Many States and Local Utilities Offer Additional Rebates

Many States and Local Utilities Offer Additional Rebates Visit www.dsireusa.org/incentives to Find Rebates in Your Area. Giannoni Stainless Steel Heat Exchanger Mono Block. Top Vent Outlet for Simplified Vent Connection. At the Heart of All

orde
Download Presentation

Many States and Local Utilities Offer Additional Rebates

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Many States and Local Utilities Offer Additional Rebates Visit www.dsireusa.org/incentives to Find Rebates in Your Area.

  2. Giannoni Stainless Steel Heat ExchangerMono Block Top Vent Outlet for Simplified Vent Connection At the Heart of All PureFire Heat Exchangers - the Stainless Steel Loop – Highly Resistant to Corrosion Bottom-Up Burner Connection Helps Keep Flue Gasses from Backing out at Shut-Down

  3. Giannoni Stainless Steel Heat ExchangerMono Block Boiler Supply (Out) Boiler Return (In) Supply Sensor Return Sensor Baffle in Manifold to Separate Supply & Return Water Separate Condensate Drain Connections for Heat Exchanger & Vent Connectors Drain/Purge Valve (Supplied)

  4. Removable Front Plastic Cover - Removable Metal Side PanelsWell-Sealed Cabinet - Prevents Combustion Odors which Promotes Healthy Indoor AirTop Connections – Fuel, Piping Wiring & Venting Sleek & Functional Mono Design Vent & Air Connections System Return (In) Display Service Switch System Supply (Out) Fuel Gas Connection Main Control Blower & Gas Valve Front Cover Left Side Panel Condensate System

  5. Duo Block DesignStainless Steel Heat Exchanger Top Vent Outlet Connection Bottom-Up Burner Mounting Helps Keep Flue Gasses from Backing out at Shut-Down Duo Design Allows Smaller Boiler Footprint

  6. Mono Block Design:4 Inputs: 50, 80, 110 & 1402 Cabinet Sizes PureFire 110 & 140 PureFire 50 & 80

  7. Duo Design Concept Cooled Exhaust Gas Outlet Cooled Exhaust Gas Outlet Condensate Deflector in Upper Chamber Eliminates the Need For 2nd Connection on Condensate Collector, which is Sealed with a Cap Before Second Exchange Condensate Deflector After Second Exchange Manifold with Return Inlet &Supply Outlet Return Water Manifold Between Exchangers Condensate Drip Supply Water Burner Target Wall After First Exchange Condensate Drain Condensate Drain Cooled Flue Gas After First Exchange Hot Flue Gas from Burner Cooled Flue Gas After Second Exchange

  8. Removable Metal Side Panels & Improved Cabinet SealsTop Connections for Fuel, Venting & Wiring – 8 KnockoutsLower Left Side Brass Piping Connections New Duo PureFire Design Features

  9. Duo Heat Exchanger Tappings Flue Gas Sensor (Other Side) Vent Pressure Switch (Front Side) Return Sensor Relief Valve Baffle in Manifold to Separate Supply & Return Water ⅝” Condensate Connection Supply Sensor Boiler Return (In) Boiler Supply (Out) Drain/Purge Valve (Inside)

  10. Duo Block Design - Inputs: 210 & 399mbh 2 Cabinet Sizes

  11. PureFire 210 & 399 Ratings • 5:1 Turndown Ratio • Can Be Higher When Approval Agencies Raise Maximum • Higher Turndown with Large Inputs Are More Reliable & Have a Greater Impact on Efficiency • Vent Length As Much As 200’ Total Equivalent • Circulators PF-210 – Taco 0014 or Grundfos UPS 26-99FC PF-399 – Taco1400-20 or Grundfos UP 32-80F

  12. Full-Featured & Easy-To-Use Boiler Control with Plain English Text Display No Need to Memorize CodesMost Features are Pre-Programmed & Ready-to-go

  13. New Features Scheduled for Release withPF-210 & PF-399 in 2009 Display Main Control Same Location for Display As Mono Block Design New Location for Main Control for Easy Access

  14. All PureFire Boiler Controls Use Fuse Protection- Easily Replaceable Fuse - Main Control Fuse Size = 5mm x 20mm, 250 Volt, Slow Blow Available at Radio Shack (Part# 270-1067) 4-Pack - $2.99

  15. Molded Plastic JacketWith Tinted Clear Lens for Viewing Control Display

  16. EBM-Papst Blowers Dungs Gas Valves Extensively Field-Tested by PeerlessPatented Whirlwind Technology Promotes Better Fuel/Air Mixing for Better Combustion Various Swirl Plates for Different Boiler Sizes

  17. Dungs Gas Valve Operation • Adjust CO2 ONLY with Throttle Screw • Gas valves are preset at factory for fuel type • Fuel Pressure can be measured at Inlet Pressure Tap

  18. Worgas Metal Mesh BurnersProvide Stable and Reliable Flame Igniters & Flame SensorsProvide Dual Sensing of Burner Flame – Help Prevent Unnecessary Lockouts

  19. Molded Plastic Vessels for Condensate Collection & Neutralizing Optional for PF-210 & 399

  20. Simplified Electrical ConnectionsPre-Wired Harnesses & Split Terminal Strips

  21. Additional Features Leveling Legs Courtesy Outlet

  22. Features Outdoor SensorFor Outdoor Reset (Supplied as Standard Equipment) Knock-out GrommetFor Low-Voltage WiresHelps Protect Wires &Keep Cabinet Sealed

  23. Venting Options: PVC, CPVC & PP (M&G)with Stainless Steel, Concentric PVC & PP Termination Options

  24. Control DisplaySample Screens

  25. Control DisplaySample Screens

  26. Control Features New or Enhanced in 2009

  27. New Control Features Cascade Firing of Multiple Boilers • Control up to16 Boilers in One System • No Extra Controls Required, Only 1 System Sensor • Automatic Rotation of Boilers (Lead/Lag) • No Extensive Programming Required - Most Options Are Pre-Selected, But Adjustable • Boilers will be Fired Proportionally with Timed Start and Stop for Maximum Efficiency & Longevity • All PureFire™ Boilers will be Cascade Capable - After the Release of the new PF-210 & PF-399 - Existing PF Boilers Can Be Easily Upgraded • New Controls will be Compatible with Older Displays & Vice Versa

  28. Cascade Functions with Multiple Boilers • The Control on Any Boiler can be the Master Control • Simple Instructions Explain How to Designate the Master Control and All Dependent Controls • All Sensors and Non-Boiler Pumps are Wired to the Master • Control & Status of All Boilers Including Resets can be Done Through Master • Each Dependent Boiler Controls Only Its Own Pump • Boiler Controls are Interconnected in Parallel with only 1 Set of Thermostat Wires Between Each Boiler • Future PC Connections can be made to Any Dependent Control

  29. Control Features Safety & Efficiency

  30. Control Features Central Heating

  31. Outdoor Reset

  32. Central Heating Mode Choices

  33. Control Features Domestic Hot Water

  34. DHW Mode Choices

  35. Pump Mode Choices

  36. Typical Cast Iron Boiler PipingParallel Piping Conversion to Primary/Secondary

  37. Primary/Secondary PipingDHW Piped into Primary Loop Zone Relay X X

  38. Primary/Secondary PipingDHW Piped into Boiler Loop Zone Relay X X

  39. Low Voltage Wiring

  40. Line Voltage Wiring

  41. Wiring for PF-210 & PF-399

  42. Line Voltage Wiring – High Amp Circ Pumps • PureFire main control has a max amp draw of 5 amps including gas valve & other internal loads. • Total amp draw of all operating Circulators must be less than about 4.5 amps. • For example the General Circulator + the CH Circulator or the DHW circulator must be less than 4.5 amps. • If the circulator amp draw is higher than 4.5 amps, it must be isolated using a relay. • A RIB2401B relay may be used for circulator motors up to 1 horsepower. • The wiring schematic below shows how to wire isolation relays to the circulators.

  43. Accessories System Pipe SensorTo Aid in System Mixing For Multiple Boiler Systems DHW SensorFor Optional Control of Indirect Water Heater - Control Tank Temp From Boiler

  44. Accessories Stainless Steel TableAdjustable Legs Wall Mounting Bracket Now Included with BoilerFor All Four Sizes:50, 80, 110, 140

  45. Simple Fuel Conversion - LP & NG • Conversion Kit Included with Every Boiler • No Orifices to Install or Remove • Spelled Out in the Conversion Kit: • Adjust Throttle Screw WITH CO/CO2 Meter

  46. TESTING EQUIPMENT IS REQUIRED • Electronic CO/CO2 Combustion Analyzers are CRITICAL for Maintaining Safe & Efficient Operation of ANY 90+ Efficiency Equipment • Allowable Carbon Monoxide (CO) emission levels in Pinnacle flue gases: Hi-Fire <100 ppm Lo-Fire < 20 ppm

  47. All PureFire Boilers are Thoroughly Tested At the Factory Factory Test Record Sheet Is Included with IOM Manual