html5-img
1 / 2

MSE thermal birefringence and shot to shot reproducibility

MSE thermal birefringence and shot to shot reproducibility . Motivation: MSE has poor reproducibility in q measurements Last campaign we determined this was caused by birefringence in L2 from temperature changes throughout the run day (1080523) Bench experiments support this hypothesis.

odina
Download Presentation

MSE thermal birefringence and shot to shot reproducibility

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MSE thermal birefringence and shot to shot reproducibility • Motivation: • MSE has poor reproducibility in q measurements • Last campaign we determined this was caused by birefringence in L2 from temperature changes throughout the run day (1080523) • Bench experiments support this hypothesis

  2. Thermal Management MSE thermal shield L2 mount O-ring seat • Actions taken • New L2 mount to thermally isolate lens from the MSE canister • New heat shield for temperature control of entire canister • Proposal • A few identical shots throughout a run day to check reproducibility • Preferably run days with significant RF heating for worst possible thermal environment

More Related