1 / 2

NSF NO3/NO2 RO Performance Test: Coway 8-Inch S-Type 3 Set Evaluation

Conducting NSF NO3/NO2 RO performance tests on Coway 8-Inch S-Type 3 membranes under varying test conditions including influent challenge concentrations, pressure, pH, temperature, and recovery rate. Pre-RO testing involves TDS reduction rate assessment. Results summary includes reduction rates for Sodium Nitrate and Sodium Nitrite in influent challenge water makeup. Detailed data analysis provided.

macey-eaton
Download Presentation

NSF NO3/NO2 RO Performance Test: Coway 8-Inch S-Type 3 Set Evaluation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NSF NO3/NO2 RO Performance TEST • [Test Condition] • - RO membrane : Coway 8 Inch S Type 3 set at each Condition • Influent challenge conc(mg/L) : 120 & 300 as Total Nitrogen • Pressure : 50 PSI & 100 PSI • Sampling Time : 4 hrs & 8 hrs • Recovery rate : 50 % • pH_: 7.2 ~ 7.3, Temperature : (20 ± 5) ℃ • Pre RO TEST : TDS reduction rate > 88 % (by Tap water) [Influent challenge water Make-up] - Standard : RO + Sodium Nitrate(NaNO3) & + Sodium Nitrite(NaNO2) by 1 ton Tank [Result Summary : Reduction rate(%)]

  2. NSF NO3/NO2 RO Performance TEST : DATA