NATIONAL FIRE CODE REQUIREMENTS. Presented by : Rick Gratton. Section 5.6. CONSTRUCTION AND DEMOLITION SITES. Fire Code Relevant Sections. PROTECTION OF ADJACENT BUILDING 5.6.1.2 FIRE SAFETY PLAN FOR EACH SITE 5.6.1.3 ACCESS FOR FIREFIGHTING 5.6.1.4

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'NATIONAL FIRE CODE REQUIREMENTS' - raheem


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
National fire code requirements

NATIONAL FIRE CODE REQUIREMENTS

Presented by :

Rick Gratton


Section 5 6
Section 5.6

  • CONSTRUCTION AND DEMOLITION SITES


Fire code relevant sections
Fire Code Relevant Sections

  • PROTECTION OF ADJACENT BUILDING 5.6.1.2

  • FIRE SAFETY PLAN FOR EACH SITE 5.6.1.3

  • ACCESS FOR FIREFIGHTING 5.6.1.4

  • FIRE EXTINGUISHER ON SITE 5.6.1.5

  • HOT WORKS 5.6.1.7

  • SAFE EGRESS 5.6.1.8

  • DISPOSAL OF COMBUSTIBLE REFUSE 5.6.1.19


5 6 1 2
5.6.1.2

  • PROTECTION OF ADJACENT BUILDING

  • 1) Protection shall be provided for exposed adjacent buildings and facilities that would be exposed to fire originating from buildings, parts of buildings, facilities and associated areas undergoing construction, alteration or demolition operations.



Nfc appendix notes
NFC Appendix Notes adjacent buildings or facilities will be exposed to an unacceptable risk of damage due to fire

NFC Appendix A5.6.1.2

  • Methods or materials used to protect adjacent buildings include:

  • Gypsum Sheathing

  • Spatial Separation

  • Water Curtains

  • Temporary fire barrier such as fire tarpaulin


Current issues with 5 6 1 2
CURRENT ISSUES WITH 5.6.1.2 adjacent buildings or facilities will be exposed to an unacceptable risk of damage due to fire

  • No defined distance to adjacent buildings

  • Definition of “undergoing construction”

  • Enforcement

  • Protection required on inside or outside of coated sheathing?


Building code requirements
BUILDING CODE REQUIREMENTS adjacent buildings or facilities will be exposed to an unacceptable risk of damage due to fire


Fire code requirements examples of compliance
FIRE CODE REQUIREMENTS (EXAMPLES OF COMPLIANCE) adjacent buildings or facilities will be exposed to an unacceptable risk of damage due to fire


9 25 condensation control
9.25 Condensation Control adjacent buildings or facilities will be exposed to an unacceptable risk of damage due to fire

  • Sheet and panel-type materials must have a water vapor permeance less than 60 ng when incorporating into a building assembly required to be insulated

  • Gypsum sheathing - 1373

  • OSB - 44 but allowed as a wood based sheathing not more than 12.5 mm thick

  • Coatings must not affect the ability of such sheathings to dry


Questions
QUESTIONS? adjacent buildings or facilities will be exposed to an unacceptable risk of damage due to fire