1 / 59

Panasonic System Networks PBX SE team

KX-NS1000 Step by Step Guide E1 Adapter / PRI Adapter KX-NS8188 / KX-NS8290. September 11, 2013. Panasonic System Networks PBX SE team. Trunk Adaptor. IP Network. 1. Introduction.

riveraj
Download Presentation

Panasonic System Networks PBX SE team

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KX-NS1000 Step by Step GuideE1 Adapter / PRI AdapterKX-NS8188 / KX-NS8290 September 11, 2013 Panasonic System NetworksPBX SE team

  2. Trunk Adaptor IP Network 1. Introduction When customers want to use IP-Phone mainly for extension and they want to use E1 or more than 2 PRI as trunk, KX-NS1000 version 2 with trunk adapter is recommended.Activation key for IP trunk is not required to connect E1 / PRI adapter.Trunk adapter cannot be connected with other PBX using SIP. PanasonicKX-NS8290 PRI30 SIP Extension PRI30 SIP Trunk (30-ch) KX-NS1000 IP Trunk AK PRI Card KX-NCS0290 215 mm (W)44 mm (H)200 mm (D) 500g SIPSoftphone OtherSIP Phone KX-UT KX-NT

  3. IP Network Reference 2. Stacking Card When customer has Panasonic PBX now, they can add IP capacity and built-in solution using KX-NS1000 version 2 with stacking card KX-NS0130 with keeping current PBX.KX-TDA0131/0132 is installed instead of MPR card.This configuration is useful for new customeralso to increase SLT and so on. After adding KX-NS1000 Before adding KX-NS1000 AnalogCO AnalogCO Direct Connectionlike TDE600 to TDE620 KX-TDE KX-TDE KX-NS1000 CO Card CO Card SC Card SC Card MPR Card EXT Card EXT Card KX-NCS0130 100 % FeatureTransparencylike TDE600and TDE620 SIPSoftphone OtherSIP Phone KX-UT KX-NT SLT KX-DT w/DSS Console KX-DT w/DSS Console SLT

  4. 3. Table of Contents

  5. Chapter 1Overview

  6. Trunk Adaptor Trunk Adaptor Trunk Adaptor 11. Capacity Maximum 256 ch is available for E1 / PRI by adapter and IP trunk. Also useful to provide PRI/E1 with 2-ch Analog CO or 4 BRI. PRI30E1 PRI30 E1 SIPProvider PRI30E1 PRI30 SIP Trunk(30-ch) SIP Trunk(30-ch) SIP Trunk(xx-ch) 256ch AnalogCO SIP Trunk (30-ch) PRI Card CO Card Max. 256ch can be registered to SIP provider or the adapter.

  7. Trunk Adaptor Trunk Adaptor Trunk Adaptor Trunk Adaptor Trunk Adaptor 12. PRI Adapter - Fractional Service Fractional service is also available.<Stand alone> 20chE1/PRI 20ch KX-NS1000 <One-look network> 20chE1/PRI 60chE1/PRI 10chE1/PRI Total 256ch 20ch 10ch 30ch 30ch 16th KX-NS1000in Niseko 1st KX-NS1000in Fukuoka 2nd KX-NS1000in Tokyo

  8. IP Network(VPN) Trunk Adaptor 13. PRI Adapter - QSIG PRI adapter supports ISDN QSIG also to connect with other PBX.Activation key for IP trunk is not required for PRI adapter.Trunk adapter cannot be connected with other PBX using H.323. 192.168.0.101 KX-NS1000 192.168.0.151 PRI Ext 2xx H.323 IP Trunk AK ISDN QSIG Ext 1xx KX-TDA/TDE/NCP or PBX by other maker 192.168.30.101 Ext 3xx DN2IP table (Dial to IP)----------------------------------- Dial 2xx to 192.168.0.151Dial 3xx to 192.168.30.101Dial 4xx to 192.168.40.101 192.168.40.101 Ext 4xx

  9. Trunk Adaptor 14. PRI QSIG – Capacity & Specification H.323 is used for this configuration instead of SIP. KX-NS8290 KX-NS0290 PRI Card KX-NS1000

  10. Chapter 2Specifications

  11. 21. Hardware Appearance Hardware Appearance is as follows. Front Back Wall Mountain Unpack the box and check the items below: Main Unit x 1 Screw x 2 Washer x 2

  12. 22. PoE (Power over Ethernet) KX-NS8188 / KX-NS8290 supports PoE.If PoE is not supported by network, AC adapter is required. KX-A420 for Brazil KX-A239 for others*) These are same model of AC adapter for KX-UT phone.

  13. Trunk Adaptor 23. KX-NS8188 E1 Adapter KX-NS8188 E1 adapter supports following features. E1 KX-NS8188 KX-TDA0188 KX-NS1000 KX-TDE

  14. Trunk Adaptor 24. KX-NS8290 PRI Adapter KX-NS8290 PRI adapter supports following features. “No” because these services by ISDN provider are not popularand PBX can support same feature basically. ConfbyPBX ConfbyISDN ISDN KX-NS8290 KX-NS0290 PRI Card KX-NS1000

  15. Trunk Adaptor Trunk Adaptor 25. Solution with “Back-up Master” Back-up is available automatically for SIP trunk incl E1 / PRIadapter, KX-NT/UT IP-phone. PRI/E1 or SIP Provider Back-up master PBX works as slave PBX usually.But it works as master PBX after master PBX stops working. KX-NS1000 (2nd)Back-up Master SIP Trunk One-Look AK One-Look AK KX-NS1000 (1st)Master KX-UT KX-UT KX-NT KX-NT PRI/E1 or SIP Provider After master PBX stops working, KX-NS1000Back-up Master SIP Trunk One-Look AK One-Look AK KX-NS1000Master KX-UT KX-NT KX-UT KX-NT

  16. Chapter 3Concept of Programmingfor Public Connection

  17. Trunk Adaptor 31. Concept of Programming - Adapter The trunk adapter is PBXwith E1 / PRI trunk and SIP extension.SIP trunk of KX-NS1000 is registered to SIP extension of the adapter.<Programming for the trunk adapter>Software of the adapter is basically same as KX-NS1000. Features except E1 / PRI and SIP extension are removed. Therefore programming method is very similar to KX-NS1000. E1/ ISDN - PRI configuration is same as programming for KX-NS1000 PRI card (KX-NS0290). E1 configuration is same as KX-TDE E1 card (KX-TDA0188). - SIP extension configuration is same as KX-NS1000. But SIP extension is programmed by default. 401 to 430 for E1 / PRI30 401 to 423 for PRI23 PRI E1 / PRI SIP Extension401-430 30ch or 23ch ID 401-430SIP Trunk KX-TDA0188 PRI Card KX-NS0290 KX-NS1000 KX-TDE

  18. Trunk Adaptor 32. Concept of Programming – NS1000 <Programming for KX-NS1000>The trunk adapter is basically SIP provider for KX-NS1000.Following has to be programmed.- IP address of the adapter as SIP server destination - SIP registration User ID (Password is not required.)- Connection Attribute : SIP Provider / Trunk Adapter E1/ ISDN E1 / PRI SIP Extension401-430 30ch or 23ch ID 401-430SIP Trunk KX-NS1000

  19. 33. Concept of Programming - Call <Programming for KX-NS1000 - CONT>Programming of the trunk adapter is not required for DDI / DIL incoming call from E1/PRI to SIP extension. It works like DIL 1:1 without programming and DDInumber and caller ID are informed from the trunk adapter to KX-NS1000.Programming of KX-NS1000 is required for DDI / DIL.Outgoing call is also programmed forKX-NS1000 instead of the trunk adapter. Therefore administrator has to access only KX-NS1000 to change extension number, DDI and so on after dealer installed. E1 / ISDN E1 / PRI CH1 CH2 CH30 Trunk Adapter DDICaller ID SIP Extension 401 402 430 SIP Trunk KX-NS1000

  20. Trunk Adaptor Chapter 4Step by Step Programmingfor Trunk Adapter KX-NS1000

  21. Trunk Adaptor 41. Initialize Operation and “SYSTEM” LED display is as follows.1. Power On (Connect AC adapter or connect LAN with PoE) (a) Amber On (5 sec) (b) Amber rapid flash (5 sec)2. During (b), keep pressing Initialize button for 1s. (c) Off (2 sec) (d) Amber On (30 sec) (e) Amber slow flash (120 sec) (f) Green slow flash- Display of (b) finishes before 5 sec after operation of (2).- Display of (f) means success of initialization and awaiting “Easy set-up” of web maintenance console. KX-NS1000 System LED Initialize Button

  22. Trunk Adaptor 42. LED Indication LED indication is as follows. KX-NS1000

  23. Trunk Adaptor 43. PC Connection - 1 (1) Set IP address 192.168.0.99 for example to your PC like first connection of KX-TDE or KX-NCP. - Trunk adapter does not have maintenance port with DHCP server. - Sub-net mask should be 255.255.255.0 (2) Connect 192.168.0.151 by Firefox. - Default IP address of trunk adapter is 192.168.0.151. KX-NS1000 KX-NS1000 DHCP Server 192.168.0.101by default Trunk Adapter For demo, NS1000 with DHCP server function is useful to assign IP address of PC automatically. 192.168.0.151by default 192.168.0.99for example

  24. Trunk Adaptor 43. PC Connection - 2 (1) In 10 seconds from step in previous page, log-in menu is displayed.(2) Input “INSTALLER” as user and “1234” as password. KX-NS1000

  25. Trunk Adaptor 44. Easy setup - Language selection (1) Select language. KX-NS1000

  26. Trunk Adaptor 44. Easy setup - 1 (1) Select Suffix of KX-NS1000 and area. KX-NS1000 No need to change If Suffix is changed, system restarts again after click [OK].Wait 3 min and connect PC again. (a) Amber slow flash (30 sec)(b) Amber On (10 sec)(c) Amber rapid flash (5 sec)(d) Amber On (30 sec)(e) Amber slow flash (120 sec)(f) Green slow flash

  27. Trunk Adaptor 44. Easy setup - 2 No need to change.- Adapter name is only for reference.- Time is used only for error log. KX-NS1000

  28. Trunk Adaptor 44. Easy setup - 3 (1) Input IP address of trunk adapter in actual customer’s network. Get the IP address from IT manager.*) For demo, default is OK. KX-NS1000

  29. Trunk Adaptor 44. Easy setup - 4 No need to change.- Time is used only for error log. KX-NS1000

  30. Trunk Adaptor 44. Easy setup - 5 (1) Input password as you hope, click [Finish].(2) Wait for 30 seconds. KX-NS1000 If LAN setting is changed, system restarts again after click [OK].Wait 3 min and connect PC again. (a) Amber slow flash (30 sec)(b) Amber On (10 sec)(c) Amber rapid flash (5 sec)(d) Amber On (30 sec)(e) Amber slow flash (120 sec)(f) Green slow flash

  31. Trunk Adaptor 45. Maintenance Console - Top menu If LAN setting is changed, (1) Remove the trunk adapter from LAN(2) Connect it to actual customer’s network.(3) Connect PC to IP address of trunk adapter using Firefox.(4) After log-in, following top menu is displayed.If LAN setting is not changed, following Top menu is displayed. KX-NS1000

  32. Trunk Adaptor 45. Maintenance Console - 1 Software version can be confirmedas follows. KX-NS1000

  33. Trunk Adaptor 45. Maintenance Console - 2 Parameter for PRI can be modified as follows.(Same as “PRI + 2 SLT” card) KX-NS1000

  34. Trunk Adaptor 45. Maintenance Console - 3 IP address of adapter can be changed.(No need to change usually.) KX-NS1000

  35. Trunk Adaptor 45. Maintenance Console - 4 Software can be updated by one step.(Not same as KX-NS1000) - Wait 15 minutes after clicking [Execute]. (Same as KX-NS1000.) KX-NS1000

  36. Trunk Adaptor 45. Maintenance Console - 5 E1/ PRI Card diagnosis is supported. KX-NS1000 Out of service can be assigned.This is required for software update also.

  37. Chapter 5Step by Step Programmingfor KX-NS1000

  38. Trunk Adaptor Trunk Adaptor 51. KX-NS1000 - Out of Service Install virtual SIP trunk card.Out of service is required for port or card beforeprogramming in following pages. KX-NS1000

  39. Trunk Adaptor Trunk Adaptor 52. KX-NS1000 - Connection Attribute Change connection attribute from “SIP provider”to “Trunk Adapter” for each channels or click[Trunk Adapter] button to change max. 30 ch at the same time. Use this. No need to program each ch. KX-NS1000

  40. Trunk Adaptor Trunk Adaptor 53. KX-NS1000 - Trunk Adapter button - 1 Input IP address of trunk adapter and click [Next].- Trunk adapter name is for reference. 192.168.0.151 192.168.0.152 KX-NS1000 Web maintenance console for the trunk adapter is opened. For reference Max. 16 Adapter*) If program manually not using “trunk adapter”, more than 16 adapter can be programmed.

  41. Trunk Adaptor Trunk Adaptor 54. KX-NS1000 - Trunk Adapter button - 2 Select range to connect the trunkadapter instead of SIP provider.Select IP address and click [Finish].If fractional service is used, set “20” for example. Otherwise NS1000 tries making call using 21ch to 30ch of PRI. 192.168.0.151 192.168.0.152 SIPProvider KX-NS1000

  42. Trunk Adaptor Trunk Adaptor 55. KX-NS1000 - Registration to SIP Server Connection attribute were programmed by previous step. Parameters for registration to SIP server (E1/PRI adapter) were also programmed. 192.168.0.151 192.168.0.152 KX-NS1000

  43. Trunk Adaptor Trunk Adaptor 56. KX-NS1000 - CLIP “PBX CLIP” has to be selected as follows to send CLIP on extension for outgoing call. KX-NS1000

  44. Trunk Adaptor 57. KX-NS1000 - In Service Set In Service. - Other programming such as ARS, TRS is basically same as PRI for KX-TDE/NCP.- However it is required to program as next 2 pagesadditionally because I/F with trunk adapter is SIP. E1 / ISDN KX-NS1000 When E1/PRI line of trunk adapter is fault, trunk adapter stops communication with KX-NS1000. Therefore the SIP trunk ch of KX-NS1000 becomes fault.This specification is useful not to use the SIP ch automatically for ARS and so on.

  45. Trunk Adaptor Trunk Adaptor 58. KX-NS1000 - Dialing Plan Dialing plan has to be programmed for outgoing callbecause I/F with trunk adapter is SIP en-block dial.Otherwise extension caller has to wait for 10 secondsto hear ring back tone after dial to E1/PRI trunk adapter. KX-NS1000

  46. Trunk Adaptor 59. KX-NS1000 - DDI Modification DDI first 3 digits has to be removed because I/F with trunk adapter is SIP. ID such as “401” + real DDI number is informed as DDI number from E1/PRI adapter to KX-NS1000. E1 / ISDN DDI 4015101DDI 4025101 DDI 5101 KX-NS1000 Program DDI table. DDI 5101

  47. 60. KX-NS1000 - DDI Destination DDI destination programmed is also required.(Same as PRI+SLT2 card in KX-NS1000 or PRI card through stacking card )

  48. Chapter 6Programming Hint forPrivate Mode (QSIG)

  49. Trunk Adaptor 61. Easy Setup for Adapter “Private” has to be selected by easy setup mode. 192.168.0.101 KX-NS1000 192.168.0.151 Ext 2xx H.323 ISDN QSIG Ext 1xx

  50. Trunk Adaptor 62. PRI QSIG mode for Adapter QSIG (Slave) is assigned automatically after easy setup. 192.168.0.101 KX-NS1000 192.168.0.151 Ext 2xx H.323 ISDN QSIG Ext 1xx