1 / 4

VIIRS Cloud Mask (VCM) – IICMO File

VOCCO. VIIRS Cloud Mask (VCM) – IICMO File. Observed Issue:. Pixels that are near the aggregation zone (-999.7) and in cloudy region are not being flagged as cloud. Inaccurately derived ocean color products in these locations are “bleeding” into our results which

lapis
Download Presentation

VIIRS Cloud Mask (VCM) – IICMO File

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VOCCO VIIRS Cloud Mask (VCM) – IICMO File Observed Issue: • Pixels that are near the aggregation • zone (-999.7) and in cloudy region • are not being flagged as cloud. • Inaccurately derived ocean color • products in these locations are • “bleeding” into our results which • are not accurate. Northern Adriatic 05/08/2013 Chlorophyll Aggregation Zone NRL APS

  2. Lt_862 Clear Pixels Aggregation Zone VCM Cloud Mask • Problem areas observed • 2 lines above & below • aggregation zones: • Is this caused by: • gradient test (3x3)? • not being able to execute • default to confident clear • w/ poor quality? • missing input or limitation?

  3. 31 = Day Pixels, High Cloud -999.7 = HILT / Aggregation Zone Mask Quality, Confident Cloudy Problem Area Clear Pixels Aggregation Zone VCM Cloud Mask

  4. NRL current handling of VCM issue NRL APS VCM w/ Issue NRL APS Expanded HILT mask (-999.7 Agg. Zone) where VCM Cloud Mask Quality = 0 (Poor) Note: In this case no other cloud test are performed Why not set to low and continue other test? How does this relate to aggregation zone? VCM ATBD 474-00033 4/22/2011