An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AQT90 FLEX Radiometer Medical ApS

  2. RADIOMETER PRESENTATION Radiometer overview • No. of employees: 1,900 worldwide • Products sold in more than 100 countries • World leader in blood gas testing • Develops blood gas and immunoassay analyzers as well as transcutaneous monitors and sensors • Solutions for lab and point-of-care testing as well as patient monitoring

  3. RADIOMETER PRESENTATION AQT90 FLEX

  4. RADIOMETER PRESENTATION POCT - End-user needs

  5. RADIOMETER PRESENTATION AQT90 FLEX parameters • Infection marker • CRP Hemostasis marker • D-dimer Pregnancy marker • ßhCG • Cardiac markers • Myoglobin • CKMB • Troponin I • NT-proBNP • Troponin T

  6. The AQT Measuring Cup & Technology

  7. RADIOMETER PRESENTATION AQT measuring technology- Time resolved Flourescence (TRF) Whole Blood Unbound material will be washed off and cup dried ... plus buffer ... and signal read out ... stirred and incubated for a while 340 nm ... added to the cup • Measurement cycle lasts 1 ms, repeated 1000 times • Measuring time = 1s Improved Specificity

  8. RADIOMETER PRESENTATION 2 3 1 AQT90 FLEXEasy testing - Testing in 3 steps Just choose the parameters and press start • Place the closed tube directly into the inlet • Choose parameters on screen and press start • Results are printed and sent to the HIS/LIS or directly to patient monitors

  9. RADIOMETER PRESENTATION AQT90 FLEXEasy Logistics • Always ready - no need for filling analyzer with consumables before each test • High on-board capacity - up to 240 test • Only two types of consumables • Cartridge • Reagent Pack

  10. RADIOMETER PRESENTATION 15 AQT90 FLEXEasy logistic - Cartridge • Each parameter-specific cartridge contains up to 16 test cups • The instrument can be loaded with up to 15 cartridges according to your needs - maximum 240 tests • Long term storage at 2-8 degrees C. • Pre-barcoded cartridges for automatic loading into analyzer • Ensures minimum time spent on replacements

  11. RADIOMETER PRESENTATION AQT90 FLEXEasy logistic – Reagent Pack • Same Reagent Pack for all parameters • 1 Reagent Pack contains reagents and waste container for 200 tests • 1 month on-board stability • Storage at room temp • Reagent Pack is discarded after use

  12. RADIOMETER PRESENTATION Correlation AQT90 FLEX TnI vs TnI Ultra n = 220 50 y = 0.148x - 0.012 2 R = 0.98 Correlation AQT90 FLEX TnI vs Architect TnI n = 174 AQT90 FLEX troponin I ng/mL 0.5 y = 0.270x + 0.003 2 R = 0.90 AQT90 FLEXX troponin I ng/mL 0 0 300 Centaur TnI Ultra ng/mL 0 0 1.6 Architect TnI ng/mL Correlations vs other TnI methods

  13. RADIOMETER PRESENTATION Correlation with Roche TnT AQT TnT assay compared with Roche 4th & 5th Generation TnT assays on Elecsys 2010. Analytical specificity TnI The limit of detection has been determined to be <0.01 ug /L. Reportable range : 0.010 – 50 ug/L TnT The limit of detection has been determined to be 0.010 ug/L . Reportable range ; 0.010 –25 ug/ L Reference values ; TnI The 99th percentile was determined to be 0.023ug/L [4] TnT The 99th percentile was determined to be 0.017ug/L [4]

  14. RADIOMETER PRESENTATION AQT90 Vs Cobas h232

  15. RADIOMETER PRESENTATION AQT90 Vs Triage / Biosite

  16. RADIOMETER PRESENTATION AQT90 Flex - Uniqueness of assays • Troponin : • AQT Troponin assays are not sensitive to autologous antibodies hence lower probability of false negatives • AQT Troponin assays are not affected by haemolysates • AQT Trop I assays has good correlations with most other laboratory system assays • AQT Trop T assay has excellent correlations with Roche 4th & 5th (hsTnT) Generation Trop T assays. • D-Dimer : • Higher specificity compared to any of the D-Dimer assays on market. • AQT D-Dimer specificity – 71% and Sensitivity – 98% • AQT D-Dimer assay linearity upto 100,000 ug/L on whole blood • Automatic Onboard dilution • Can use citrated sample also • NT-proBNP : • Lab equivalent measuring range – 12 – 35,000 pg/ml

  17. RADIOMETER PRESENTATION AQT90 FLEX Truly meeting all end-user needs

  18. Simpler Faster Better AQT90 FLEX