Detector Optimization using Particle Flow Algorithm for ILC Contents 1. Introduction 2. Particle Flow Algorithm 3. Results 4. Summary DPF2006+JPS2006 @ Sheraton Waikiki Hotel Oct. 29th-Nov. 3rd, 2006 Tamaki Yoshioka ICEPP, Univ. of Tokyo On behalf of GLD Colleagues JPS2006 @ Sheraton Waikiki Hotel
Introduction • Most of the important physics processes to be studied in the ILC • experiment have multi-jets in the final state. • → Jet energy resolution is the key in the ILC physics. • The best energy resolution is obtained by reconstructing • momenta of individual particles avoiding double counting among • Trackers and Calorimeters. • - Charged particles (~60%) measured by Tracker. • - Photons (~30%) by electromagnetic CAL (ECAL). • - Neutral hadrons (~10%) by ECAL + hadron CAL (HCAL). • → Particle Flow Algorithm (PFA) • In this talk, general scheme and performance of the GLD-PFA, • using the GEANT4-based full simulator (Jupiter),will be presented. JPS2006 @ Sheraton Waikiki Hotel
GLD Detector Muon detector • - One of the detector concepts • for the ILC experiment. • The world-wide consensus of • the performance goal for the • jet energy resolution is • For more detail, please • see the GLD Detector • Outline Document (DOD) • → physics/0607154 Calorimeter Coil Vertex detector Tracker GLD detector JPS2006 @ Sheraton Waikiki Hotel
GLD Detector Concept • To get good energy resolution by PFA, separation of particles (reducing the • density of charged and neutral particles at CAL surface) is important. Often quoted “Figure of Merit” B : Magnetic field R : CAL inner radius σ: CAL granularity RM : Effective Moliere length • GLD concept • 1. Large inner radius of ECAL to optimize the PFA. • 2. Large tracker for excellent dpt/pt2 and pattern recognition. • 3. Moderate B field (~3T). JPS2006 @ Sheraton Waikiki Hotel
GLD Geometry in Jupiter Solenoid TPC Hadron Calorimeter (HCAL) VTX, IT Muon Detector Electromagnetic Calorimeter (ECAL) Dodecagonal Shape As of October 06 JPS2006 @ Sheraton Waikiki Hotel
Calorimeter Geometry in Jupiter Readout Line =10cm 349.4cm Barrel HCAL 229.8cm Barrel ECAL 210cm 270cm Endcap HCAL Barrel.InnerRadius=210cm Endcap ECAL Endcap.InnerRadius=40cm IP Barrel.HalfZ=280cm 419.4cm 280cm 299.8cm JPS2006 @ Sheraton Waikiki Hotel
Calorimeter Structure Active Layer Absorber Current cell size : 2x2cm Can be changed. ECAL W/Scinti./Gap 3/2/1 (mm) x 33 layers HCAL Fe/Scinti./Gap 20/5/1 (mm) x 46 layers JPS2006 @ Sheraton Waikiki Hotel
Z-pole Event Display End View Side View - Z → qq (uds) @ 91.2GeV, tile calorimeter, 2cm x 2cm tile size JPS2006 @ Sheraton Waikiki Hotel
Particle Flow Algorithm for GLD Flow of GLD-PFA • Photon Finding • Charged Hadron Finding • Neutral Hadron Finding • Satellite Hits Finding • *Satellite hits = calorimeter hit cell which does not belong • to a cluster core Note : Monte-Carlo truth information is used for muon and neutrino. JPS2006 @ Sheraton Waikiki Hotel
Photon Likelihood - Five variables are selected to form the photon likelihood function. Velocity Mean Layer Track Distance Photon Other Output chi2 Edep/Nhits Other Photon JPS2006 @ Sheraton Waikiki Hotel
Particle Flow Algorithm for GLD Flow of GLD-PFA • Photon Finding • Charged Hadron Finding • Neutral Hadron Finding • Satellite Hits Finding • *Satellite hits = calorimeter hit cell which does not belong • to a cluster core Note : Monte-Carlo truth information is used for muon and neutrino. JPS2006 @ Sheraton Waikiki Hotel
Charged Hadron Finding • Basic Concept : • Extrapolate a charged track and calculate a distance between • a calorimeter hit cell and the extrapolated track. Connect the cell • that in a certain tube radius (clustering). Extrapolated Track • Calculate the distance • for any track/calorimeter • cell combination. HCAL Tube Radius Hit Cells • Tube radius for ECAL • and HCAL can be changed • separately. distance ECAL Calorimeter input position Charged Track JPS2006 @ Sheraton Waikiki Hotel
Particle Flow Algorithm for GLD Flow of GLD-PFA • Photon Finding • Charged Hadron Finding • Neutral Hadron Finding • Satellite Hits Finding • *Satellite hits = calorimeter hit cell which does not belong • to a cluster core Note : Monte-Carlo truth information is used for muon and neutrino. JPS2006 @ Sheraton Waikiki Hotel
Neutral Hadron Likelihood - Four variables are selected to form the NHD likelihood function. Output Velocity Energy Density Neutral Hadron Satellite Hits Edep/Nhits Mean Layer Neutral Hadron Satellite Hits JPS2006 @ Sheraton Waikiki Hotel
Particle Flow Algorithm for GLD Flow of GLD-PFA • Photon Finding • Charged Hadron Finding • Neutral Hadron Finding • Satellite Hits Finding • *Satellite hits = calorimeter hit cell which does not belong • to a cluster core Note : Monte-Carlo truth information is used for muon and neutrino. JPS2006 @ Sheraton Waikiki Hotel
e+ e- Yellow : Photon Red,Green : Charged Hadron Black,Blue : Neutral Hadron Z → qqbar @ 91.2GeV Event Display JPS2006 @ Sheraton Waikiki Hotel Next: 電子、陽電子衝突
Event Display Yellow : Photon Red,Green : Charged Hadron Black,Blue : Neutral Hadron Gamma Finding JPS2006 @ Sheraton Waikiki Hotel
Event Display Yellow : Photon Red,Green : Charged Hadron Black,Blue : Neutral Hadron Charged Hadron Finding JPS2006 @ Sheraton Waikiki Hotel
Event Display Yellow : Photon Red,Green : Charged Hadron Black,Blue : Neutral Hadron Remove Satellite Hits JPS2006 @ Sheraton Waikiki Hotel
Event Display Yellow : Photon Red,Green : Charged Hadron Black,Blue : Neutral Hadron Remaining : Neutral Hadron JPS2006 @ Sheraton Waikiki Hotel
Jet Energy Resolution (Z-pole) - Z → uds @ 91.2GeV, tile calorimeter, 2cm x 2cm tile size All angle • Almost no angular dependence : 31%/√E for |cosq|<0.9. • cf. 60 %/√E w/o the PFA (sum up the calorimeter energy) JPS2006 @ Sheraton Waikiki Hotel
Performance - Energy-weighted Efficiency and Purity Definition Efficiency : xxx (total xx E in collected hits)/(true xxx total E in CAL) Purity : Pxxx (total xxx E in a cluster)/(total E in a cluster) xxx = Photon, CHD, NHD, Satellite both and P values are energy-weighted JPS2006 @ Sheraton Waikiki Hotel
Jet Energy Resolution - Energy dependence of jet energy resolution. - Jet energy resolution linearly degrades. → Need to improve. JPS2006 @ Sheraton Waikiki Hotel
Summary • Realistic PFA has been developed using the GEANT-4 based full simulator of the GLD detector. • Jet energy resolution is studied by using Z→qq events. ILC goal of 30% has been achieved in the barrel region of the Z-pole events. • By using the PFA, we are going to optimize the detector parameters such as the calorimeter granularity, radius etc. JPS2006 @ Sheraton Waikiki Hotel