Sample Concentrator LSCO-A10 accelerates the concentration of samples by blowing nitrogen gas at the rate of 15 L/min. It comes with a microprocessor controller which controls the temperature of high-purity aluminium when the equipment is in operation. The models have provisions of concentrating around 3 to 24 samples at a time.

Download Presentation

Sample-Concentrator-LSCO-A1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sample Concentrator LSCO-A1 Series www.labtron.com info@labtron.com

  2. Sample Concentrator Sample Concentrator LSCO-A1 series Sample Concentrator LSCO-A1 series accelerates the concentration of samples by blowing nitrogen gas at the rate of 15 L/min. It comes with a microprocessor controller which con- trols the temperature of high-purity aluminium when the equipment is in operation. The models have provisions of concentrating around 3 to 24 samples at a time. Features Microprocessor based PID controller High-purity aluminium as heat conducting medium Precised temperature control Adjustable airflow rate Large number of samples can be blowed at a time Individualistic blowing of sample Can be easily operated Applications Sample Concentrator is used for sample preparation, drug screening, hormone assays, chromatographic analysis and scintillation counting.

  3. Sample Concentrator Specifications Model no. LSCO-A10 LSCO-A11 Number of samples 3 to 24 wells 3 to 24 wells Nitrogen Flow Rate 15 L/min 15 L/min 0.02MPa 0.02 MPa (Gas needle≤16pcs) 0.05MPa (Gas needle>16pcs) (Gas needle≤16pcs) 0.05MPa (Gas needle>16pcs) Nitrogen Pressure 2 1 Block Quantity Room temp. +5 0C to 160 0C Room temp. +5 0C to 160 0C Temperature Control Range 150 mm 150 mm Needle length ≤±0.5 0C ≤±0.5 0C Temp. uniformity ±0.5 0C (at 40 0C) ±10C (at 120 0C) ±0.5 0C (at 40 0C) ±10C (at 120 0C) Temp. accuracy Display accuracy 0.1 0C 0.1 0C ≤15 min ≤15 min Heating time (from 25 0C to 160 0C) (from 25 0C to 160 0C) Timing range 1 min-99 h 59 min 1 min-99 h 59 min AC220 V or AC110 V, 50/60 Hz AC220 V or AC110 V, 50/60 Hz Voltage 500 W Power Consumption 300 W 260x220x475 mm Dimension 260x220x450 mm 7.5 kg Weight 7 kg

  4. Sample Concentrator Optional Accessories Block no. Capacity Diameter of tubes SCB-01 10 mm 24 SCB-02 12 mm 24 SCB-03 13 mm 24 SCB-04 15 mm 16 SCB-05 16 mm 16 SCB-06 19 mm 12 SCB-07 20 mm 12 SCB-08 26 mm 8 SCB-09 28 mm 4 SCB-10 40 mm 3 SCB-11 1.5 ml (centrifuge tube) 24 SCB-12 2.0 ml (centrifuge tube) 24