Prostate Cryoablation Technique

Prostate Cryoablation Technique. Four Steps. Ultrasound Capture Probe Planning Probe Placement Freeze / Thaw Cycles. Step #1 Ultrasound Capture. Place Foley Catheter, fill bladder with saline

lantz
Download Presentation

Prostate Cryoablation Technique

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Prostate Cryoablation Technique

  2. Four Steps • Ultrasound Capture • Probe Planning • Probe Placement • Freeze / Thaw Cycles

  3. Step #1 Ultrasound Capture • Place Foley Catheter, fill bladder with saline • Align ultrasound probe, center image, assure that plane of urethra and plane of transducer is parallel • Urethra should stay on centerline as you move ultrasound cradle from base to apex • Measure volume (height, width, length)

  4. Transverse Mid Gland Ultrasound

  5. Pubis *ES Foley * AnalSphincter Periprostatic Fat and Fascia of capsule Sagittal Ultrasound Anatomy

  6. Ultrasound Capture

  7. Step #2Cryoprobe & Temprobe Planning • Outline the prostate margin (stay outside the capsule for high risk disease where capsular disease is suspected) • Outline urethra (allow a large margin for salvage cases) • Outline rectal wall

  8. Cryoprobe & Temprobe Planning Software • Outline • Margin • Urethra • Rectal

  9. Cryoprobe & Temprobe Planning Software • Cryoguide placement • logic recommends: • - Cryoprobe • - Temprobe Add/Subtract Probes Check measurements

  10. <2cm < 1cm .> 0.5 cm CryoProbeTM Placement Logic •  1 cm from the capsule •  2 cm apart • > 0.5 cm from rectal wall • > 0.5 cm from urethral wall -40 C: D= 1.96 cm L= 3.85 cm

  11. CryoProbe and Temprobes placement can be verified with software measurement function Cryoprobe & Temprobe Planning Software

  12. 2 1 6 5 3 4 Step # 3Probe Placement Sequence Placement Sequence Anterior - CryoProbes 1 & 2 Midline - Ant, ES, Apex, DEN TempProbes Posterior Medial - CryoProbes 5 & 6 Posterior Lateral - CryoProbes 3 & 4 Lateral - RNVB, LNVB TempProbes Urethra - Urethral Warming Catheter