ABL800 FLEX Introduction. RTC, December 2004. Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com. Agenda. Front view Rear view Modular design Parameters Analyzer configurations Specifications Sampler types AutoCheck Screen design.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, radiometer' - brody-shields


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

ABL800 FLEX

Introduction

RTC, December 2004

Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com

agenda
Agenda
  • Front view
  • Rear view
  • Modular design
  • Parameters
  • Analyzer configurations
  • Specifications
  • Sampler types
  • AutoCheck
  • Screen design
front view
Front view
  • Aspiration inlet
  • Barcode reader
  • Color touch screen
  • Printer
  • Solutions (cleaning calibration, rinse and waste containers)
  • AutoCheck
  • CD-RW drive
  • Window to electrode modules

3

8

1

4

7

6

5

5

2

rear view
Rear view
  • Screen, rear
  • Gas containers
  • Communication ports
  • Power switch
  • Fan

1

2

2

3

5

4

communication ports
Communication ports
  • The two USB communication ports provide connection to external devices, e.g. network, keyboard, USB storage device
  • The two other communication ports provide connection to mouse and keyboard
  • Furthermore there is a printer port, a network connector, a serial port and a port for an external CRT VG monitor

2

1

3

1USB

2Mouse/keyboard

3Network connections

modular design
Modular design
  • Allows flexibility in parameter availability

1

2

3

4

1Inlet

2pH/BG

3Met/Lyt

4 Oximetry

parameters
Parameters
  • There are 10 electrode slots in the two electrode modules
  • One electrode slot for the reference electrode
  • Nine other electrodes available for the following parameters:

pH, pCO2, pO2, cK+, cNa+, cCa2+, cCl–, cGlucose, cLactate

oximetry parameters
Oximetry parameters

ctHb = concentration of total hemoglobin

sO2 = oxygen saturation %

FO2Hb = fraction of oxyhemoglobin

FCOHb = fraction of carboxyhemoglobin

FHHb = fraction of deoxyhemoglobin

FMetHb = fraction of methemoglobin

FHbF = fraction of fetal hemoglobin

ctBil = concentration of bilirubin

analyzer configuration
Analyzer configuration

BG OXI ctHb/sO2 ctBIL/FHbF LYT MET

835

830

825  

820 

815

810

805

800

Models ABL835, ABL830 and ABL800 of the ABL800 FLEX analyzers are not available at the time of the release

specifications analysis details
Specifications – analysis details
  • Sample volumes
    • Macromodes 195 L (all parameters)
    • Micromodes 35-95 L (all parameters)
  • Measuring time
    • Macromodes 80 sec., cycle time 150 sec., approx. 24 samples/hr
    • Micromodes 80-135 sec., cycle time 145-200 sec., approx. 18 samples/hr
  • Derived parameters
    • 47 different derived parameters to choose from. See the types and definition in teh ABL800 FLEX Specification sheet
specifications communications
Specifications - communications
  • Computer specification
    • Intel Celeron Processor
    • Windows XP embedded
  • True multi-tasking system
    • Intel Celeron processor for DMS software
    • Dedicated 80386 CPU for wet section
  • Communication
    • LIS/HIS communication based on ASTM and HL7
    • Network communication – Ethernet (TCP/IP protocol as communication protocol)
    • True two-way communication
customizable
Customizable
  • Very comprehensive setup programs
    • More functions than ever can be customized
    • Examples: operators and passwords, corrective actions, reference and critical ranges etc.
  • Automatic restart after replacements
  • On-line help systems
    • Video tutorials
    • Help
    • troubleshooting
  • Connection to RADIANCE
    • Especially analyzer remote control module
sampler types
Sampler types

Capillary tube

QC with adapter

Syringe

Expired air

Test tube

autocheck
AutoCheck
  • Automated QC measurements
  • Eliminates user-to-user

variance - results only reflect

analyzer performance

  • Time-saving
  • Holds 20 ampoules
color touch screen
Color touch screen
  • Operation and management of the analyzer are performed via the color touch screen
  • The screen is divided into three sections
  • Top section/status bar varies slightly according to the status of the analyzer and setup
  • Center section contains the main information and interaction area
  • Bottom section contains navigation buttons and varies slightly according to the screen in question

1

2

3

1 Top section

2 Center section

3 Bottom section

top section
Top section
  • The status bar describes the current task
    • E.g. calibration, rinse, aspiration
    • The time bar is present when the analyzer is performing a task
  • The parameter bar lists all the measured parameters available and activated
  • The traffic light gives an overview of various analyzer activities and the traffic light color shows the overall status of the analyzer – see the “02 What is what” presentation for a further description

3

1

2

1 Status bar

2 Parameter bar

3 Traffic light

center section
Center section
  • The center section is the main information and interaction area
  • Each screen is identified by an icon and a name that matches the button that gives access to it
  • The screen may contain text, check buttons, scroll bars, a screen keypad or screen keyboard
bottom section
Bottom section
  • The bottom section changes with the different options, depending on the screen in question
  • In the Ready screen
    • Access various information, e.g. the current time, next QC, if connected to RADIANCE
    • The buttons can be selected to give access to e.g. Logon/Log Off, the Menu
  • General navigation buttons
    • “Close” – close actual window
    • “Back” – go one step backwards
  • Other navigation buttons
    • Results, ID, messages, print, etc.

1

Quality Control Result screen:

2

3

1 Main menu

2 General navigation buttons

3 Other navigation buttons

slide19

Radiometer Training Center, December 2004

Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com