HVACR318 – Refrigeration II. Domestic Refrigerators. Refrigeration - Overview. Heat enters the refrigerator by conduction, convection and the introduction of warm food. Warm food in the box raises the temperature. Air in the box is circulated over the cold coil.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'HVACR318 – Refrigeration II' - rhoda


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
hvacr318 refrigeration ii

HVACR318 – Refrigeration II

Domestic Refrigerators

refrigeration overview
Refrigeration - Overview
  • Heat enters the refrigerator by conduction, convection and the introduction of warm food.
  • Warm food in the box raises the temperature.
  • Air in the box is circulated over the cold coil.
  • The air in the box transfers sensible and latent heat to the cold refrigeration coil.
  • The evaporator dehumidifies the air, causing frost to accumulate on the coil surface.
slide4

Freezer Compartment

Freezer Compartment of Refrigerator

slide5

Refrigerator Compartment

Refrigerator/Freezer

Freezer Compartment

slide6

Refrigerator Diagram

The load on the system increases as warm product is added to the box

slide7

Refrigerator Diagram – Heat in Box

Heat is also introduced to the box when the door is opened, and through gaskets that seal the box.

Heat infiltration increases the temperature of the air in the box.

natural draft evaporators
Natural Draft Evaporators
  • Normally of the stamped plate variety
  • Product in the frozen food compartment may be in direct contact with the evaporator.
  • Evaporators can have manual or automatic defrost.
  • Most evaporators have an accumulator at the outlet.
  • Evaporators are not equipped with air filters.
slide9

Stamped-plate Evaporator

Suction Line

Capillary Tube

Freezer compartment

Product in contact with the evaporator coil

evaporator defrost
Evaporator Defrost
  • Manual Defrost
    • Unit must be turned off and emptied
    • Room heat, a pan of water or small heater is used to melt accumulated frost
    • Never use sharp objects to remove frost
  • Automatic Defrost
    • Accomplished with internal or external heat
    • Hot gas or electric heating elements
slide11

How NOT to Remove Frost on Coil

Frost on Coil

NEVER USE SHARP OBJECTS TO REMOVE ICE FROM THE COIL

the compressor
The Compressor
  • Pumps heat-laden, vapor refrigerant from the evaporator to the condenser.
  • Usually of the hermetically sealed, reciprocating or rotary variety, ranging from 1/10 to 1/3 horsepower.
  • They are located at the bottom of the unit
  • They can have oil cooler lines.
  • Refrigerant lines connected to the compressor are often made of steel or copper
the condenser
The Condenser
  • Air-cooled variety
  • Can be of the natural or forced draft variety
  • Natural draft condensers
    • Located at the back of the unit
    • Must have proper airflow across it
  • Forced draft condensers
    • Usually located under the unit at the back
    • Must have a set air pattern
slide14

Back View of Domestic Refrigerator

BACK OF REFRIGERATOR

Natural-draft condenser

Compressor

Suction line

defrost condensate
Defrost Condensate
  • Domestic refrigerators are low-temperature appliances.
  • Frost will accumulate on the evaporator coil; the coil must be defrosted.
  • The compressor and condenser help to evaporate the water that accumulates during defrost.
  • Defrost water pan should be periodically cleaned.
slide16

Condenser Coil Diagram

Condenser Coil

Condensate Line

Condensate Pan

Discharge line run to bottom of condensate pan

compressor oil coolers
Compressor Oil Coolers
  • Helps keep compressor oil cool.
  • Line leaves the compressor and makes several passes through the condenser.
  • The line then returns to the compressor.
  • Air passes over the line just as air passes over the coils of the condenser coil.
  • Oil cooler lines are closed loops.
slide18

Compressor Oil Cooler Diagram

BACK OF REFRIGERATOR

Oil Cooler Line

Chimney-type condenser

Compressor

Suction line

metering device
Metering Device
  • Domestic refrigerators use capillary tubes.
  • Capillary tube is usually fastened to the suction line for increased heat exchange rate.
  • Capillary tube can also be run inside the suction line.
  • Refrigerant flow through the capillary tube is determined by the length of the tube, the bore size and the pressure difference across the tube.
  • Designed for indoor operation.
slide20

Capillary Tube

Capillary Tube Diagram

Suction Line

Capillary tube connected to the suction line

Capillary tube run inside the suction line

slide21

Capillary Tube Cross Section

Capillary Tube

Suction Line

High Temperature, High Pressure Refrigerant

Heat is transferred from the refrigerant in the capillary tube to the refrigerant in the suction line

Suction Gas

the domestic refrigerated box
The Domestic Refrigerated Box
  • Modern refrigerators have magnetic gasket material around the door for a better seal.
  • Condensate flows from the box, through a trap to the condensate pan.
  • The trap prevents air from entering the box.
  • Different compartments can be maintained at different temperatures.
  • Some units are equipped with ice and water dispensers.
wiring and controls
Wiring and Controls
  • Wiring diagrams permanently attached to the unit.
  • Diagrams can be of the pictorial or line variety.
  • Components controlled in a domestic refrigerator:
    • Compressor
    • Fan motors
    • Heaters
    • Lights
    • Ice Maker
    • Defrost Components
slide24

Wiring Diagram Sample

Water Valve Solenoid

Ice Maker

Lamp

Mullion Heater

Energy Saver

Thermostat

Defrost Timer

M

Defrost Heater

Evaporator Fan Motor

M

C

S

Overload

Line Cord

Compressor

R

Relay

compressor controls
Compressor Controls
  • Compressor is controlled by a line-voltage thermostat.
  • The thermostat:
    • Closes on a rise in box temperature.
    • Passes power to the compressor when closed.
    • Has a remote bulb and is field adjustable.
    • Does not have a numerical temperature scale.
    • Remote bulb contains a volatile fluid that pushes against the diaphragm in the thermostat.
compressor start circuit
Compressor Start Circuit
  • Designed to help the compressor start.
  • The starting components give the compressor additional starting torque.
  • Circuit often consists of a relay and a start capacitor.
  • Some units use a positive temperature coefficient.
    • Known as the PTC
    • Resistance varies with temperature.
    • As the temperature increases, so does the resistance.
slide27

Compressor Start Circuitry

Current Relay

Overload

Coil

Run Terminal

Thermostat

Compressor

Contacts

Start Terminal

Common Terminal

sweat prevention heaters
Sweat Prevention Heaters
  • Designed to keep the refrigerator cabinet above the dew point temperature.
  • Cabinets will sweat more when the humidity level is high.
  • Small wire heaters are mounted within the cabinet walls.
  • Some units have manual switches to turn the heaters on and off.
refrigerator fan motors
Refrigerator Fan Motors
  • Evaporator fan motor:
    • Connected to small squirrel-cage blowers
    • Runs continuously, except when the unit is in defrost
    • Usually an open-type motor
  • Condenser fan motor:
    • Connected to a propeller-type fan
    • Usually a shaded pole motor
    • Located under the refrigerator at the back of the unit
ice maker operation
Ice Maker Operation
  • Located in the low temperature compartment.
  • Water flow to the ice maker is solenoid controlled.
  • Water flows to fill the ice maker tray.
  • A timer gives the water ample time to freeze.
  • The ice is then harvested by either twisting the tray or by heating the tray to free the ice.
  • Ice-making sequence is often time controlled.
gauge connections
Gauge Connections
  • Domestic appliances not equipped with service ports.
  • Installing gauges is not always necessary.
  • When to install gauges:
    • When there is a leak
    • When repairing the refrigerant circuit
    • As a last resort
  • Use process tubes for taking pressure readings.
  • Process tubes can be pinched off.
low refrigerant charge
Low Refrigerant Charge
  • If there is a low refrigerant charge, there is a leak.
  • Leak should be located and repaired
  • One method to determine if the charge is correct
    • Turn unit off for about five minutes.
    • Turn unit on while touching the outlet of the evaporator.
    • If the line gets cold for a short period of time, the charge is most likely correct.
    • If a low charge is suspected, gauges can be installed.
refrigerant overcharge
Refrigerant Overcharge
  • Forced-draft condensers are more efficient than natural-draft condensers.
  • Systems with forced-draft condensers operate with lower head pressures.
  • The head and suction pressures of the unit will be higher during a hot pull down (excessive load).
  • If the compressor sweats around the suction line, there is most likely an overcharge.
refrigerant leaks
Refrigerant Leaks
  • Domestic refrigerators only hold a few ounces of refrigerant, so even a small leak will prevent the unit from operating effectively.
  • Leaks are best found in the shop; small leaks are difficult to locate in the home.
  • Very small leaks are found with high quality leak detectors
evaporator leaks
Evaporator Leaks
  • Aluminum evaporator leaks are repaired with epoxy; soldering aluminum evaporators is not practical.
  • Always follow the manufacturer’s instructions before attempting to make epoxy repairs.
  • The area around the leak should be cleaned well before attempting to make a repair.
evaporator leaks1
Evaporator Leaks
  • Pulling a slight vacuum in the system while making an epoxy repair can help pull a small amount of epoxy into the leak, creating a stronger bond.
condenser leaks
Condenser Leaks
  • Refrigerator condensers are often made of steel.
  • Leaks usually occur at the ends of the coil where the coil connections are made to the rest of the system.
  • While operating, units lose refrigerant faster through high side leaks than low side leaks.
  • Solders with a high silver content are best for repairing leaks in steel tubing.
refrigerant piping leaks
Refrigerant Piping Leaks
  • Interconnecting piping leaks can be very difficult to repair.
  • The evaporator may have to be removed.
  • It is often more economical to replace the entire unit.
  • Leaks within fiberglass walls are often caused by electrolysis.
refrigerant piping leaks1
Refrigerant Piping Leaks
  • Flare unions can be used on aluminum/copper joints
  • If one leak is found, there are likely others.
compressor changeout
Compressor Changeout
  • Use an exact replacement whenever possible.
  • Identify all tubing connections before removing the old compressor from the unit.
  • The refrigerant should be recovered from the unit.
compressor changeout1
Compressor Changeout
  • Remove piping connections from the compressor using a tubing cutter or torch.
  • Clean all tubing ends and compressor stubs.
  • Add process tubes and a liquid line filter drier.
system evacuation
System Evacuation
  • Evacuate system after leak checking and repairing.
  • Removing Schrader pins (stems) and valve depressors will speed the evacuation process.
  • Moisture may be trapped under the compressor oil.
  • Use full size gauge connections on high and low sides.
system evacuation1
System Evacuation
  • Allow vacuum pump to operate for about 8 hours.
  • Perform a triple evacuation whenever possible.
  • Minimum vacuum should be about 500 microns.
capillary tube repair
Capillary Tube Repair
  • Capillary tubes can develop leaks when they rub against another surface.
  • Capillary tubes are delicate and must be handled carefully.
  • Capillary tubes should be cut with a file.
  • Care should be taken to protect the bore.
  • Capillary tube sections can be joined with a section of larger tubing.
capillary tube repair1
Capillary Tube Repair
  • Use as little filler material as possible when brazing.
  • Capillary tubes can be replaced if necessary.
slide46

Leak Repair, Step 1

Leak in the Capillary tube

Use a file to cut through the capillary tube on both sides of the leak point. Be sure not to cut all the way through to the bore of the tubing!

slide47

Leak Repair, Step 2

Repeat the process on the underside of the capillary tube.

slide48

Leak Repair, Step 3

Gently bend the tubing to break off the damaged section of tubing.

Damaged section of tubing

slide49

Leak Repair, Step 4

Insert the ends of the capillary tube to be joined into a small section of larger tubing

slide50

Leak Repair, Step 5

Crimp the larger tubing around the two ends of the capillary tube, making certain that the ends of the capillary tubes are not damaged.

slide51

Leak Repair, Step 6

When brazing, use as little filler material as possible!

Pinched portion of copper tubing

Make certain that the ends of the capillary tubes do not touch!

compressor capacity check
Compressor Capacity Check
  • Before condemning the compressor, check:
    • The door gaskets.
    • Excessive load on the box.
    • Leaking hot gas solenoid (defrost).
    • Improper condenser airflow.
  • Use manufacturer’s guidelines when evaluating the compressor.
  • Determine compressor amperage.
summary 1
Summary 1
  • Heat enters the refrigerator by conduction, convection and the introduction of warm food.
  • Warm food in the box raises the box temperature and the evaporator saturation temperature and pressure.
  • Evaporators can be natural or mechanical draft.
  • Evaporators can be either automatic or manual defrost.
  • Natural draft evaporators are defrosted manually.
summary 2
Summary 2
  • Compressors are often equipped with oil cooler lines.
  • Condensers are air cooled and can be natural or mechanical draft devices.
  • The metering device used on domestic refrigerators is the capillary tube.
  • Different compartments in the refrigerator can be maintained at different temperatures and humidities.
summary 3
Summary 3
  • The electrical components controlled in a domestic refrigerator are the compressor, fan motors, lights, ice makers, heaters and defrost components.
  • The compressor thermostat closes on a drop in box temperature.
  • The compressor uses starting components to increase the starting torque of the compressor motor.
  • Gauges should be installed on process tubes and only when absolutely necessary.
summary 4
Summary 4
  • If there is a low refrigerant charge, there is a leak
  • Evaporator leaks can be repaired with epoxy.
  • Condenser leaks are often repaired with high silver content brazing filler materials.
  • Capillary tubes can be repaired or replaced.
  • Care must be taken to not block the bore of the capillary tube during the repair process.