1 / 21

Relatore: Prof. Palmucci Correlatore: T.S.R.M. Ciavola

ANDREA MORELLI. TECNICHE D’IMPIEGO DEL COLLIMATORE ASIMMETRICO NEL TRATTAMENTO RADIOTERAPICO DEL DISTRETTO TESTA-COLLO. Relatore: Prof. Palmucci Correlatore: T.S.R.M. Ciavola. Statistiche. Tumori Testa-collo. FUMO ALCOOL. INDIVIDUI ADULTI DI SESSO MASCHILE. Fattori di rischio .

onaona
Download Presentation

Relatore: Prof. Palmucci Correlatore: T.S.R.M. Ciavola

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ANDREA MORELLI TECNICHE D’IMPIEGO DEL COLLIMATORE ASIMMETRICO NEL TRATTAMENTO RADIOTERAPICO DEL DISTRETTO TESTA-COLLO Relatore: Prof. Palmucci Correlatore: T.S.R.M. Ciavola

  2. Statistiche

  3. Tumori Testa-collo

  4. FUMO ALCOOL INDIVIDUI ADULTI DI SESSO MASCHILE Fattori di rischio Incidenza

  5. Ruolo della Radioterapia • ELIMINARE LA NEOPLASIA ATTRAVERSO RADIAZIONI IONIZZANTI • MIGLIORARE LA QUALITA’ DELLA VITA • EVITARE MUTILAZIONI PRODOTTE DALLA CHIRURGIA

  6. Apparecchiatura LINAC

  7. Schema LINAC

  8. Sezione Acceleratrice

  9. Collimatori

  10. Collimatore Asimmetrico

  11. Campo Simmetrico Y X

  12. Campo Asimmetrico Y X

  13. Laringe

  14. Tumori della laringe:Segni e sintomi • DISFONIA • TOSSE • DISPNEA • DOLORI

  15. Forme Tumorali • GLOTTICI: Meno invasivi. Provocano disfonia • SOVRAGLOTTICI: Più invasivi • GLOTTICI: Rari ed insidiosi. Diagnosticati in fase avanzata.

  16. Tecnica di trattamento • TRATTAMENTO IN S.A.D. • 4 CAMPI: ANTERIORE, POSTERIORE, LAT. DESTRO, LAT. SINISTRO • ASIMMETRIA PER EVITARE LA SOVRAPPOSIZIONE • DOSE GIORNALIERA: 180 cGy • DOSE TOTALE: 5760 cGy ù • SEDUTE: 32

  17. Campo 2 Posteriore Campo 3 Laterale Destro Campo 4 Laterale Sinistro Campo 1 Anteriore Asimmetria 968 968 38 38 Campo X (mm) 64 64 75 75 Campo Y (mm) 185 175 135 135 Gantry 0° 180° 270° 90° Accessori Forato Forato Forato Forato Posizione Paz. Supino Supino Supino Supino D.F.P. 95.4 88.8 94.4 94.4 Unità Monitor 136 97 111 111 Parametri tecnici di trattamento

  18. Immobilizzazione del paziente Gantry a 0°

  19. Immobilizzazione del paziente Gantry a 180°

  20. Vantaggi Collimatore Asimmetrico • TECNICA DELL’EMICAMPO • ABOLIZIONE DIVERGENZA FASCIO • POSSIBILITA’ DI EFFETTUARE CAMPI CONTIGUI • ASSENZA DI SOVRADOSAGGIO • RISPARMIO DOSE ORGANI CRITICI, IN PARTICOLARE IL MIDOLLO CONCLUSIONI

  21. … e per finire…….. GRAZIE A TUTTI!! MAK MAX et INK CATANIA 15/11/02

More Related