An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Paper ID: 20100982 IMPROVING ENERGY EFFICIENCIES OF CRUDE PREHEAT EXCHANGERS BY SEQUENCING OF CRUDE OILS – A STUDY JAYA RAWAT, DHANEESH VS,P.V.C. RAO & N.V. CHOUDARY BPCL, Corporate R&D Center Greater Noida

  2. OUTLINE OF PRESENTATION • Fouling problems in crude pre-heat exchangers • Fouling - chemistry • Reasons for fouling • Remedial measures for fouling • Sequencing of crude oils for improving crude pre-heat efficiency • Case Studies • Case -1 • Case-2 • Case-3 • Conclusions

  3. FOULING CHEMISTRY • Fouling is defined as the formation of an unexpected phase (solid, liquid or gas) hydrocarbon-based deposits on heat exchanger surfaces that interferes with processing. • First fouling layer has low thermal conductivity, which increases the resistance to heat transfer and reduces the effectiveness of the heat exchangers. • Second, as deposition occurs, the cross-sectional area is reduced, which causes an increase in pressure drop across the apparatus and creates inefficient flow in the heat exchanger.

  4. FOULING MECHANISM

  5. CAUSES OF FOULING • Organic • Insoluble Asphaltenes • Incompatible Oils on Mixing • Self-Incompatible Oils • Coke: Insoluble Asphaltenes at Thermal Cracking Temperatures • Polymerization of Conjugated Olefins • Inorganic • Sea Salts: Sodium, Calcium, and Magnesium Chloride • Iron Sulfide and Iron Oxide: Corrosion Products • Ammonium Chloride from units • Aluminum Silicate: Clay or Catalyst Fines Assuming desalter functioning proper, there can be two causes for fouling; first is incompatibility & second is fouling tendency of crude itself.

  6. FOULING MITIGATION STRATEGY • Diagnosis: Determine the cause of fouling. • Process conditions/history • Analysis of Foulant • Analysis of oil flowing through fouling unit • Investigation: Trace the cause to the source. • Determine each step in the progression from incoming crude oil through upstream units until the foulant is deposited in the fouled unit. • Innovation: Device ways to interrupt/reduce foulant precursors at each step. • a range of ideas of how to stop or interrupt each step in the progression from precursor in the crude oil to deposited foulant. • Mitigation: Select the best of these ways for the particular refinery to implement. • establish a quantitative measure of success to evaluate and to test the preferred mitigation action and make a recommendation

  7. WAYS ADOPTED TO MINIMIZE FOULING • Off-line cleaning of heat exchanger tube bundles by chemical or mechanical cleaning. However, off-line cleaning interrupts regular services and also results in to period of non-production. • Online is a better strategy to address the fouling problems proper selection of crude oils which have cleaning properties so that foulants created by one crude can be cleaned by another crude oil. • Role of aromatic solvents and aromatic component of the crude oils play a significant role in this study. • Reversal of crude blend ratios has also been depicted here as one of the important step in order to reduce fouling in crude –preheat exchangers.

  8. SEQUENCING OF CRUDE OILS FOR IMPROVING CRUDE PRE-HEAT EFFICIENCY • Selection of sequence of crude oil processing in such manner so that foulants created by one can be cleaned by next one • This strategy involves • Determination of fouling nature of crude oils • Assessment of nature of foulants by SARA analysis • Identification of cleaning crude • Lab/pilot scale trials for the crude sequencing • Chemicals analysis of foulants at each step.

  9. TOOLS FOR IMPROVING ENERGY EFFICIENCIES OF CRUDE PREHEAT EXCHANGERS

  10. WORK PLAN • Recommended strategy is to use key indicators and knowledge of the most common causes of refinery fouling to determine the cause of fouling • Once the cause is determined, the foulant precursors are traced to the source. • By stopping the foulant precursors from forming, the unexpected foulant phase can be eliminated from the refinery completely. CASE -1 Crude exchanger’s fouling reduction by aromatic solvents CASE -2 Crude exchanger’s fouling reduction by sequencing of crude oils CASE-3 Crude exchanger’s fouling reduction by reversing the crude blend ratios

  11. METHODOLOGY 1. TLC-FID analysis The SARA (asphaltenes, saturates, resins and aromatics) analysis of crude oils and fouling deposits were with Thin Layer Chromatography-Flame Ionization Detection (TLC-FID) technique. Asphaltene + saturates CII = Resins + Aromatics • CII values > 0.9 and higher is considered as indication for instability • 0.6-0.9 is good stable range.

  12. 2. THERMAL FOULING TEST METHODOLOGY…………CONTD Hot Liquid Process Simulator (HLPS) – a useful tool for predicting heat exchanger performance and the fouling tendencies of specific process fluids HLPS was operated in single-pass mode and the data was generated at constant heating medium temperature of 380ºC temperature, 700 psi pressure for duration of 5 hours at 3.0 ml/minute flow rate

  13. METHODOLOGY- …… CONTD DISPERSION STABILITY OF ANTIFOULANT Without antifoulant, deposits seen at the bottom With antifoulant, no deposits, fully dispersed

  14. Crude exchangers fouling reduction by aromatic solvents CASE STUDIES -1 • Fouling behavior of three crude blends 1,2 & 3 were studied Table:-1 Typical properties of crude blend Table -2:- Comparison of Fouling parameters of crude oils • Crude blend-3 has shown the maximum fouling tendency among the studied crudes.

  15. CASE STUDIES -1 . ………CONTD • The deposits obtained from crude blends1, 2 and 3 fouling test were collected and analyzed for their foulants characteristics. The fouling in case of all the three crude blends was mainly due to high paraffinic components. • Cleaning experiments were carried out in HLPS with aromatic solvents mixture (in-house prepared) for their suitability for the dissolution of deposits on fouled tubes. • It has been observed that with aromatic solvent blend-1 the circulation time and temperature (3.5 hr & 900C) required are higher than aromatic solvent blend -2 (2 hr & 800C). The mixture of these two has shown comparatively good results in less circulation time.

  16. Crude exchangers fouling reduction by sequencing of crude oils CASE STUDIES -2 • SELECTION OF CLEANING CRUDE Based on the results obtained from CASE-1, It was observed that the aromatic fractions contribute a lot in fouling reduction, so that if crude are selected in such manner so that the deposits created by one crude can be cleared by another one, similarly aromatic rich crudes may be processed to reduce the fouling in heat exchanges and it expected to clear the deposits created by the earlier processed crudes.

  17. CASE STUDIES -2. ………CONTD Table 3:- Typical crude properties of cleaning crudes • The crude blends 1-3 lie are low in sulphur and asphaltene and their fouling deposits are highly paraffinic. • It is evident from Table-4 that cleaning crude-2 is more aromatic and less asphaltenic as compared to cleaning crude-1.

  18. CASE STUDIES -2. ………CONTD Table: 4 HLPS test run with cleaning crudes for dissolution of deposits on tube • Based on the above study it was observed that crude oils with low sulphur, less asphaltene and higher aromatics content should be preferred as cleaning crude. • The cleaning property can be successfully achieved by alternately charging with non-fouling or cleaning crude in order to minimize fouling in the heat exchangers.

  19. CASE STUDIES -3 Crude exchangers fouling reduction by reversing the crude blend ratios Table-5: Physical properties of crude oil A & B • Crude A and B are non-fouling crude when processed neat • whereas higher blends of crude A such as A70 and A80 have shown very high fouling.

  20. CASE STUDIES -3. ………CONTD. Fouling behavior of crude blends with different blend ratios • Crude A and B are non-fouling crude when processed neat, whereas higher blends of crude A such as A70 and A80 have shown very high fouling. • During the experiments it was observed that, when ratio of crude B was increased in the blend -the fouling mitigation trends was observed.

  21. CASE STUDIES -3. ………CONTD. • A20 and A30 blends are less than 0.9, which means that these blends are stable, whereas the CII values obtained for A50, A70 and A80 blends are higher than 0.9 indicating instability of these crude blends. • Further it was also observed that this phenomenon has been observed in case of crude blend with high and low pour point, where if percentage of low pour crude is increased in crude it further helps in fouling reduction. Table-6: CII values of crude blends

  22. Fouling in crude pre-heat exchangers can be managed through the proper sequencing of crude oils • Low sulphur, less asphaltene and higher aromatics content crudes can be selected as cleaning crude in case of fouling of paraffinic crudes. • Crude oils with cleaning behavior can prevent or even reverse the fouling caused by other crude oils. • Fouling can also be reduced by proper managing the crude blend ratios. In some cases it can be reversed even by changing the crude blend ratios • By alternately charging non-fouling or cleaning crude and fouling crudes, heat exchangers of crude pre-heat train can be maintained in the clean condition. ACKNOWLEDGEMENTS • The authors are grateful to ED (MR/R&D), BPCL for his constant encouragement and guidance in publishing this work. CONCLUSIONS

  23. REDUCE CORROSION THANKS FOR YOUR KIND ATTENTION REDUCE FOULING

  24. H/C Atomic Foulant 1.4 – 1.9 Wax 1.0 – 1.2 Unconverted Asphaltenes 0.7 – 1.0 Thermally Converted Asphaltenes 0.3 – 0.7 Coke