1 / 72

Chapter 5

Chapter 5. Impedance Matching and Tuning. Why need Impedance Matching. Maximum power is delivered and power loss is minimum. Impedance matching sensitive receiver components improves the signal-to-noise ratio of the system.

perry
Download Presentation

Chapter 5

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 5 Impedance Matching and Tuning

  2. Why need Impedance Matching • Maximum power is delivered and power loss is minimum. • Impedance matching sensitive receiver components improves the signal-to-noise ratio of the system. • Impedance matching in a power distribution network will reduce amplitude and phase errors. • Basic Idea The matching network is ideally lossless and is placed between a load and a transmission line, to avoid unnecessary loss of power, and is usually designed so that the impedance seen looking into the matching network is Z0. ( Multiple reflections will exist between the matching network and the load) • The matching procedure is also referred to as “tuning”.

  3. Design Considerations of Matching Network • As long as the load impedance has non-zero real part (i.e. Lossy term), a matching network can always be found. • Factors for selecting a matching network: 1) Complexity: a simpler matching network is more preferable because it is cheaper, more reliable, and less lossy. 2) Bandwidth: any type of matching network can ideally give a perfect match at a single frequency. However, some complicated design can provide matching over a range of frequencies. 3) Implementation: one type of matching network may be preferable compared to other methods. 4) Adjustability: adjustment may be required to match a variable load impedance.

  4. Lumped Elements Matching • L-Shape (Two-Element) Matching • Case 1: ZL inside the 1+jx circle (RL>Z0) • Use impedance identity method

  5. Example5.1: Design an L-section matching network to match a series RC load with an impedance ZL= 200-j100, to a 100 line, at a frequency of 500 MHz? Solution ( Use Smith chart) 1. Because the normalized load impedance ZL= 2-j1 inside the 1+jx circle, so case 1 network is select. 2. jB close to ZL, so ZL YL. 3. Move YL to 1+jx admittance circle, jB=j 0.3, where YL 0.4+j 0.5. 4. Then YLZL, ZL 1+j 1.2. So jX=j 1.2. 5. Impedance identity method derives jB=j 0.29 and jX=j 1.22.  6. Solution 2 uses jB=-j 0.7, where YL 0.4-j 0.5. 7. Then YLZL, ZL 1-j 1.2. So jX=-j 1.2. 8. Impedance identity method derives jB=-j 0.69 and jX=-j 1.22.

  6. -0.7

  7. Use resonator method (Case 1: RS<1/GL) Goal: Zin=Rs =S11=(Zin-Rs)/(Zin+Rs)=0

  8. Case 2: ZL outside the 1+jx circle (RL<Z0) • Use admittance identity method

  9. Use resonator method (Case 2: RS>RL) Goal: Yin=1/Rs =S11= =0

  10. Matching Bandwidth Series-to-Parallel Transformation

  11. Case 1: ZL inside the 1+jx circle (RL>Z0)

  12. Define QL and Qin for RLC resonator

  13. Similarly, for case 2: ZL inside the 1+jx circle (RL>Z0). Summary

  14. Example5.2: Design an L-section matching network to match load impedance RL= 2000, to a RS= 50, at a frequency of 100 MHz? Solution Because RS <1/ GL, so case 1 network is select. 

  15. =S11 =S22 BW=34%

  16. Three Elements Matching (High-Q Matching) • Use resonator method for complex load impedance. • Splitting into two “L-shape” matching networks. • Case A: - shape matching • Case B: T- shape matching Goal: Zin(=0)=RS ,(=0)=0 Goal: Zin(=0)=RS ,(=0)=0

  17. Case A: - shape matching Conditions: RV<1/GL , RV<RS P.S. RV : Virtual resistance

  18. Case B: T- shape matching Conditions: RV>RL ,RV>RS P.S. RV : Virtual resistance

  19. Example5.3: Design a three elements matching network to match load impedance RL= 2000, to a RS= 50, at a frequency of 100 MHz, and to have BW<5%? Solution Case A: - shape matching

  20. Splitting into two “L-shape” matching networks

  21. Four solutions for -shape matching networks

  22. BW=4%

  23. Case B: T- shape matching

  24. Splitting into two “L-shape” matching networks

  25. Four solutions for T-shape matching networks

  26. BW=4%

  27. Cascaded L-Shape Matching (Low-Q Matching) • Use resonator method for complex load impedance. • Splitting into two “L-shape” matching networks. • Low Q value but large bandwidth. • Case A: • Case B: Conditions: RL<RV<RS Goal: Zin(=0)=RS ,(=0)=0 Conditions: 1/GL>RV>RS Goal: Zin(=0)=RS ,(=0)=0 P.S. RV : Virtual resistance

  28. Splitting into two “L-shape” matching networks for case A

  29. Splitting into two “L-shape” matching networks for case B

  30. Example5.4: Design a cascaded L-shape matching network to match load impedance RL= 2000, to a RS= 50, at a frequency of 100 MHz, and to have BW60%? Solution Select 1/GL>RV>RS Splitting into two “L-shape” matching networks

  31. Four solutions for Cascaded L-shape matching networks

  32. BW=61%

  33. Multiple L-Shape Matching • Lower Q value but larger bandwidth follows the number of L-section increased. • Conclusions: • Lossless matching networks consist of inductances and capacitances but not resistances to avoid power loss. • Four kinds of matching techniques including L-shape, -shape, T-shape, and cascaded L-shape networks can be adopted. Generally larger Q value will lead to lower bandwidth. • A large range of frequencies (> 1GHz) and circuit size may not be realizable.

  34. Transmission-Line Elements Matching • Single-Stub Matching • Easy fabrication in microstrip or stripline form, where open-circuit stub is preferable. While short-circuit stub is preferable for coax or waveguide. • Lumped elements are not required. • Two adjustable parameters are the distance d and the value of susceptance or reactance provided by the shunt or series stub. • Shunt Stub • Series Stub

  35. Example5.5: Design two single-stub (short circuit) shunt tuning networks to match this load ZL= 60-j 80 to a 50 line, at a frequency of 2 GHz? Solution 1. The normalized load impedance ZL= 1.2-j1.6. 2. SWR circle intersects the 1+jb circle at both points y1 = 1.0+j1.47 y2 = 1.0-j1.47. Reading WTG can obtain: d1= 0.176-0.065=0.11 d2= 0.325-0.065=0.26. 3. The stub length for tuning y1 to 1 requires l1 = 0.095, and for tuning y1 to 1 needs l2 = 0.405.

  36. 1. ZL= 60-j 80 at 2 GHz can find R= 60,C=0.995pF. 2. Solution 1 is better than solution 2; this is because both d1 and l1 are shorter for solution, which reduces the frequency variation of the match.

  37. Analytic Solution for Shunt Stub

  38. Problem 1: Repeat example 5.5 using analytic solution.

  39. Example5.6: Design two single-stub (open circuit) series tuning networks to match this load ZL= 100+j 80 to a 50 line, at a frequency of 2 GHz? Solution 1. The normalized load impedance ZL= 2-j1.6. 2. SWR circle intersects the 1+jx circle at both points z1 = 1.0-j1.33 z2 = 1.0+j1.33. Reading WTG can obtain: d1= 0.328-0.208=0.12 d2= 0.672-0.208=0.463. 3. The stub length for tuning z1 to 1 requires l1 = 0.397, and for tuning z1 to 1 needs l2 = 0.103.

  40. 1. ZL= 100+j 80 at 2 GHz can find R= 100,L=6.37nH.

  41. Analytic Solution for Series Stub

  42. Problem 2: Repeat example 5.6 using analytic solution.

  43. Double-Stub Matching adjustable tuning • Variable length of length d between load and stub to have adjustable tuning between load and the first stub. • Shunt stubs are easier to implement in practice than series stubs. • In practice, stub spacing is chosen as /8 or 3/8 and far away 0 or /2 to reduce frequency sensitive. • Original circuit • Equivalent circuit

  44. Disadvantage is the double-stub tuner cannot match all load impedances. The shaded region forms a forbidden range of load admittances. • Two possible solutions b1,b2 and b1’,b2’ with the same distance d.

  45. Example5.7: Design a double-stub (open circuit) shunt tuning networks to match this load ZL= 60-j 80 to a 50 line, at a frequency of 2 GHz? Solution 1. The normalized load impedance YL= 0.3+j0.4 (ZL= 1.2-j1.6). 2. Rotating /8 toward the load (WTL) to construct 1+jb circle can find two values of first stub b1 = 1.314 b’1 = -0.114. 3. Rotating /8 toward the generator (WTG) can obtain y2= 1-j3.38 y’2= 1+j1.38.

  46. 4. The susceptance of the second stubs should be b2 = 3.38 b’2 = -1.38. 5. The lengyh of the open-circuited stubs are found as l1 = 0.146, l2 = 0.482, or l1 = 0.204, l2 = 0.350. 6.ZL= 60-j 80 at 2 GHz can find R= 60, C=0.995pF.

More Related