Integrated Wind-Hydrogen Systems for Wind Parks

Integrated Wind-Hydrogen Systems for Wind Parks. E. Varkaraki, N. Lymberopoulos, E. Zoulias, E. Kalyvas , C. Christodoulou, P. Vionis, P. Chaviaropoulos. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS. _____________________________________________________. OUTLINE OF THE PRESENTATION.

marion
Download Presentation

Integrated Wind-Hydrogen Systems for Wind Parks

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Integrated Wind-Hydrogen Systems for Wind Parks E. Varkaraki, N. Lymberopoulos, E. Zoulias, E. Kalyvas , C. Christodoulou, P. Vionis, P. Chaviaropoulos

  2. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ OUTLINE OF THE PRESENTATION • System description • Hydrogen generation section • Hydrogen compressor & Filling station • Metal hydride tanks • Auxiliaries • Power and Control • Results and Discussion • Conclusions

  3. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ SYSTEM DESCRIPTION • 500 kW gearless, synchronous, multipole Enercon E-40 • 25 kW alkaline electrolyser, 5 Nm3/h H2 at 20 bar • One-stage hydrogen compressor up to 220 bar • Filling station for high pressure cylinders, 120 Nm3 H2 • Metal hydride tanks, 42 Nm3 H2 • Water chiller and closed cooling circuit • Instrument air compressor • Power board • Control and monitoring section based on PLC • Developed in the frame of the EU project RES2H2 (FP5)

  4. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ SYSTEM DESCRIPTION

  5. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ HYDROGEN GENERATION SECTION Casale Chemicals SA, Switzerland Alkaline electrolyser 25 kW Power operating range: 20-100% DC operation: 0 - 300 A, 0 - 120 V H2 production: 0.45 kg/h (5 Nm3/h) H2 purity: 99.98%v. (after purification) Demineralised water consumption 4.1 l/h Electrolyte: KOH solution 30%w.

  6. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ HYDROGEN COMPRESSOR & FILLING STATION PDC Machines Inc., USA Single-stage hydrogen compressor Triple metal diaphragm Inlet pressure: 10 – 18 bar Inlet temperature: 30 - 40C Outlet pressure: 220 bar 5 Nm3/h at 14bar/40C inlet Buffer: 360 L volume Filling station: 10.7 kg H2 (120 Nm3)

  7. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ METAL HYDRIDE TANKS FIT, Cyprus & Labtech SA, Bulgaria 6 Metal Hydride tanks Metal alloy: La0.75Ce0.25Ni5 Total hydrogen capacity: 3.78 kg H2 (42 Nm3) Total weight: 564 kg Mass specific H2 capacity: 1.28 %w (alloy) 0.66 %w (MHT) Hot water boiler 4 kW

  8. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ AUXILIARIES WATER CHILLER Cooling water in closed circuit Mean electrical power requirement: 1.5 kW INSTRUMENT AIR COMPRESSOR Pneumatic valve actuation Mean electrical power requirement: 0.2 kW NITROGEN Inertisation of electrolyser and hydrogen circuit

  9. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ POWER and CONTROL

  10. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Electrolyser operation 29.12.05

  11. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Electrolyser operation DC current measurement, 1 kHz DC current applied: 120 A AC/DC conversion efficiency 85-90% at full power 70-75% at 20% of full capacity

  12. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Electrolyser operation Variable power input

  13. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Electrolyser operation Protective polarisation Mean values: DC current: 2.5 A DC voltage: 61 V DC power: 0.15 kW AC power: 0.35 kW • Protective polarisation applied for 27 weeks consumes 1.6 MWh • NO protective polarisation thanks to activated electrodes!

  14. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Electrolyser operation Stack efficiency: 70-80% (HHV) AC power efficiency: 55-65% (HHV)

  15. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Electrolyser operation filling the buffer At 1:30 start compressor filling one HP cylinder Overall electrical efficiency from AC power to compressed H2: 50% (HHV)

  16. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION Metal Hydride Tanks operation Preheating phase Winter conditions 4 kW boiler operating 2 hours P mht: 18 bar

  17. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ RESULTS and DISCUSSION • Several lessons learned from the realisation of the plant until now: • Interfacing of the various units is key, in relation to hydrogen flow, electricity • and information flow • - Minimisation of buffer tank volume • - Transportation and installation issues in remote areas with poor access • - PLC based control system is safer but less flexible than PC based • Protection of hardware from nature’s elements, theft and even wild animals • Special care for the integration of auxiliaries, vital for safe operation

  18. INTEGRATED WIND-HYDROGEN SYSTEMS FOR WIND PARKS _____________________________________________________ CONCLUSIONS • The wind-hydrogen system installed at the wind park of CRES operates well • System efficiency from AC power to compressed hydrogen fuel: 50% (HHV) • Important margins for efficiency increase • power electronics of the electrolyser • wind turbine – electrolyser interface

  19. THANK YOUFOR YOUR ATTENTION!