Home Automation & Security Update
Download
1 / 13

Home Automation & Security Update - PowerPoint PPT Presentation


  • 433 Views
  • Uploaded on

Home Automation & Security Update Xiao Luo Software Architecture Consultant Siemens Ltd. China PC Phone A/V Home Automation & Security The Vision User friendly control of all Home Controls and Appliances via existing interfaces of Home Entertainment and Information technology components.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Home Automation & Security Update' - omer


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Slide1 l.jpg

Home Automation & Security Update

Xiao Luo

Software Architecture Consultant

Siemens Ltd. China


Slide2 l.jpg

PC

Phone

A/V

Home Automation & SecurityThe Vision

User friendly control of all Home Controls and Appliances via existing interfaces of Home Entertainment and Information technology components.


Home automation security executive summary l.jpg
Home Automation & SecurityExecutive Summary

The Home Automation & Security working committee has defined DCPs for these application areas.

  • HVAC UPnP DCP Standard

  • Lighting UPnP DCP Standard

  • Digital (Security) Camera 45-day review done

  • Blinds / Shutter / Motor Control Sample implementations

  • Power System Sample implementations

  • Security System Sample implementations


Slide4 l.jpg
HVAC

  • Approved as standard DCP

  • Complete set of standards for heating system:

    • Temperature sensors

    • Temperature setpoints

    • Valve & fan control

    • Operation modes

    • Schedule setup

Device(s)

HVAC_System

HVAC_ZoneThermostat

Service(s)

HVAC_UserOperatingMode

HVAC_FanOperatingMode

FanSpeed

TemperatureSensor

HVAC_SetpointSchedule

ControlValve

TemperatureSetpoint


Lighting l.jpg
Lighting

  • Approved as standard DCP

  • Binary Light

    • Simple switch (on/off)

  • Dimmable Light

    • Switch and

    • Dimming (value, up/down, rampTo,...)

Device(s)

BinaryLight

DimmableLight

Service(s)

SwitchPower

Dimming


Digital security camera l.jpg
Digital (Security) Camera

Next steps:

  • SC approval, then approved as standard

  • Settings

    • Saturation, Brightness, WhiteBlance, Rotation

  • Still Image

    • GetURL and specify encodings, compression, resolution

  • Motion Image

    • Still Image + framerate and bandwidth settings

Device(s)

DigitalSecurityCamera

Service(s)

DigitalSecurityCameraSettings

DigitalSecurityCameraStillImage

DigitalSecurityCameraMotionImage


Shutter blind motor control l.jpg
Shutter / Blind / Motor Control

  • Template design complete

  • Two-Way-Motion-Motor

    • TurnCW, TurnCCW

    • Aliases: Open, Close, Up, Down, Left, Right

    • Get/SetPosition, Stop, Lock

  • Looking now for Sample Implementers!

Device(s)

SolarProtectionBlind

Service(s)

TwoWayMotionMotor


Power system l.jpg
Power System

  • Template design complete

  • Sample implementation was pending becauseUPnP Security services are required for Power System devices and services (e.g. PowerMeter).

  • Looking now for Sample Implementers!

Device(s)

PowerSystem

PowerSource

PowerSink

PowerConverter

PowerStorage

UPS Device

Service(s)

PowerMeter

ProgrammableTimer

GenericPowerStorage

GenericPowerConverter

BasicPowerSummary

PredictivePowerSummary

PowerFlow

PowerSocket

Battery

Charger


Security and access control system l.jpg
Security and Access Control System

  • Template design complete

  • Sample implementation was pending becauseUPnP Security services are required.

  • Looking now for sample implementers!

Device(s)

SecurityAccessControl

Service(s)

Relay

EventLog

Display

Partition

BooleanSensor

PINPad

Reader


Generic services l.jpg
Generic Services

  • Template Design Complete

    • ExtendedDeviceInformation

      • Name/Value pairs

      • Get/SetParameter action

    • HouseStatus

      • OccupanceState, ActivityLevel, DormancyLevel

  • Useful Services for any UPnP device

  • Call for Sample Implementers!


Next steps l.jpg
Next steps

  • Digital (Security) Camera

    • SC vote

  • Blinds, Motor Control / Security System / Power System

    • Follow standardization process (sample implementations, test tool pass, 45-day review, SC vote)


Contact l.jpg
Contact

  • For further infomation, please contact

    Mr. Hans-Joachim Langels

    (hans-joachim.langels@siemens.com)