Superconducting Cavity activities within HIPPI

Superconducting Cavity activities within HIPPI. CARE ‘08 CERN,  2-5 December 2008. Juliette PLOUIN CEA/Saclay. Outline. Objectives of HIPPI - WP3 Cavities parameters Tests Conclusions. Outline. Objectives of HIPPI - WP3 Cavities parameters Tests Conclusions.

linda-bush
Download Presentation

Superconducting Cavity activities within HIPPI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Superconducting Cavity activities within HIPPI CARE ‘08 CERN,  2-5 December 2008 Juliette PLOUIN CEA/Saclay CARE’08,  3 December 2008 

  2. Outline • Objectives of HIPPI - WP3 • Cavities parameters • Tests • Conclusions CARE’08,  3 December 2008 

  3. Outline • Objectives of HIPPI - WP3 • Cavities parameters • Tests • Conclusions CARE’08,  3 December 2008 

  4. Characterization of superconducting (SC) RF structures for use in a pulsed proton linac Investigation of different type of structures ; prepare for comparative assessment Realization of a high power 704 MHz RF test place with cryogenic infrastructure Objectives of the HIPPI-WP3 Objectives : gradient > 7 MV/m with Q > 1010 in the energy range 100-200 Mev, at a construction cost comparable to normal-conducting structures ; development of efficient superconducting structures down to beam energies around 5 Mev ; availability of a 704 MHz high power RF test place for SC cavities. From R. Garoby in CARE kick off meeting – 20,21 Nov. 2003 CARE’08,  3 December 2008 

  5. The HIPPI – WP3 program CARE’08,  3 December 2008 

  6. Elliptic B / b = 0.47 / CEA Elliptic A / b = 0.47 / INFN 3-Spoke / b = 0.48 / FZJ 3 Spoke / b = 0.2 / FZJ 1 Spoke / b = 0.15 / IPNO CH / b = 0.1 / IAP All the cavities have been fabricated... CARE’08,  3 December 2008 

  7. Outline • Objectives of HIPPI - WP3 • Cavity parameters • Tests • Conclusions CARE’08,  3 December 2008 

  8. Design parameters (RF) CARE’08,  3 December 2008 

  9. Miscellaneous Inner magnetic shield (inside the He tank) Outer magnetic shield CARE’08,  3 December 2008 

  10. Mechanical simulations • Calculations of mechanical parameters have been carried out for all the cavities in order to evaluate : • the influence of the Lorentz Force Detuning (LFD) during the tests • the influence of the Helium pressure • Main parameters are : • cavity stiffness [kN/mm] • He pressure sensitivity [Hz/mbar] • Lorentz coefficient KL [Hz/(MV/m)²] (frequency detuning due to Lorentz forces ) • KL depends strongly on the external stiffness, which is not easy to evaluate • Meaningful informations must contain the extreme values of KL (free/fixed ends), and the theoretic curve between these points • Calculations on the dynamical parameters (mechanical modes) have also been performed (EllA, EllB, CH), but their comparison is of poor interest because they strongly depend on the cavity surroundings  not presented here CARE’08,  3 December 2008 

  11. Elliptic B (CEA) Elliptic A (INFN) stiffening rings 1 Spoke (IPNO) 3 Spoke (FZJ) CH (IAP) stiffeners (in red) stiffening rings stiffening ribs – additional stabilization rings Stiffening systems CARE’08,  3 December 2008 

  12. Kext ~ infinite  fixed ends Curves KL/Kext Kext ~ 0 free ends Kext ~ infinite  fixed ends The value for |KL@fixed ends| determines the minimum Lorentz detuning expected on the cavity (external stiffness is infinite) If |DKL(free ends/fixed ends)| is small : the external stiffness is not a critical value to have a small Lorentz detuning If |DKL(free ends/fixed ends)| is high : the external stiffness (stiffness of the tuner) has to be high enough : ~100 kN/mm CARE’08,  3 December 2008 

  13. Mechanical parameters CARE’08,  3 December 2008 

  14. stepping motor Elliptic A : blade tuner, between two parts of the He tank stepping motor Elliptic B : tuner between the He tank and the cavity flange piezo piezo 1 Spoke : tuner between the He tank and the cavity flange CH structure : tuner between the inner cold mass containing the helium and the outer vacuum vessel. piezo piezo Tuners CARE’08,  3 December 2008 

  15. Outline • Objectives of HIPPI - WP3 • Cavities parameters • Tests • Conclusions CARE’08,  3 December 2008 

  16. 3 Spoke 352 MHz Elliptic B T = 1.8 K Quench Low power RF tests - 1 b ~ 0.5 Elliptic A T = 1.9 K CARE’08,  3 December 2008 

  17. 1 Spoke CH 3 Spoke 760 MHz Low power RF tests - 2 b ~ 0.1-0.2 CARE’08,  3 December 2008 

  18. DU is the energy received by a particle while crossing the cavity Eacc = |DU|/(q.Lacc) = Vacc/Lacc Eacc summary Lacc = Ngap*b*l/2 This Vacc/Lcav doesn’t take into account the intermediate space between the cavities depending on the accelerator and cryomodule design. CARE’08,  3 December 2008 

  19. whole coupler Elliptic B 250 kW peak power duty cycle 10 % copper plating of the outer conductor test bench 1 Spoke 20 kW cw RF windows Couplers To be tested and conditionned very soon in the high power 704 MHz RF place at Saclay CARE’08,  3 December 2008 

  20. Outline • Objectives of HIPPI - WP3 • Cavities parameters • Tests • Conclusions CARE’08,  3 December 2008 

  21. Comparative assessments • Most of a the cavities developed in the frame of the program have performances as good as expected. • The work achieved through the HIPPI-WP3 has given very significant elements about the design, the construction, and the experimental tests about SC structures, which can lead to comparative assessment. • A further comparison should involve parameters external to the cavities themselves, and cryogenic technology. • Exhaustive results will be presented in the final HIPPI-WP3 report. The results will be classified in two groups by beta families : b=0.5 & b = 0.1-0.2 CARE’08,  3 December 2008 