120 likes | 251 Views
This document features a comprehensive analysis of peak power calculations presented by Bob Surette, Director of Sales Engineering at Shively Labs®, on April 17, 2009. The calculations include evaluations of digital peak power with various injection levels, showcasing methodologies for determining power outputs across different configurations. With a focus on precise methodologies, the document serves as a vital resource for engineers involved in sales and technical applications related to peak power management.
E N D
PREC 2009 To10 dBor NotTo10dB Bob Surette Director of Sales Engineering Friday April 17, 2009
Mt. Mansfield, VT October 2006
Mt. Mansfield, VT October 2006
Left Right Shively Labs®
(√ T1 + √ T2 + √ T3 +√ Tn ) 2 (√ 30+ √ 30 + √ 30+√ 30) 2 (4√ 30 ) 2 Peak Power Calculation 16 X 30 = 480 KW
(√ 30+ √ 0.3 + √ 30+√ 0.3) 2 =142 KW (√ 30+ √ 1.2 + √ 30+√ 1.2) 2 = 173 KW (√ 30+ √ 12 + √ 30+√ 12) 2 = 320 KW 20 dB Injection Average Digital Peak Digital 10 dB Injection Peak Digital
(√ 30+ √ 12) 2 = 80 KW Shively Labs®
4 1/16 Coax (√ 30+ √ 12 + √ 12) 2 = 154 KW Shively Labs®
PREC 2009 Questions Bob Surette Director of Sales Engineering Friday April 17, 2009