1 / 19

Comparing Simulated Showers to Data

Comparing Simulated Showers to Data. Gordon Thomson Rutgers University. Outline. Introduction: using simulations in FD analysis. Comparing Xmax means and widths. Comparing longitudinal shower profiles. Conclusions. Simulations Play a Crucial Role in FD Analysis.

oliver-gill
Download Presentation

Comparing Simulated Showers to Data

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Comparing Simulated Showers to Data Gordon Thomson Rutgers University INR Workshop, May 2008

  2. Outline • Introduction: using simulations in FD analysis. • Comparing Xmax means and widths. • Comparing longitudinal shower profiles. • Conclusions.

  3. Simulations Play a Crucial Role in FD Analysis • Calculate aperture for spectrum • 1018 eV limit is 10 km, for HiRes, Auger, HEAT, NOT TA/TALE • 1019 eV limit is 22 km • 1020 eV limit is 35 km, set by 1° pixel size (1.5° for Auger and HEAT) • Unfolding correction (necessary for SD also) • Understand biases for <Xmax> analysis • Most Important: understand your detector • Know inputs to MC; develop so MC is just like data;  Understand how detector / experiment / UHECR’s work

  4. HiRes Data / MC Comparisons TA/TALE will make plots like these. I hope someday Auger will also.

  5. “31° Bias”, for HiRes, Auger, NOT TA • Must see Xmax to measure E accurately. • For E < 1018 eV, events have to be close, and Xmax occurs above 31° in elevation. • Dangerous bias is present; enters into both spectrum and <Xmax> determination MC events must have same Xmax distribution as data.

  6. Requirements for Shower Simulation • <Xmax> must follow data • Make models (QGSJet, Sibyll, etc.) yield correct <Xmax>(E): Simulate a mixture of protons and iron • 80/20 for QGSJet01; 60/40 for Sibyll • Put real Corsika showers into MC.

  7. Results for <Xmax>, Xmax Distribution • The <Xmax> measurements of Fly’s Eye, HiRes/MIA, and HiRes stereo are shown. • Red = HiRes simulation • Blue = Fly’s Eye simulation • Black points = HiRes data • Simulation of HiRes/MIA + HiRes stereo <Xmax> works. • <Xmax> simulation agrees with data. • Xmax distribution does also.

  8. Accurate Aperture Calculation? • QGSJet01 works; Sibyll works; any reasonable model will work.  An accurate aperture calculation can be performed, with no model dependence.

  9. Study of Longitudinal Shower Profile Shapes • Previous work: • HiRes/MIA Prototype • T. Abu-Zayyad et al., A Measurement of the average Longitudinal Development Profile of CR Air showers, Astropart. Phys., 16, 1 (2001) • Now: • HiRes2 monocular data, work by Gareth Hughes • More statistics • Improved Monte Carlo • 2 orders of magnitude higher in energy range

  10. Shower Displayed in x (g/cm2) • Make quality cuts: • well defined showers • Standard spectrum cuts • Track length > 200g/cm2 •  < 110o • Extra Bracketing -50g/cm2 • Cerenkov Fraction < 0.35 • Fit to Gaisser-Hillas formula

  11. Shower Displayed in s (age) • Gaisser-Hillas: • With 2 free parameters: • Gaussian in Age: • One free parameter: •  = Shower Width • Symmetric about s=1

  12. Average Shower: Data • Black points mean of the blue • Gaussian fits in bins of age • Fit black points to normalized • Gaisser-Hillas • Gaussian in Age

  13. Average Shower: Monte Carlo • Corsika shower library • QGSJET Proton and Iron • Put through detailed Detector Simulation • Resolution

  14. Data – Monte Carlo Comparison • Top: Good agreement between Data and Monte Carlo • Black: Data • Red: Monte Carlo • Bottom: Ratio of Data/Monte Carlo • Flat from 0.6 to 1.3 in Age E > 1018.5eV

  15. Resolution in  • Energy dependant  resolution • effects profile reconstruction • Geometric bias • Top and Bottom of mirrors • Mirror edges • Compare Monte Carlo reconstructed with ‘True’ value of  and Rp • Shows us age range we can fit

  16. Fits to Average Showers • Black points mean of the blue • Gaussian fits in bins of age • Make average showers for half decade bins in energy • Good fits above 1018.5eV • 2/dof ~ few

  17. Average Shower Widths , Monte Carlo only • CORSIKA(QGSJET) • 80% Proton and 20% Iron • Get back what we put in • Consistent across all energies

  18. Data and Monte Carlo Results • Good agreement • Same falling behavior • Within errors • 3.5 difference in highest energy bin. What is this? • Low statistics (10 data events)

  19. Conclusions • Simulating UHECR showers is a crucial step in any experiment. • Both shower and apparatus simulation are important. • It is possible to perform an excellent simulation of UHECR experiments (both aperture and resolution). • One can simulate both <Xmax> and Xmax distributions to agree well with data. • We have a developed a method to study the average longitudinal profiles of showers. • Good fit for Gaisser-Hillas, and Gaussian in age. • Compared shower profile widths, in data to QGSJet01-based Monte Carlo: Shows good agreement.

More Related