MIM Case Study – Contact. Application : Medical Electronics Functional Requirements : Structurally intact; low thermal expansion Competing Technology : Stamped flat base, welded wire for posts Overall Size : Base 0.25 mm thick, 1.25 mm square Posts 0.5 mm diameter x 1.2 mm tall
E N D
MIM Case Study – Contact • Application: Medical Electronics • Functional Requirements: Structurally intact; low thermal expansion • Competing Technology: Stamped flat base, welded wire for posts • Overall Size: • Base 0.25 mm thick, 1.25 mm square • Posts 0.5 mm diameter x 1.2 mm tall • Part Weight: 0.007 grams • Material: MIM-Alloy 42, subsequent Ni & Au plating
MIM Case Study – Contact • Small Part! • MIM to replace existing process: • Base stamped out of gold-plated sheet • Posts made from wire form welded to base • - MIM seen as a cost savings with better consistency
Key Characteristics- Contact One of two posts intact No cracks Minimal flash Posts strong enough to not deflect when wire is welded to posts; center support section added Parts needs to be solderable to the circuit board; bumps molded in to allow flow of solder under part
MIM Case Study – Contact • Why MIM? • More consistent position of posts • Connection of the posts to the base is more reliable in a one-piece MIM part than the welded wire to the stamped base. • MIM Alloy 42 consistent with expected material properties • Economics of MIM regarding CAPEX, part price significantly better than stamp & weld • MIM a more repeatable for high-volume technology for this application