Modelling of Atomic Force Microscope(AFM)

Modelling of Atomic Force Microscope(AFM). Deng Wenqi Supervisors: Guang -Ming Zhang,Dave Harvey, Francis Lilley. Outline. Background of AFM Brief introduction of Comsol Multiphysics Simulation and results Project plan. How AFM works?.

plato-moore
Download Presentation

Modelling of Atomic Force Microscope(AFM)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Modelling of Atomic Force Microscope(AFM) Deng Wenqi Supervisors: Guang-Ming Zhang,Dave Harvey, Francis Lilley

  2. Outline • Background of AFM • Brief introduction of ComsolMultiphysics • Simulation and results • Project plan

  3. How AFM works? • The x and y-piezos provide lateral scanning(~30nm) , while the z-piezo extends and retracts to follow the surface topography(up to 0.1nm) .

  4. Image mode • Non-contact mode • The cantilever is oscillated near its resonant frequency at a position just above the sample surface • Measures the topography by detecting the vibration amplitude affected by the attractive forces • Difficult to use in normal ambient conditions • Better to use in ultra high vacuum conditions

  5. Image mode • Contact mode • Constant force during scanning • Damage soft sample

  6. Image mode • Tapping mode • The cantilever is vibrated at its resonant frequency • Intermittent contact with sample • Reduce sample destruction

  7. Phase imaging • Measure the phase lag of the cantilever oscillation (solid wave) relative to the phase of the piezo drive (dashed wave). • The amplitude signal is used simultaneously by the controller for Tapping Mode feedback. • Spatial variations in sample properties cause shifts in the cantilever phase (bottom)

  8. Why phase image provides more information of structure? Topography (left) & phase (right) images of a composite polymer • Higher spots in the AFM topography images should correspond to the hard phase polymer? • Brighter areas correspond to harder materials? • We don’t have an agreement yet.

  9. First model • Model consists of a piezo actuator, a cantilever and the tip. • A sinusoidal voltage signal is applied to piezo( purple block)

  10. Free vibration results • Vibration curve is not smooth

  11. Contact model • Define contact pair between the tip and sample • Omit the inertial effect • Start with linear discretization model

  12. Displacement and contact force curves • Bouncing effect

  13. Quasi-static study • Bouncing effect disappear • Smooth curves • Free vibration

  14. Quasi-static study • Different materials such as cooper,GaAs,Ge,Si,andpolymer are tested Contact force curve of cooper

  15. Phase curve Phase shift Phase shift Light contact Deeper contact Young’s modulus Young’s modulus

  16. Phase curve Phase shift Phase shift Tip sample separation(Polymer) Tip sample separation(Copper)

  17. Problems of static study • It omits the inertial effect of the whole model • Does not reflect the resonant frequency of the cantilever • No matter what frequency you apply, the amplitude is almost the same.

  18. Problem of resonant frequency • When using linear discretization model, the resonant frequency is not right. • Different mesh lead to different results 2.69e5 Hz 1.15e5 Hz

  19. This problem will not occur when changing to quadratic discretization. 82424.8 Hz 82425 Hz

  20. New model AFM Probe Type: PNP-DB Manufacturer: NanoWorld Geometry built in COMSOL

  21. Eigenfrequency Study Resonant frequency is 82424Hz

  22. Time dependent study 1 Fixed boundary Edge load=sin(2*pi*f*t)*100[nN] Mesh Free vibration

  23. Time dependent study 2 • Apply the contact force on the tip • 1.Treat the contact force as spring • 2.Relate the contact force with Young’s modulus of tip and sample Displacement curves of the cantilever • Phase shift between green and blue is 3.8 degree • Phase shift between red and blue is is 4 degree

  24. Time dependent study 2 • Load a force on the sample for a short period • Unload the force, sample almost recovered

  25. Problems of simulation • Difficult to define the contact force equation • It’s better to model tip and sample together • However, it is still difficult to solve contact modelling in time dependent study. Contact model

  26. Project Plan Aim: 1) Phase interpretation 2) Nano-NDE(non-destructive evaluation) for defect detection, imaging of internal micro-structures, measurement of mechanical properties. Test samples: 1) Single layer samples with surface defects. 2) Multiple layers samples with defects

  27. Project Plan Methodologies • Elastic deformation force only • Elastic deformation force + Van Der Waals • Curve of phase shift vs height • Curve of phase shift vs material • Image restoration using these curves: material phase image

  28. Project Plan Future work • Solve the problem of contact modelling • Define the relationship between phase shift and material parameter, such as phase shift vs young’s modulus, phase shift vs thickness • Observe how phase change in non-destructive evaluation, eg. The sample has a defect inside • Test soft material like cells and compare the results with real experiment