This presentation by Dan Hansen Christensen Associates Energy Consulting provides an overview of the issue of fixed cost under-recovery by utilities and explores various regulatory and rate design strategies to mitigate the revenue loss. Topics covered include revenue decoupling, forecast test years, lost fixed cost recovery mechanisms, riders/cost trackers, higher fixed charges, declining block rates, DG rates, and time-differentiated rates.

lmalik
Download Presentation

Strategies for Addressing Fixed Cost Recovery Issues

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Strategies for Addressing Fixed Cost Recovery Issues Dan Hansen Christensen Associates Energy Consulting August 2014

  2. Outline • Overview of issue • Regulatory strategies • Revenue decoupling • Forecast test years • Lost fixed cost recovery mechanisms • Riders / Cost Trackers • Rate design solutions • Higher fixed charges • Declining block rates • DG rates (access charges, buy all / sell all) • Time-differentiated rates

  3. Utility Fixed Cost Recovery Issues • Traditional regulated rates recover fixed costs through volumetric rates • This leads to utility revenue attrition when sales decrease, without a corresponding reduction in costs • Some incentive issues are also created: • Utility disincentive to promote conservation and energy efficiency • Utility incentive to increase customer usage • Subsidy to distributed generation (DG) customers • Incorrect price signals to customers, compared to marginal cost to serve (caveat: environmental externalities)

  4. Sources of Utility Fixed Cost Under-recovery • Distributed generation (residential solar) • Conservation and energy efficiency • “Naturally” occurring or based on customer initiative • Improved appliance efficiency • Phasing out incandescent light bulbs • Building standards • As caused by conservation mandates • Poor economic conditions • Mild weather conditions Stakeholders will not necessarily want to treat all of these causes equally

  5. Consequences of Utility Fixed Cost Under-recovery • In the absence of other solutions, the utility will likely file a rate case to increase rates in order to mitigate under-recovery going forward • Does not allow the utility to recover lost revenues in between rate cases • In some situations, cross-subsidies may be created • Non-solar customers subsidizing solar customers • Non-conserving customers subsidizing conserving customers • There is disagreement on the extent to which such cross-subsidies occur, if at all • Rate cases may be filed more frequently

  6. Potential Solutions for Utility Fixed Cost Under-recovery Issues • The following slides present a variety of potential solutions to the issue described here • Each is summarized in terms of how it addresses the following issues: • Conservation-induced sales reductions • Sales lost to distributed generation • Sales changes due to economic conditions • Sales changes due to weather conditions • Effect on low-use customers, who some believe are more likely to be low-income customers • Discussion, as applicable, of whether cross-subsidies are affected (created or removed)

  7. Regulatory Solutions

  8. Forecast Test Year Description • Using a forecast test year (as opposed to an historical test year) can allow the expected effects of conservation or DG generation to be incorporated into rates • Expected effects will likely differ from actual effects • It does not affect rate structure or incentives (utility or customer) once in place • Even with a forecast test year, the utility is better off if it underachieves the conservation forecast (barring other penalties)

  9. Future Test Year Scorecard • Conservation • Does not remove the utility’s disincentive to promote conservation • Does not affect customer-level incentive to conserve • Distributed Generation • Makes utility whole for expected (not actual) net metering revenue losses • Does not end cross-subsidies to DG customers • Economy • No effect • Weather • No effect • Low-use customer effect • No effect

  10. Revenue Decoupling Description • Revenue decoupling is intended to remove the link between sales and utility revenues • This link exists because some fixed costs are recovered through volumetric (e.g., $ per kWh) rates • By removing the link, the utility is made indifferent to customer usage levels • Does not provide the utility with an incentive to promote conservation • A separate mechanism can do that, if desired

  11. Basic Decoupling Concept • Basic concept of revenue decoupling (RD): RD Deferral = Allowed Revenue – Actual Revenue • A positive number means the utility under-recovered, and will lead to a future rate increase • A negative number means the utility over-recovered, and will lead to a future rate decrease

  12. Basic Decoupling Concept (2) • Typically every 6 or 12 months, the RD deferral is rolled into rates as follows: Rate change from RD = RD Deferral / E(Usage) • Revenue is usually “re-coupled” to other (non-sales) factors, such as • The number of customers served (called revenue per customer decoupling, or RPCD) • Allowed revenue can be linked to inflation factors, which can incorporate performance-based regulation components

  13. Decoupling Scorecard • Conservation • Removes the utility’s disincentive to promote conservation • Does not affect customer-level incentive to conserve • Distributed Generation • Makes utility whole for net metering revenue losses • Does not end cross-subsidies to DG customers • Economy • Surcharges following recessionary years, rate reductions following expansionary years • Weather • May or may not be included (varies by mechanism) • Low-use customer effect • Only if they are less likely to conserve

  14. Lost Revenue Adjustment Mechanisms (LRAMs) Description • LRAMs compensate the utility for lost revenues due to utility-sponsored conservation programs • Fixed amount per kWh conserved, as measured in the program evaluation process • LRAMs are more narrow in focus than decoupling • Do not adjust revenues for weather, economic factors • Does not address the utility’s incentive to increase sales • Cannot lead to a rate reduction • Utility may not want to promote programs for which the effects are not easily measured • Can be significant disputes regarding kWh savings estimates

  15. LRAM Scorecard • Conservation • Addresses revenue loss from utility-sponsored programs • Does not otherwise affect conservation / load growth incentives • Distributed Generation • No effect • Economy • No effect • Weather • No effect • Low-use customer effect • Bill increase for low-use customers who do not participate in conservation programs (because they pay the LRAM adder)

  16. Riders / Cost Trackers: Description • Riders may be used to track specific costs and recover them through rates, without the need to file a rate case • E.g., commonly applied to fuel costs • In the context of this discussion, a rider could be used to track revenue attrition from net metering (if DG is separately metered) for recovery across all sales • Decoupling is a form of a rider • Because riders can vary so much, we do not provide a scorecard

  17. Rate Design Solutions

  18. Higher Fixed Charges:Description • The fixed cost recovery issue is caused by the recovery of fixed costs through volumetric rates • The problem can be mitigated or eliminated by increasing the amount of revenue recovered through fixed charges • Straight-fixed variable (SFV) pricing: recover all fixed costs through the monthly customer charge • Substitute for decoupling • Can lead to very large % bill impacts for low-use customers • Graduated facilities charges (GFCs): the monthly customer charge varies with usage (e.g., based on the 12-month average) • Can allow for an increase in the average customer charge while mitigating the effect on low-use customers

  19. Higher Fixed Charges:Example Bill Impacts

  20. Higher Fixed Charges Scorecard • Conservation • Removes the utility’s disincentive to promote conservation • Reduces the customer-level incentive to conserve • Distributed Generation • Removes DG subsidy • Removes utility revenue loss from net metering • Economy • Utility fixed-cost revenue (and customer bills) do not vary with economic conditions • Weather • Utility fixed-cost revenue (and customer bills) do not vary with weather conditions • Low-use customer effect • Potential for very high % bill impacts unless GFCs are employed

  21. Declining Block Rates:Description • The rate decreases as usage increases, for example: • 0 to 300 kWh/mo = 10 cents/kWh • 301 to 600 kWh/mo = 8 cents/kWh • Over 600 kWh/mo = 6 cents/kWh • Recovers fixed costs in the initial pricing block, in which all customers consume energy • For higher-use customers, the marginal price more closely reflects the marginal cost to serve • Compared to a flat rate: • Reduces customer-level incentive to conserve for high-use customers • Increases customer-level incentive to conserve for low-use customers • Inclining block rates are more fashionable because of the conservation incentives

  22. Declining Block Rate Scorecard • Conservation • Reduces the utility’s disincentive to promote conservation • Customer-level incentive effects vary by usage level • Distributed Generation • Reduces DG subsidy • Reduces utility revenue loss from net metering • Economy • Utility fixed-cost revenue (and customer bills) vary less with economic conditions • Weather • Utility fixed-cost revenue (and customer bills) vary less with weather conditions • Low-use customer effect • Potential for high % bill impacts

  23. DG Rates:Description • Some rates may be targeted toward DG customers • Access charge: a $ per month fee based on the DG capacity • Buy all / sell all: DG customers purchase all of their electricity at standard rates, sell DG to the utility at a different rate (that presumably excludes fixed costs) • These can be characterized as discriminatory toward DG customers, since the charges do not apply to all customers • Not true of SFV pricing or declining block rates • Prices may not account for environmental benefits of DG • How to quantify those benefits? • If that benefit is paid to DG customers, the cost must be paid by other ratepayers

  24. DG Rate Scorecard • Conservation • Not applicable • Distributed Generation • Reduces or eliminates DG subsidy • Reduces or eliminates utility revenue loss from net metering • Economy • No effect • Weather • No effect • Low-use customer effect • May reduce low-use customer bills if they are less likely to have DG and a cross-subsidy is removed

  25. Time-differentiated Rates:Description • Some rate designs include rates that vary by time • Static: rates are known in advance, but vary by time of day or season • Time-of-use (TOU) rates • Dynamic: rates vary with system conditions • Real-time pricing • Critical peak pricing • Time-differentiated rates tend to be focused promoting the efficient use of existing resources, or preventing the need to add generating resources (or transmission capacity) in the future • They are not typically focused on addressing conservation or DG issues (so we omit the scorecard)

  26. Summary • Decoupling: • Addresses fixed cost recovery issues due to conservation in a way that minimizes bill impacts (relative to SFV pricing) • Makes the utility whole for revenue loss from DG net metering, but does not address cross-subsidies (still a death spiral!) • LRAMs • Address fixed cost recovery issues from utility-sponsored conservation programs • Is not intended to address DG issues • SFV Pricing • Addresses fixed cost recovery issues due to conservation and DG • Removes DG cross-subsidies • Can have very large bill impacts (bill increase for low-use customers, bill decrease for high-use customers) • DG rates • Can address DG cross-subsidies and utility fixed cost recovery issues • Not intended to address conservation issues

  27. Questions? • If you have questions, please contact Dan Hansen at dghansen@caenergy.com