of proposed Ver Goniometer. (Sasha) Results of last EOS studies - (Dean , Valentina) Plans for next study period (Dean)

rlarsen
Download Presentation

T-980 Meeting Dec 3, 2008

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. T-980 MeetingDec 3, 2008 Dean Still

  2. Dec 3, 2008 Meeting Agenda • New News (Nikolai) • Overview of IHEP goniometer - (Rob) • Simulation for best location of proposed Ver Goniometer. (Sasha) • Results of last EOS studies - (Dean , Valentina) • Plans for next study period (Dean) • PAC paper - author list and subject/abstract (All)

  3. Crystal 2008 Study Plans T-980 has requested 12-20 hours of EOS to reach the following goals: • Measure channeled, volume-reflected and scattered beams as well as beam losses (radiation levels) downstream of the crystal setup in comparison with simulations • Measure channeled • Measured V.R. region • Reliable/ repeatable angles • Collimated channeled beam – Similar results to 2005 data. • Did not attempt to collimate V.R. beam • Compare to simulation –> missing predicted bend angle. • Compare to old data - >width of channel is increased & V.R. Efficiencies down 40%. ?? • No understanding of downstream losses ~ 0 . • Need better instrument at crystal – new pin (maybe gated or new paddles Rick & Todd have ideas) • No profile seen (I think or not yet reported) on Flying wire.

  4. Crystal 2008 Study Plans (2) What's happening in the abort gap? (From Rick) How are the rates of channeled beam (E1LABT) affected by turning off the T.E.L.        A.  Instantaneous (rates immediately after turning off)        B.  After beam accumulates to steady state (~20 min after T.E.L. is off). What happens to the rates (E1LABT) when the duty factor of the T.E.L. is increased/decreased? What happens to bunched beam loss rates (E1LBNC) when the T.E.L is used to compensate for beam-beam effects? (T.E.L. used during bunches)

  5. Crystal 2008 Study Plans (3) • Demonstrate reproducible beam loss reduction in the B0 and D0 in comparison with simulations, aiming at a routine use of the crystal based collimation in the Tevatron stores. • Collimated channeled beam.. ButNo efficiencies at CDF or D0. • Need some more understanding of normal 2 stage efficiencies to compare store to store. • Need better understanding of channeling abort gap beam or how to get and detect channeled bunched beam. • Effects of TEL are not fully explored. • Software is written for automated crystal motion with feedback just need beam testing time. • GOAL SHOULD BE TO GET TO A POINT TO USE CRYSTAL AT BOS - At what point do we consider ready to attempt BOS?

  6. NEXT EOS PLAN • Next EOS should include the following: • Estimate of D49 to Crystal efficiencies at CDF and D0. Find optimal setting points for BOS. • Effects of TEL On/Off – but I need someone to give me some projections on TEL and time. • Flying Wire Scans in Abort Gap. • If some conclusion about settings can be made request BOS (sometime in Nov). • Need approval for BOS –when do we get this.

  7. Plan for Nov 20 to be continued to next EOS • Determine if max displacement and max intensity of channeled particles occur at same angle. Probably not because of mis-cut. • Find equal point for E0CH and E03HCP. • Confirmed feedback for E0CH insertion works. • Find equal point for E0CH and F172HCP. • Collimator using E03 & F172 V.R, VCAP, scattered, channeled beam from crystal. • D49 target vs Crystal. • Flying Wire data in abort gap. • Effect of TEL on the channeled beam.

  8. Normal Collimation Efficiencies Moved E03H and D49 Almost equal E03H 1.5mm Ahead of D49 E1LABT E0LABT E1LABT E0LABT

  9. Effect on Proton Halo Reduction ??

  10. Proposed Abstract for PAC09 • Title: Crystal Collimation Studies at the Tevatron (T-980) • Presenter: A.I. Drozhdin or D.A. Still (whoever going to PAC09) • Authors: G.E.Annala, A.Apyan, R.A.Carrigan, A.I.Drozhdin, T.R.Johnson, A.Legan, N.V.Mokhov, V.Previtali, R.E.Reilly, V.D.Shiltsev, S.Shiraishi, D.A.Still, R.Tesarek, I.Yazynin, J.Zagel • Abstract Bent-crystal channeling is a technique with a potential to increase the beam-halo collimation efficiency at high-energy colliders. First measurements at the Tevatron in 2005 have shown that using a 5-mm silicon crystal to deflect the proton beam halo onto a secondary collimator improves the system performance by reducing the machine impedance, beam losses in the collider detectors and irradiation of the superconducting magnets, all in agreement with simulations. Recent results, obtained with substantially improved goniometer and enhanced beam diagnostics, are reported showing channeling collimation of the ~1-TeV circulating proton beam halo at the Tevatron collider. Comprehensive results of computer modeling are presented which allow further developments of the T-980 experiment towards a robust system compatible with requirements to high-efficient collimation at the Tevatron and LHC hadron colliders.

More Related